Hammond 227R 40VA 30V CT 400Hz Epoxy PCB Transformer
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Hammond Manufacturing 227R.
224-955-1644Key Features
- 40 VA at 400 Hz from a 115 VAC primary
- Series secondary: 30V C.T. @ 1.33A
- Parallel secondary: 15V @ 2.66A
- Epoxy cast to withstand shock and severe environments
- Two coil design: balanced windings, low magnetic radiation, no electrostatic shield
- PCB mount, 1.05 in max height, 0.05 in (1 mm) pin diameter
- 45 C temperature rise, 6% regulation
The 227R is a 40 VA, 400 Hz power transformer from the 227 Series, designed to mount on a printed circuit board and run from a 115 VAC primary. Its secondary is rated 30V C.T. @ 1.33A with the windings in series, or 15V @ 2.66A with them in parallel, giving designers two output options from one part.
The 227R is a 400 Hz, 40 VA model: 30 V centre-tapped at 1.33 A, or 15 V at 2.66 A in parallel.
The transformer is epoxy cast to withstand shock and severe environments. A two coil design provides balanced windings and low magnetic radiation, so no electrostatic shield is required.
Per the series table, the 227R stands 1.05 in high (max) with a pin diameter of 0.05 in (1 mm); shipping weight is 0.37 lbs (0.17 kg). Temperature rise is 45 C and regulation is 6%. The part is RoHS and REACH compliant, and it is classified under UNSPSC 39121301.
Note: the manufacturer states that the 226-227-228 product line will soon be discontinued as a stocked series and is available while quantities last.
Ideal For
- On-board 30V centre-tapped or 15V supply for 115 VAC equipment
- 400 Hz PCB-mounted power conversion
- Circuit boards exposed to shock or severe environments
- Replacement of an existing epoxy-cast PCB transformer
Overview
| Series | 227 Series (226-227-228 Series) |
| Description | Transformer, PCB mount, epoxy-cast, 40VA, 30V C.T. @ 1.33A / 15V @ 2.66A, 227 series |
| Product Type | Power transformer, PCB mount, epoxy cast |
| Availability Note | Series will soon be discontinued as a stocked series; available while quantities last |
| Short Description | POWER PCB 40VA 115V |
Dimensions
| High (Max) | 1.05 in |
| Pin Diameter | 0.05 in (1 mm) |
Electrical
| Frequency | 400 Hz |
| Regulation | 6% |
| Power Rating | 40 VA |
| Primary Voltage | 115 VAC |
| Temperature Rise | 45 C |
| Secondary (RMS) Series | 30V C.T. @ 1.33A |
| Secondary (RMS) Parallel | 15V @ 2.66A |
Identifiers
| UPC | 623980267852 |
| UNSPSC | 39121301 |
| Part Number | 227R |
Packaging & Shipping
| Shipping Weight | 0.37 lbs (0.17 kg) |
| Weight (Series Table) | 0.38 lbs |
Construction & Finish
| Mounting | PCB mount |
| Construction | Epoxy cast |
| Winding Design | Two coil design, balanced windings, low magnetic radiation; no electrostatic shield required |
Compliance & Certifications
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What outputs does the 227R provide?▾
With the secondaries in series it delivers 30V C.T. @ 1.33A; in parallel it delivers 15V @ 2.66A. The rating is 40 VA.
What primary voltage and frequency is the 227R for?▾
It uses a 115 VAC primary and is a 400 Hz model.
How is the 227R mounted?▾
It is a PCB mount transformer with a 0.05 in (1 mm) pin diameter and a maximum height of 1.05 in.
What are the temperature rise and regulation of the 227R?▾
Temperature rise is 45 C and regulation is 6%.
Is the 227R still available?▾
The manufacturer notes the 226-227-228 line will soon be discontinued as a stocked series and is available while quantities last.
Does it need an electrostatic shield?▾
No. The two coil design provides balanced windings and low magnetic radiation, so no electrostatic shield is required.
Related Products

227P — Transformer, PCB mount, epoxy-cast, 40VA, 26V C.T. @ 1.54A / 13V @ 3.08A, 227 series
Hammond Manufacturing · 227P

227T — Transformer, PCB mount, epoxy-cast, 40VA, 40V C.T. @ 1A / 20V @ 2A, 227 series
Hammond Manufacturing · 227T
Save 52%227N — Transformer, PCB mount, epoxy-cast, 40VA, 20V C.T. @ 2A / 10V @ 4A, 227 series
Hammond Manufacturing · 227N

228D — Transformer, PCB mount, epoxy-cast, 10VA, 20V C.T. @ 500ma / 10V @ 1A, 228 series
Hammond Manufacturing · 228D

227H — Transformer, PCB mount, epoxy-cast, 5VA, 40V C.T. @ 125ma / 20V @ 250ma, 227 series
Hammond Manufacturing · 227H