Hammond 370HXP 180 VA 550V C.T. Potted Plate & Filament Transformer
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 180 VA rating with 550V C.T. @ 230 mA high voltage (plate) secondary
- Two filament windings: 5V C.T. @ 3A and 6.3V C.T. @ 6A
- Universal primary: 100, 110, 120, 200, 220, 230, 240 VAC at 50/60 Hz
- 50 VAC bias tap on the high voltage secondary (C.T. grounded)
- Drawn steel case, fully potted in epoxy, black powder paint finish
- Faraday copper primary shield and concentric windings for low stray field and low noise
- 1/4-20 threaded insert mounting, hardware included; 4.25 x 5.00 x 5.44 in (108 x 127 x 138 mm)
- c UL us recognized (E207860); RoHS and REACH compliant
The 370HXP is a 180 VA potted high voltage (plate) and filament power transformer from the 300P Series, built for designers and builders of equipment that need a plate supply and heater windings from one universal-primary transformer. It is the highest-current 550V C.T. model in the series, rated 230 mA on the plate winding, with a 5V C.T. 3 A filament and a 6.3V C.T. 6 A filament.
The transformer is enclosed in a drawn steel case and completely potted in epoxy, finished in black powder paint to match the 1650P series of potted output transformers. Windings are concentric wound for low stray field and low noise, and a Faraday copper primary shield reduces capacitive coupling from the primary, attenuating higher frequency current coupling to the secondaries; the shield is internally grounded to the end bell.
The primary accepts 100, 110, 120, 200, 220, 230 or 240 VAC at 50/60 Hz. The 550V C.T. high voltage secondary is rated 230 mA and includes a 50 VAC bias tap (measured with the high voltage C.T. grounded), and the unit also provides a 5V C.T. @ 3A filament winding and a 6.3V C.T. @ 6A filament winding. It can be run full wave bridge or full wave C.T. The series is hipot tested at 2,000 VAC and is c UL us recognized (E207860).
Listed dimensions are A 4.25 in (108 mm), B 5.00 in (127 mm) and C 5.44 in (138 mm). The 370HXP mounts using 1/4-20 threaded inserts, mounting hardware is included, and the shipping weight is 7.6 lbs (3.45 kg).
Ideal For
- 550V C.T. plate (B+) supply with 50 VAC bias tap
- Dual filament supply: 5V C.T. @ 3A and 6.3V C.T. @ 6A
- Full wave bridge or full wave C.T. rectified power supplies
- Builds matched to 1650P potted output transformers
- Equipment needing 100-240 VAC, 50/60 Hz input
Mounting
| Mounting Hardware | Included |
| Mounting Threaded Insert | 1/4-20 |
Overview
| Series | 300P Series - Potted High Voltage (Plate) & Filament |
| Description | Transformer, high voltage & filament, 180VA, 550V C.T. @ 230ma., 300P Series |
| Short Description | MULTI TAP PRI, 50/60HZ, 180VA |
Dimensions
| Dimension A | 4.25 in (108 mm) |
| Dimension B | 5.00 in (127 mm) |
| Dimension C | 5.44 in (138 mm) |
Electrical
| Windings | Concentric wound for low stray field and low noise |
| Primary VAC | Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz |
| Primary Shield | Faraday copper electrostatic shield, internally grounded to the end bell |
| Filament #1 VAC | 5V C.T. @ 3A |
| Filament #2 VAC | 6.3V C.T. @ 6A |
| Power Rating (VA) | 180 |
| Hipot Test (Series) | 2,000 VAC |
| Rectifier Configuration | Can be run full wave bridge or full wave C.T. |
| AC High Voltage Secondary R.M.S. | 550V C.T. @ 230ma. |
| Bias Tap On High Voltage Secondary W/ C.T. Grounded VAC | 50 |
Identifiers
| UPC | 623980024394 |
| UNSPSC | 39121301 |
| Part Number | 370HXP |
Packaging & Shipping
| Shipping Weight | 7.6 lbs (3.45 kg) |
Construction & Finish
| Finish | Black powder paint (matches 1650P series potted output transformers) |
| Enclosure | Drawn steel case, completely potted in epoxy |
Compliance & Certifications
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| Safety Recognition | c UL us recognized (E207860) |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What input voltages does the 370HXP accept?▾
It has a universal primary rated for 100, 110, 120, 200, 220, 230 and 240 VAC at 50/60 Hz.
What secondary windings does the 370HXP provide?▾
A 550V C.T. @ 230 mA high voltage secondary with a 50 VAC bias tap (C.T. grounded), plus a 5V C.T. @ 3A filament and a 6.3V C.T. @ 6A filament.
How big is the 370HXP and how does it mount?▾
Listed dimensions are A 4.25 in (108 mm), B 5.00 in (127 mm) and C 5.44 in (138 mm). It mounts with 1/4-20 threaded inserts and mounting hardware is included.
Can it be used with a full wave bridge rectifier?▾
Yes. Units in this series can be run full wave bridge or full wave C.T.
What certifications does the 370HXP carry?▾
The 300P Series is c UL us recognized (E207860), and this part is listed as RoHS and REACH compliant.
Related Products
Save 52%370FXP — Transformer, high voltage & filament, 141VA, 550V C.T. @ 173ma., 300P Series
Hammond Manufacturing · 370FXP
Save 52%370XP — Transformer, high voltage & filament, 41VA, 480V C.T. @ 46ma., 300P Series
Hammond Manufacturing · 370XP
Save 52%370EXP — Transformer, high voltage & filament, 119VA, 550V C.T. @ 144ma., 300P Series
Hammond Manufacturing · 370EXP
Save 52%372FXP — Transformer, high voltage & filament, 150VA, 600V C.T. @ 173ma., 300P Series
Hammond Manufacturing · 372FXP
Save 52%370DXP — Transformer, high voltage & filament, 86VA, 550V C.T. @ 104ma., 300P Series
Hammond Manufacturing · 370DXP