(224) 955-1644
Hammond ManufacturingAuthorized partner store
272BX 95 VA high voltage plate and filament transformer, vertical (X) enclosed chassis mount, 600V C.T. @ 115mA secondary

Hammond 272BX 95 VA Plate Transformer, 600V C.T. 115mA

Hammond Manufacturing|

MPN: 272BX

|

UPC: 623980276007

In Stock
$81.44

Ships from and sold by A5 IT

Ground Shipping · $20.38Arrives by Monday, Oct 26
Order within 3h 43m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 95 VA rating; 600V C.T. @ 115mA RMS high voltage (plate) secondary
  • 115 VAC primary, 60 Hz
  • 115 VAC via white/gray leads or roughly 125V line via white/black leads, per series notes
  • Filament windings: 5V @ 2A and 6.3V @ 3A
  • Enclosed, 4 hole, chassis mount in the vertical (X) style, 2.50 in (64 mm) x 3.25 in (83 mm)
  • Runs full wave bridge or full wave C.T.
  • Class A insulation (105 degrees C), 2,000V RMS hi-pot test, minimum 6 in leads
  • CSA certified (209651); RoHS and REACH compliant

The 272BX is a 95 VA high voltage (plate) and filament transformer with a 115 VAC, 60 Hz primary. It is the entry point to the 600V C.T. models, delivering 115 mA from its center-tapped high voltage secondary together with a 5V @ 2A winding and a 6.3V @ 3A filament winding.

Electrically, the 272BX is rated 95 VA with a 115 VAC, 60 Hz primary, a high voltage secondary rated 600V C.T. @ 115mA (RMS), and filament windings of 5V @ 2A (#1) and 6.3V @ 3A (#2). As with every 200 Series unit, it can be run full wave bridge or full wave C.T. Higher-current 600V C.T. options are the 272DX (144 mA), 272FX (172 mA), 272HX (230 mA) and 272JX (287 mA).

The case is an enclosed, 4 hole, chassis mount design in the vertical (X) mounting style, with minimum 6 in long leads. Listed dimensions are A 2.50 in (64 mm), B 3.25 in (83 mm), C 3.06 in (78 mm), D 2.00 in (51 mm), F 2.19 in (56 mm), with 0.20 in (5 mm) x 0.38 in (10 mm) mounting slots. Shipping weight is 3.5 lbs (1.59 kg).

For the primary, the 200 Series wiring notes describe two choices: use the white and gray wires and tape the black wire for 115 VAC input, or use the white and black wires and tape the gray wire where roughly 125V line voltage is producing too high a secondary voltage. Never connect power to both the gray and black wires at once. Insulation is Class A (105 degrees C), units are hi-pot tested at 2,000V RMS, the design is CSA certified (209651), and the part is RoHS and REACH compliant.

Ideal For

  • High voltage (plate) supply using a full wave bridge rectifier
  • Full wave center-tapped (C.T.) rectifier plate supply
  • 5V filament supply plus 6.3V filament supply
  • Chassis-mounted power supplies on 115 VAC, 60 Hz lines
  • Installations where roughly 125V line voltage raises the secondary

Mounting

LeadsMinimum 6" long leads
Mounting TypeVertical ("X")
Mounting StyleEnclosed, 4 hole, chassis mount

Overview

Series200 Series - High Voltage (Plate) & Filament - 32 VA to 454 VA
DescriptionTransformer, high voltage, 95VA, primary 115VAC, HV secondary 600V C.T. @ 115ma.
Part Number272BX
Product TypeHigh voltage (plate) and filament power transformer
Short DescriptionPOWER TX

Dimensions

Dimension A2.50 in (64 mm)
Dimension B3.25 in (83 mm)
Dimension C3.06 in (78 mm)
Dimension D2.00 in (51 mm)
Dimension F2.19 in (56 mm)
Mounting Slot (G)0.20 in (5 mm) x 0.38 in (10 mm)

Electrical

Filament #15V @ 2A
Filament #26.3V @ 3A
Power Rating95 VA
Wiring CautionNever connect power to both the Gray & Black wire - instantaneous destruction of the transformer will result
Primary Voltage115 VAC
Primary Frequency60 Hz
Primary Winding NoteProduction "running change" made to the primary winding, effective with August 2009 production
Rectifier ConfigurationFull wave bridge or full wave C.T.
Primary Wiring (115 VAC Input)White & Gray wires; tape the Black wire
AC High Voltage Secondary (RMS)600V C.T. @ 115ma.
Primary Wiring (Approx. 125 VAC Input)White & Black wires; tape the Gray wire

Identifiers

UPC623980276007
UNSPSC39121301

Packaging & Shipping

Shipping Weight3.5 lbs (1.59 kg)

Construction & Finish

EnclosureEnclosed
InsulationClass A insulation (105 degrees C)

Compliance & Certifications

Hi-Pot Test2,000V RMS
RoHS CompliantYes
REACH CompliantYes
CSA CertificationCSA certified (209651)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What voltages does the 272BX provide?▾

The 272BX provides a high voltage secondary rated 600V C.T. @ 115mA (RMS) plus filament windings of 5V @ 2A (#1) and 6.3V @ 3A (#2), from a 115 VAC, 60 Hz primary, with a 95 VA rating.

Can the 272BX be used with a full wave bridge rectifier?▾

Yes. 200 Series units can be run full wave bridge or full wave C.T. (center-tapped).

Can the 272BX run on a 125V line?▾

The series wiring notes describe a second choice for roughly 125V line voltage: use the white and black wires and tape the gray wire. For 115 VAC, use white and gray and tape black. Never connect power to both gray and black.

Will the 272BX work on 50 Hz power?▾

The 272BX primary is listed at 60 Hz only. The series notes point to the 300 Series for universal primaries and/or 50/60 Hz operation.

What certifications and insulation does the 272BX have?▾

The 200 Series design is CSA certified (209651), uses Class A insulation (105 degrees C) and is hi-pot tested at 2,000V RMS. The part is RoHS and REACH compliant.

How is the 272BX mounted and how much does it weigh?▾

It is an enclosed, 4 hole, chassis mount transformer in the vertical (X) mounting style, with dimension A 2.50 in (64 mm) and B 3.25 in (83 mm). Shipping weight is 3.5 lbs (1.59 kg).