(224) 955-1644
Hammond ManufacturingAuthorized partner store
Hammond 374XP 141 VA potted plate and filament power transformer in black powder-painted drawn steel case

Hammond 374XP 141 VA 750V C.T. Potted Plate & Filament Transformer

Hammond Manufacturing|

MPN: 374XP

|

UPC: 623980024448

In Stock
$449.69

Ships from and sold by A5 IT

Ground Shipping · $21.16Arrives by Monday, Oct 26
Order within 2h 49m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 141 VA rating with 750V C.T. @ 127 mA high voltage (plate) secondary
  • Two filament windings: 5V C.T. @ 3A and 6.3V C.T. @ 5A
  • Universal primary: 100, 110, 120, 200, 220, 230, 240 VAC at 50/60 Hz
  • 50 VAC bias tap on the high voltage secondary (C.T. grounded)
  • Drawn steel case, fully potted in epoxy, black powder paint finish
  • Faraday copper primary shield and concentric windings for low stray field and low noise
  • 1/4-20 threaded insert mounting, hardware included; 4.25 x 5.00 x 5.44 in (108 x 127 x 138 mm)
  • c UL us recognized (E207860); RoHS and REACH compliant

The 374XP is a 141 VA potted high voltage (plate) and filament power transformer from the 300P Series, built for designers and builders of equipment that need a plate supply and heater windings from one universal-primary transformer. It supplies 750V C.T. at 127 mA with a 5V C.T. 3 A filament and a 6.3V C.T. 5 A filament; its part drawing documents lead colours, excitation current, no-load voltages and winding resistances.

The transformer is enclosed in a drawn steel case and completely potted in epoxy, finished in black powder paint to match the 1650P series of potted output transformers. Windings are concentric wound for low stray field and low noise, and a Faraday copper primary shield reduces capacitive coupling from the primary, attenuating higher frequency current coupling to the secondaries; the shield is internally grounded to the end bell.

The primary accepts 100, 110, 120, 200, 220, 230 or 240 VAC at 50/60 Hz. The 750V C.T. high voltage secondary is rated 127 mA and includes a 50 VAC bias tap (measured with the high voltage C.T. grounded), and the unit also provides a 5V C.T. @ 3A filament winding and a 6.3V C.T. @ 5A filament winding. It can be run full wave bridge or full wave C.T. The series is hipot tested at 2,000 VAC and is c UL us recognized (E207860), and the part drawing lists a primary-to-secondary hipot of 2500V, 60Hz for 1 second.

Listed dimensions are A 4.25 in (108 mm), B 5.00 in (127 mm) and C 5.44 in (138 mm). The 374XP mounts using 1/4-20 threaded inserts, mounting hardware is included, and the shipping weight is 5.6 lbs (2.54 kg). All leads exit 8 in minimum and are stripped 0.5 in.

Ideal For

  • 750V C.T. plate (B+) supply with 50 VAC bias tap
  • Dual filament supply: 5V C.T. @ 3A and 6.3V C.T. @ 5A
  • Full wave bridge or full wave C.T. rectified power supplies
  • Builds matched to 1650P potted output transformers
  • Equipment needing 100-240 VAC, 50/60 Hz input

Wiring

Lead LengthAll leads 8" out min., stripped .5"
Shield LeadGRY
Bias Tap LeadVIO 50V
Filament #1 LeadsYEL / YEL/BLK (C.T.) / YEL, 5VCT 3A
Filament #2 LeadsGRN / GRN/YEL (C.T.) / GRN, 6.3VCT 5A
Primary Leads (Winding 1)0V BRN, 100V BRN/YEL, 110V BLU/YEL, 120V BLU
Primary Leads (Winding 2)0V WHT, 100V WHT/BLK, 110V BLK/RED, 120V BLK
Secondary Leads (High Voltage)RED 375V / RED/YEL 0V (C.T.) / RED 375V, 127mA

Mounting

Mounting HardwareIncluded
Mounting Threaded Insert1/4-20
Mounting Inserts (Drawing)1/4-20 x 0.500" deep inserts, 4 places

Overview

Series300P Series - Potted High Voltage (Plate) & Filament
DescriptionTransformer, high voltage & filament, 141VA, 750V C.T. @ 127ma., 300P Series
Short DescriptionMULTI-TAP PRI,141 VA, 50/60 HZ

Dimensions

Dimension A4.25 in (108 mm)
Dimension B5.00 in (127 mm)
Dimension C5.44 in (138 mm)
Dimension A (Drawing)4.250" ±0.063
Dimension B (Drawing)5.000" ±0.063
Dimension C (Drawing)4.500" ±0.063
Dimension D (Drawing)3.375" ±0.063
Dimension E (Drawing)4.250" ±0.063
Dimension F (Drawing)1.500" ±0.063
Dimension H (Drawing, 2 Places)0.500" ±0.015

Electrical

WindingsConcentric wound for low stray field and low noise
Primary VACUniversal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz
Primary ShieldFaraday copper electrostatic shield, internally grounded to the end bell
Filament #1 VAC5V C.T. @ 3A
Filament #2 VAC6.3V C.T. @ 5A
Power Rating (VA)141
Hipot Test (Series)2,000 VAC
Rectifier ConfigurationCan be run full wave bridge or full wave C.T.
AC High Voltage Secondary R.M.S.750V C.T. @ 127ma.
Bias Tap On High Voltage Secondary W/ C.T. Grounded VAC50

Identifiers

UPC623980024448
UNSPSC39121301
DrawingPlate & Filament Potted Power TX., DWG. NO. 374XP, Rev. 0, released 01/13/25
Part Number374XP

Test Data (Drawing)

Excitation Current (Iex)140mA Max. @ 120V, 60Hz, WHT - BLK
Hipot, Primary - Secondary2500V, 60Hz, 1 SEC
DC Resistance BRN - BLU @ 20°C4.825 ±20%
DC Resistance GRN - GRN @ 20°C0.054 ±20%
DC Resistance RED - RED @ 20°C182.0 ±20%
DC Resistance WHT - BLK @ 20°C4.469 ±20%
DC Resistance YEL - YEL @ 20°C0.051 ±20%
Sec. No-Load Voltage GRN - GRN (@ 120V, 60Hz, WHT - BLK)6.945V ±2%
Sec. No-Load Voltage RED - RED (@ 120V, 60Hz, WHT - BLK)808.7V ±2%
Sec. No-Load Voltage YEL - YEL (@ 120V, 60Hz, WHT - BLK)5.402V ±2%
Sec. No-Load Voltage RED/YEL - VIO (@ 120V, 60Hz, WHT - BLK)50.16V ±2%
Sec. No-Load Voltage GRN - GRN/YEL = GRN/YEL - GRN (@ 120V, 60Hz, WHT - BLK)3.473V ±2%
Sec. No-Load Voltage RED - RED/YEL = RED/YEL - RED (@ 120V, 60Hz, WHT - BLK)404.4V ±2%
Sec. No-Load Voltage YEL - YEL/BLK = YEL/BLK - YEL (@ 120V, 60Hz, WHT - BLK)2.701V ±2%

Packaging & Shipping

Shipping Weight5.6 lbs (2.54 kg)

Construction & Finish

FinishBlack powder paint (matches 1650P series potted output transformers)
EnclosureDrawn steel case, completely potted in epoxy

Compliance & Certifications

RoHS CompliantYes
REACH CompliantYes
Safety Recognitionc UL us recognized (E207860)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What input voltages does the 374XP accept?▾

It has a universal primary rated for 100, 110, 120, 200, 220, 230 and 240 VAC at 50/60 Hz.

What secondary windings does the 374XP provide?▾

A 750V C.T. @ 127 mA high voltage secondary with a 50 VAC bias tap (C.T. grounded), plus a 5V C.T. @ 3A filament and a 6.3V C.T. @ 5A filament.

How big is the 374XP and how does it mount?▾

Listed dimensions are A 4.25 in (108 mm), B 5.00 in (127 mm) and C 5.44 in (138 mm). It mounts with 1/4-20 threaded inserts and mounting hardware is included.

Can it be used with a full wave bridge rectifier?▾

Yes. Units in this series can be run full wave bridge or full wave C.T.

What certifications does the 374XP carry?▾

The 300P Series is c UL us recognized (E207860), and this part is listed as RoHS and REACH compliant.

What are the factory test limits for the 374XP?▾

The part drawing lists excitation current of 140mA Max. at 120V, 60Hz, a no-load high voltage of 808.7V ±2% RED to RED, and a 2500V, 60Hz, 1 second primary-to-secondary hipot.