Hammond 370DAZ 76VA 520V CT Horizontal Plate & Filament Transformer
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 76VA rating with 520V C.T. @ 104ma. RMS high voltage (plate) secondary
- Filament winding: 6.3V C.T. @ 3.5A
- 50 VAC bias tap on the high voltage secondary C.T.
- Faraday copper primary shield and concentric windings for low stray field and low noise
- Horizontal ("Z") mounting; black powder paint finish
- Hipot tested at 2,000 VAC; CSA certified (209651); REACH and RoHS compliant
The 370DAZ is a high voltage (plate) and filament power transformer from the 300 Series, rated 76VA. It is aimed at builders, restorers and OEM engineers designing vacuum tube equipment who need a single transformer to supply the B+ plate winding and the tube heater winding.
The high voltage secondary is 520V C.T. @ 104ma. RMS, with a 50 VAC bias tap on the high voltage secondary (with the C.T. grounded). The transformer also provides a single filament winding of 6.3V C.T. @ 3.5A. The universal primary accepts 100, 110, 120, 200, 220, 230 or 240 VAC at 50/60 Hz; the units are designed to operate with both primary windings engaged. The 370DAZ can be run full wave bridge or full wave C.T.
Construction follows the series design: a Faraday copper primary shield (internally grounded to the end bell) reduces capacitive coupling from the primary and attenuates higher frequency current coupling to the secondaries, and concentric winding gives low stray field and low noise. The black powder paint finish matches the 1650 series of output transformers. Units are hipot tested at 2,000 VAC and are CSA certified (209651).
The 370DAZ uses the horizontal ("Z") mounting style. Published dimensions are A 2.25 in (57 mm), B 2.81 in (71 mm), C 3.50 in (89 mm), D 2.50 in (64 mm), F 2.44 in (62 mm), G 1.30 in (33 mm), H 3.38 in (86 mm), J 2.81 in (71 mm). Shipping weight is 2.7 lbs (1.22 kg). It is listed as REACH and RoHS compliant.
Ideal For
- Vacuum tube audio amplifier power supplies
- Tube preamp and amplifier builds
- Replacement or upgrade of 200 Series transformers
Overview
| Series | 300 Series - High Voltage (Plate) & Filament, 39 VA to 940 VA |
| Product Type | Transformer, high voltage & filament |
| Short Description | MULTI-TAP PRI, 76 VA, 50/60 HZ |
Dimensions
| Dimension A | 2.25 in (57 mm) |
| Dimension B | 2.81 in (71 mm) |
| Dimension C | 3.50 in (89 mm) |
| Dimension D | 2.50 in (64 mm) |
| Dimension F | 2.44 in (62 mm) |
| Dimension G | 1.30 in (33 mm) |
| Dimension H | 3.38 in (86 mm) |
| Dimension J | 2.81 in (71 mm) |
Electrical
| Frequency | 50/60 Hz |
| Hipot Test | 2,000 VAC |
| Primary VAC | Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz |
| Filament #1 VAC | 6.3V C.T. @ 3.5A |
| Power Rating (VA) | 76 |
| Primary Wiring Note | Designed to operate with BOTH primary windings engaged |
| Rectifier Configuration | Full wave bridge or full wave C.T. |
| AC High Voltage Secondary (RMS) | 520V C.T. @ 104ma. |
| Bias Tap On High Voltage Secondary, C.T. Grounded VAC | 50 |
Identifiers
| UPC | 623980007946 |
| UNSPSC | 39121301 |
| Part Number | 370DAZ |
Rack Mounting
| Mounting Style | Horizontal ("Z") |
Packaging & Shipping
| Shipping Weight | 2.7 lbs (1.22 kg) |
Construction & Finish
| Finish | Black powder paint (matches 1650 series output transformers) |
| Windings | Concentric wound for low stray field and low noise |
| Primary Shield | Faraday copper electrostatic shield, internally grounded to the end bell |
Compliance & Certifications
| CSA Certified | Yes (209651) |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What are the output ratings of the 370DAZ?▾
It is rated 76VA with a 520V C.T. @ 104ma. RMS high voltage secondary and a 6.3V C.T. @ 3.5A filament winding.
Does it have a bias supply?▾
Yes, there is a 50 VAC bias tap on the high voltage secondary with the C.T. grounded.
Can I use a bridge rectifier?▾
Yes, 300 Series units can be run full wave bridge or full wave C.T.
How is the 370DAZ mounted?▾
It uses the horizontal ("Z") mounting style; dimensions A to J are published in the specs.
Is it safety certified?▾
The 300 Series is CSA certified (209651) and hipot tested at 2,000 VAC; this part is also REACH and RoHS compliant.
Related Products
Save 52%370DAX — Transformer, high voltage & filament, 76VA, 520V C.T. @ 104ma., 300 Series
Hammond Manufacturing · 370DAX
Save 52%370DX — Transformer, high voltage & filament, 86VA, 550V C.T. @ 104ma., 300 Series
Hammond Manufacturing · 370DX
Save 52%370CX — Transformer, high voltage & filament, 59VA, 550V C.T. @ 75ma., 300 Series
Hammond Manufacturing · 370CX
Save 52%370EX — Transformer, high voltage & filament, 119VA, 550V C.T. @ 144ma., 300 Series
Hammond Manufacturing · 370EX
Save 52%370CAX — Transformer, high voltage & filament, 66VA, 500V C.T. @ 81ma., 300 Series
Hammond Manufacturing · 370CAX