- 188VA rating with 450V C.T. @ 300 ma. RMS high voltage (plate) secondary
- Filament windings: 5V C.T. @ 3A, 6.3V C.T. @ 6A
- 50 VAC bias tap on the high voltage secondary C.T.
- Faraday copper primary shield and concentric windings for low stray field and low noise
- Horizontal ("Z") mounting; black powder paint finish
- Hipot tested at 2,000 VAC; CSA certified (209651); REACH and RoHS compliant
The 369KZ is a high voltage (plate) and filament power transformer from the 300 Series, rated 188VA. It is aimed at builders, restorers and OEM engineers designing vacuum tube equipment who need a single transformer to supply the B+ plate winding and 2 separate filament windings.
The high voltage secondary is 450V C.T. @ 300 ma. RMS, with a 50 VAC bias tap on the high voltage secondary (with the C.T. grounded). The transformer also provides 2 filament windings: #1 5V C.T. @ 3A; #2 6.3V C.T. @ 6A. The universal primary accepts 100, 110, 120, 200, 220, 230 or 240 VAC at 50/60 Hz; the units are designed to operate with both primary windings engaged. The 369KZ can be run full wave bridge or full wave C.T.
Construction follows the series design: a Faraday copper primary shield (internally grounded to the end bell) reduces capacitive coupling from the primary and attenuates higher frequency current coupling to the secondaries, and concentric winding gives low stray field and low noise. The black powder paint finish matches the 1650 series of output transformers. Units are hipot tested at 2,000 VAC and are CSA certified (209651).
The 369KZ uses the horizontal ("Z") mounting style. Published dimensions are A 2.50 in (64 mm), B 3.12 in (79 mm), C 4.25 in (108 mm), D 2.06 in (52 mm), F 2.69 in (68 mm), G 2.06 in (52 mm), H 3.75 in (95 mm), J 3.12 in (79 mm). It is listed as REACH and RoHS compliant.
The part drawing specifies 100/110/120V primary taps on each primary winding, a 450VCT 300mA high voltage winding with a 50V tap, a 5V 3A winding (revision 1 removed the C.T. from the 5V winding) and a 6.3VCT 6A winding, with all leads 8" out minimum. The drawing lists a 2500V, 60Hz, 1 second primary-to-secondary hipot and marks the unit Made in Canada.
Ideal For
- Vacuum tube audio amplifier power supplies
- Tube preamp and amplifier builds
- Replacement or upgrade of 200 Series transformers
Overview
| Series | 300 Series - High Voltage (Plate) & Filament, 39 VA to 940 VA |
| Product Type | Transformer, high voltage & filament |
| Short Description | TUBE POWER TRANS |
Dimensions
| Dimension A | 2.50 in (64 mm) |
| Dimension B | 3.12 in (79 mm) |
| Dimension C | 4.25 in (108 mm) |
| Dimension D | 2.06 in (52 mm) |
| Dimension F | 2.69 in (68 mm) |
| Dimension G | 2.06 in (52 mm) |
| Dimension H | 3.75 in (95 mm) |
| Dimension J | 3.12 in (79 mm) |
Electrical
| Frequency | 50/60 Hz |
| Hipot Test | 2,000 VAC |
| Primary VAC | Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz |
| Filament #1 VAC | 5V C.T. @ 3A |
| Filament #2 VAC | 6.3V C.T. @ 6A |
| Power Rating (VA) | 188 |
| Excitation Current | 221mA max @ 120V, 60Hz |
| Primary Wiring Note | Designed to operate with BOTH primary windings engaged |
| 5V Winding (Drawing) | 5V 3A; Rev. 1 removed CT from 5V winding |
| 6.3V Winding (Drawing) | 6.3VCT 6A |
| Primary Taps (Drawing) | 100V / 110V / 120V on each primary winding |
| Rectifier Configuration | Full wave bridge or full wave C.T. |
| Secondary No-Load Voltage, 5V | 5.280V ±2% |
| High Voltage Winding (Drawing) | 450VCT 300mA with 50V tap |
| AC High Voltage Secondary (RMS) | 450V C.T. @ 300 ma. |
| DC Resistance @ 20°C, 5V YEL-YEL | 0.043 ±20% |
| DC Resistance @ 20°C, HV RED-RED | 36.87 ±20% |
| Secondary No-Load Voltage, HV Full | 474.2V ±2% |
| Secondary No-Load Voltage, HV Half | 237.1V ±2% |
| DC Resistance @ 20°C, 6.3V GRN-GRN | 0.029 ±20% |
| Secondary No-Load Voltage, Bias Tap | 52.80V ±2% |
| DC Resistance @ 20°C, Primary BRN-BLU | 3.328 ±20% |
| DC Resistance @ 20°C, Primary WHT-BLK | 3.075 ±20% |
| Bias Tap On High Voltage Secondary, C.T. Grounded VAC | 50 |
Identifiers
| UPC | 623980474670 |
| UNSPSC | 39121301 |
| Part Number | 369KZ |
| Country Of Origin | Canada |
Rack Mounting
| Mounting Style | Horizontal ("Z") |
Construction & Finish
| Leads | All leads 8" out min. |
| Finish | Black powder paint (matches 1650 series output transformers) |
| Windings | Concentric wound for low stray field and low noise |
| Primary Shield | Faraday copper electrostatic shield, internally grounded to the end bell |
Compliance & Certifications
| CSA Certified | Yes (209651) |
| RoHS Compliant | Yes |
| Hipot (Drawing) | Primary - Secondary 2500V, 60Hz, 1 sec |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What are the output ratings of the 369KZ?▾
It is rated 188VA with a 450V C.T. @ 300 ma. RMS high voltage secondary and filament windings of 5V C.T. @ 3A, 6.3V C.T. @ 6A.
Does it have a bias supply?▾
Yes, there is a 50 VAC bias tap on the high voltage secondary with the C.T. grounded.
Can I use a bridge rectifier?▾
Yes, 300 Series units can be run full wave bridge or full wave C.T.
How is the 369KZ mounted?▾
It uses the horizontal ("Z") mounting style; dimensions A to J are published in the specs.
Is it safety certified?▾
The 300 Series is CSA certified (209651) and hipot tested at 2,000 VAC; this part is also REACH and RoHS compliant.
Related Products
Save 52%369KX — Transformer, high voltage & filament, 188VA, 450V C.T. @ 300ma., 300 Series
Hammond Manufacturing · 369KX
Save 52%370AX — Transformer, high voltage & filament, 44VA, 480V C.T. @ 58ma., 300 Series
Hammond Manufacturing · 370AX
Save 52%369JX — Transformer, high voltage & filament, 50VA, 500V C.T. @ 69ma., 300 Series
Hammond Manufacturing · 369JX
Save 52%370BX — Transformer, high voltage & filament, 55VA, 550V C.T. @ 58ma., 300 Series
Hammond Manufacturing · 370BX
Save 52%369HX — Transformer, high voltage & filament, 120VA, 450V C.T. @ 150ma., 300 Series
Hammond Manufacturing · 369HX