266L16 open-style chassis-mount power transformer, 35.2 VA, with dual bobbin and colour-coded leads

Hammond 266L16 35.2VA Transformer, 16V C.T. or 8V at 4.4A

Hammond Manufacturing|

MPN: 266L16

|

UPC: 623980223995

In Stock
$28.92

Ships from and sold by A5 IT

Ground Shipping · $18.67Arrives by Monday, Oct 26
Order within 1h 5m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 35.2 VA rating: 16V @ 2.2A series (C.T.) or 8V @ 4.4A parallel
  • Dual primary for 117 VAC (parallel) or 234 VAC (series), 50/60 Hz
  • Dual secondaries: center-tapped, parallel connected or used individually
  • Class B (130 °C) insulation; UL listed as a Class A (105 °C) design
  • Dual bobbin design - no electrostatic shield required; hi-pot tested at 2,000V RMS
  • Open-style chassis mount, mounting style A, minimum 6" leads
  • UL listed (# E207860) Type 3AH, CSA certified (209651), RoHS and REACH compliant

The 266L16 is a 35.2 VA open-style power transformer rated 16 V center tapped at 2.2 A, or 8 V at 4.4 A in parallel, for chassis-mounted low-voltage supply circuits. It belongs to the Hammond 266 Series of low voltage/filament transformers and is aimed at OEM engineers, repair technicians and panel builders who mount the transformer directly to a chassis.

The primary is a dual 117/234 VAC, 50/60 Hz winding: connect the two primary halves in parallel for 117 V or in series for 234 V. The dual secondaries can be used as a center-tapped secondary (16V @ 2.2A), connected in parallel (8V @ 4.4A) or used individually, and the unit is designed for use with all windings engaged.

Construction is open style with a dual bobbin design, so no electrostatic shield is required. Hammond uses Class B (130 °C) insulation for extra protection, while the design is UL listed as Class A (105 °C). Every unit is hi-pot tested at 2,000V RMS, and all leads are a minimum of 6 in long. The transformer is UL listed (# E207860) Type 3AH, CSA certified (209651), and RoHS and REACH compliant.

The 266L16 uses mounting style A with 0.19 in (5 mm) mounting holes. Its listed dimensions are A 3.69 in (94 mm), B 2.20 in (56 mm), C 2.35 in (60 mm) and D 3.13 in (80 mm). It weighs 1.9 lbs and ships at 1.9 lbs (0.86 kg).

Ideal For

  • 8 V or 16 V centre-tapped low-voltage supply
  • Chassis-mount low voltage/filament power supply
  • Equipment built for either 117 VAC or 234 VAC, 50/60 Hz mains
  • Center-tapped, parallel or dual independent secondary outputs

Mounting

Mounting StyleA
Mounting Hole Width0.19 in (5 mm)

Overview

Series266 Series
Product TypePower transformer, low voltage/filament, dual primary & secondary
Long DescriptionPower transformer, chassis mount, 35.2VA, 16V @ 2.2A or 8V @ 4.4A, 266 Series
Short DescriptionPOWER TX 16V@2.2A, 8V @ 4.4A
Construction StyleOpen style, chassis mount

Dimensions

Dimension A3.69 in (94 mm)
Dimension B2.20 in (56 mm)
Dimension C2.35 in (60 mm)
Dimension D3.13 in (80 mm)

Electrical

Primary117/234 VAC, 50/60 Hz (dual primary)
Hi-Pot Test2,000V RMS
Winding UseDesigned for use with all windings engaged
Power Rating (VA)35.2
Secondary ConfigurationDual secondaries; usable as a center-tapped secondary, parallel connected or individually
Primary Wiring For 117 VParallel connection of primaries
Primary Wiring For 234 VSeries connection of primaries
Secondary VAC (RMS), Parallel8V @ 4.4A
Secondary VAC (RMS), Series (C.T.)16V @ 2.2A

Identifiers

UPC623980223995
UNSPSC39121301
Part Number266L16

Packaging & Shipping

Unit Weight1.9 lbs
Shipping Weight1.9 lbs (0.86 kg)

Construction & Finish

LeadsMinimum 6" (6.00 in) long leads
BobbinDual bobbin design - no electrostatic shield required
InsulationClass B (130 °C); UL listed as a Class A (105 °C) design

Compliance & Certifications

ULUL listed (# E207860) Type 3AH
CSACSA certified (209651)
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What is the 266L16 current rating?▾

It is rated 16V @ 2.2A with the secondaries in series (center-tapped) and 8V @ 4.4A in parallel, for 35.2 VA.

Can the 266L16 run on 234 V as well as 117 V?▾

Yes. The primary is rated 117/234 VAC, 50/60 Hz. Wire the two primary windings in parallel for 117 V or in series for 234 V.

What are the dimensions and weight of the 266L16?▾

Mounting style A; dimensions A 3.69 in (94 mm), B 2.20 in (56 mm), C 2.35 in (60 mm), D 3.13 in (80 mm). Unit weight is 1.9 lbs; shipping weight is 1.9 lbs (0.86 kg).

What certifications does the 266L16 carry?▾

The 266 Series is UL listed (# E207860) Type 3AH and CSA certified (209651). This part is listed as RoHS compliant and REACH compliant.

Does it need an electrostatic shield?▾

No. The dual bobbin design means no electrostatic shield is required.