(224) 955-1644
Hammond ManufacturingAuthorized partner store
Hammond 240MG1800 1800VA medical grade isolation transformer, 240 VAC to 240 VAC, white vented steel housing with 3 hospital grade Duplex 6-15R receptacles

Hammond 240MG1800 1800VA Medical Grade Isolation Transformer, 240V

Hammond Manufacturing|

MPN: 240MG1800

|

UPC: 623980513386

Available on Backorder
$690.53

Ships from and sold by A5 IT

Available on backorder — ships as soon as stock arrives

Ground Shipping · $132.99Ships as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 1800VA medical grade straight isolation, 240 VAC to 240 VAC, 50/60 Hz
  • Leakage current under 100 uA via Faraday shield; floating AC output reduces noise coupling
  • cULus listed to UL 60601-1 (1st Ed.) and CAN/CSA-C22.2 No. 601.1-M90 (R2005)
  • Hospital grade NEMA 6-15P input on 14/3 SJTW / 3 ft. cord
  • 3 hospital grade Duplex 6-15R receptacles
  • Input 7.81 A, output 7.50 A, 96% (min) full load efficiency
  • Switch / circuit breaker combo plus automatic thermal cut out
  • Vented 14 gauge steel housing, white powder paint, carrying handles

The Hammond 240MG1800 is a 1800VA medical grade plug-in line isolation transformer for straight isolation, 240 VAC to 240 VAC, rated 50/60 Hz. It is intended for non-patient connected indoor applications where sensitive electronics need protection, such as high end audio and studio use, medical electronics, and high end test equipment or laboratories. It is not intended to supply power to life support appliances.

Each unit provides complete line isolation and noise filtering and uses a Faraday shield to keep leakage current under 100 microamps, below UL60601-1 requirements. The floating AC output reduces noise coupling. The 240MG1800 is the 1800VA 240V model, drawing 7.81 A and delivering 7.50 A at 240 VAC with 96% minimum full load efficiency. It uses a shorter 3 ft cord and provides three duplex receptacles. Its wiring diagram shows a double-pole switch/circuit breaker, a 90°C TCO, 0.47µF and 10 µF 300V capacitors, and a shield tied to the chassis ground stud.

Construction is a vented 14 gauge steel housing in white powder paint, with carrying handles, venting louvers and an external grounding stud with wingnut. Input is a hospital grade 3-wire grounded NEMA 6-15P plug on a 14/3 SJTW / 3 ft. cord, and the output is 3 hospital grade Duplex 6-15R receptacles with North American pins. Protection comes from an on-off switch / circuit breaker combo plus a built in automatic thermal cut out.

The 240MG1800 is cULus listed to UL 60601-1 (1st Edition) and CAN/CSA-C22.2 No. 601.1-M90 (R2005), and is RoHS and REACH compliant. Every unit is 100% tested and inspected before packing. Input voltage tolerance is +/- 10%, and the shipping weight is 62 lbs (28.12 kg).

Ideal For

  • High end audio / studio use on 240V circuits
  • Medical electronics in non-patient connected indoor use
  • High end test equipment and laboratory power at 240V
  • Low-leakage isolated 240V supply for sensitive electronics

Overview

Series178, 240, 289, 298 "MG" Series; Straight Isolation (240 VAC to 240 VAC)
DescriptionIsolation transfortmer, medical grade, 1800VA, 240 VAC to 240 VAC, MG Series
RestrictionNot intended to be used to supply power to life support appliances
Intended UseNon-patient connected indoor applications where protection of sensitive electronics is required
Product TypeMedical grade plug-in line isolation transformer
Short DescriptionMEDICAL LINE ISOLATION, 1800VA

Dimensions

Drawing Dimensions (Front View)7.150 in (181.60 mm); 7.702 in (195.62 mm)
Drawing Dimensions (Top/side Views)12.399 in (314.94 mm); 13.528 in (343.61 mm); 8.815 in (223.90 mm); 8.717 in (221.41 mm)

Electrical

Frequency50/60 Hz
Capacitors0.47µF capacitor and 10 µF capacitor, 300V
Output TypeFloating AC output for reduced noise coupling
Power Rating1800 VA
ConfigurationStraight isolation (240 VAC to 240 VAC)
Input Current7.81 A
Input Voltage240 VAC
Output Current7.50 A
Output Voltage240 VAC
Leakage Current< 100 uA
Shield GroundingGRN, shield to chassis ground stud
Full Load Efficiency96% (min)
Isolation & FilteringComplete line isolation and noise filtering; Faraday shield reduces leakage currents below UL60601-1 requirements
Input Voltage Tolerance+/- 10%
Wiring Diagram - Primary240V, 7.81A via Switch/CB Pole 1 and Pole 2
Wiring Diagram - Secondary240V, 7.5A to hospital grade duplex

Protection

Switch / BreakerOn-Off Switch / Circuit Breaker combo (Switch / CB - Pole 1 and Pole 2)
Thermal ProtectionBuilt in automatic Thermal Cut Out
Thermal Cut Out Rating90°C TCO

Connections

Receptacle PinsNorth American (298G adaptor series offers international pinout adaptor plugs)
Output ReceptacleDuplex 6-15R (hospital grade)
External GroundingExternal grounding stud with wingnut; potential equalization conductor
Cord Style / Length14/3 SJTW / 3 ft.
Input Plug NEMA Type6-15P (hospital grade, 3-wire grounded) per series table and drawing; part page attribute lists 5-20P
Number Of Duplex Receptacles3
Input Plug (Drawing Call-out)3 ft medical grade NEMA 6-15P plug

Identifiers

UPC623980513386
UNSPSC39121301
Part Number240MG1800

Packaging & Shipping

Lifting NoteSeries user guide notes some units exceed 18 kg (40 lb); use safe lifting practices and both integral handles
Shipping Weight62 lbs (28.12 kg)

Construction & Finish

FinishWhite powder paint
HousingVented 14 gauge steel housing
HandlingIntegral carrying handles; rubber feet
VentilationVenting louvers; 4 mm perforated holes

Environmental & Protection

HumidityNot in excess of 95% RH (non-condensing)
LocationIndoor use, dry locations only
Hazardous AtmospheresNot for use with flammable gases or accelerants such as anesthetic mixtures, oxygen or nitrous oxide
Operating Temperature-15 to 55°C (5 to 131°F)
Storage & Transport Temperature-20 to 65°C

Compliance & Certifications

TestingEvery unit 100% tested and inspected before packing
RoHS CompliantYes
Safety ListingcULus Listed to UL 60601-1 (1st Edition) and CAN/CSA-C22.2 No. 601.1-M90 (R2005)
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

Can the 240MG1800 be used with patient-connected medical equipment?▾

No. The MG Series is intended for non-patient connected indoor applications that protect sensitive electronics, and it is not intended to supply power to life support appliances.

What is the leakage current of the 240MG1800?▾

Leakage current is under 100 uA. A Faraday shield reduces leakage currents below UL60601-1 requirements.

What plug and outlets does the 240MG1800 have?▾

It has a hospital grade NEMA 6-15P input plug on a 14/3 SJTW / 3 ft. cord and 3 hospital grade Duplex 6-15R receptacles. The user guide states units must be connected to comparable hospital grade plugs and receptacles to maintain grounding.

What are the input and output ratings?▾

Input is 240 VAC at 7.81 A; output is 240 VAC at 7.50 A; 1800VA at 50/60 Hz with 96% (min) full load efficiency.

What happens if it overloads or overheats?▾

If the breaker trips, unplug all loads, cycle the on/off switch to reset it and re-evaluate the total load. If the unit overheats, the built in thermal cut out removes power to the receptacles; unplug it and let it cool before restoring power.

What operating conditions does it need?▾

Indoor, dry locations only, operating between -15 and 55°C (5 to 131°F) and no more than 95% RH non-condensing, placed upright on its rubber feet with its ventilation unobstructed.