Hammond 284X 329VA 1200V C.T. Transformer, Three Filaments
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 329 VA rating with 1200V C.T. @ 230ma high voltage secondary
- Filament windings: 5V @ 3A, 6.3V @ 3A and 6.3V @ 3A
- Primary 115/125 VAC, 60 Hz (North American line)
- Enclosed, 4 hole, vertical ("X") chassis mount, minimum 6" leads
- Run full wave bridge or full wave C.T.
- Class A insulation (105 degrees C), Hi-Pot tested at 2,000V RMS
- CSA certified (209651); REACH and RoHS compliant
The 284X is a 329 VA high voltage transformer with a 115/125 VAC primary and a 1200V centre-tapped plate secondary rated 230 mA. It carries three filament windings: 5V at 3A, 6.3V at 3A and a second 6.3V at 3A. It is intended for high-voltage tube power supplies running from a 60 Hz North American line, including sites where line voltage runs closer to 125V.
Mechanically, the 284X is an enclosed, 4 hole, chassis mount design in the vertical ("X") mounting style, with minimum 6" long leads. Ordering-table dimensions are A 3.75 in (95 mm), B 4.50 in (114 mm), C 4.56 in (116 mm), D 3.00 in (76 mm) and F 3.31 in (84 mm), and the mounting slots measure 0.20 x 0.38 in (5 x 10 mm). The shipping weight is 4.9 lbs (2.22 kg).
Hammond states that 200 Series units can be run full wave bridge or full wave C.T., use Class A insulation (105 degrees C), are Hi-Pot tested at 2,000V RMS and are CSA certified (209651). The part is listed as REACH compliant and RoHS compliant.
The primary is rated 115/125 VAC at 60 Hz. The series wiring notes describe using the White and Gray wires (taping the Black) for 115 VAC input, or the White and Black wires (taping the Gray) where roughly 125V line voltage produces too high a secondary voltage. Never connect power to both the Gray and Black wires; the manufacturer warns this will instantly destroy the transformer.
Ideal For
- 1200V C.T. high voltage tube supplies
- Supplies needing three filament windings
- Installations on 115V or 125V lines
- Full wave bridge or C.T. rectifier supplies
Overview
| Series | 200 Series - High Voltage (Plate) & Filament |
| Part Number | 284X |
| Long Description | Transformer, high voltage, 329VA, primary 115/125VAC, HV secondary 1200V C.T. @ 230ma. |
| Short Description | POWER TX |
Dimensions
| Dimension A | 3.75 in (95 mm) |
| Dimension B | 4.50 in (114 mm) |
| Dimension C | 4.56 in (116 mm) |
| Dimension D | 3.00 in (76 mm) |
| Dimension F | 3.31 in (84 mm) |
Electrical
| Filament #1 | 5V @ 3A |
| Filament #2 | 6.3V @ 3A |
| Filament #3 | 6.3V @ 3A |
| Hi-Pot Test | 2,000V RMS |
| Power Rating | 329 VA |
| Primary Voltage | 115/125 VAC |
| Primary Frequency | 60 Hz |
| Rectifier Configuration | Full wave bridge or full wave C.T. |
| AC High Voltage Secondary (RMS) | 1200V C.T. @ 230ma. |
Identifiers
| UPC | 623980142968 |
| UNSPSC | 39121301 |
Rack Mounting
| Mounting Type | Vertical ("X"), 4 hole chassis mount |
| Mounting Slot G | 0.20 x 0.38 in (5 x 10 mm) |
Packaging & Shipping
| Shipping Weight | 4.9 lbs (2.22 kg) |
Construction & Finish
| Lead Length | Minimum 6 in |
| Construction | Enclosed |
| Insulation Class | Class A (105 degrees C) |
Compliance & Certifications
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| CSA Certification | CSA certified (209651) |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What are the output windings of the 284X?▾
A 1200V C.T. @ 230ma high voltage secondary plus filament windings of 5V @ 3A, 6.3V @ 3A and 6.3V @ 3A.
What input does the 284X require?▾
The primary is rated 115/125 VAC at 60 Hz. For 50/60 Hz or universal primaries, Hammond points to its 300 Series.
Can it be used with a bridge rectifier?▾
Yes. The series data states units can be run full wave bridge or full wave C.T.
How is the 284X mounted?▾
It is an enclosed, 4 hole, vertical ("X") chassis mount unit with 0.20 x 0.38 in (5 x 10 mm) mounting slots and minimum 6" leads.
What certifications and ratings apply?▾
Class A insulation (105 degrees C), Hi-Pot test of 2,000V RMS, CSA certified (209651), and listed as REACH and RoHS compliant.
How heavy is the 284X?▾
The shipping weight is 4.9 lbs (2.22 kg).
Related Products
Save 52%266R24 — Power transformer, chassis mount, 192VA, 24V @ 8A or 12V @ 16A, 266 Series
Hammond Manufacturing · 266R24
Save 52%266N48 — Power transformer, chassis mount, 192VA, 48V @ 4A or 24V @ 8A, 266 Series
Hammond Manufacturing · 266N48
Save 52%266N24 — Power transformer, chassis mount, 96VA, 24V @ 4A or 12V @ 8A, 266 Series
Hammond Manufacturing · 266N24
Save 52%266LA25 — Power transformer, chassis mount, 50.4VA, 25.2V C.T. @ 2A or -, 266 Series
Hammond Manufacturing · 266LA25
Save 52%266LA12 — Power transformer, chassis mount, 24VA, 12V @ 2A or 6V @ 4A, 266 Series
Hammond Manufacturing · 266LA12