195T5 100 mH 5 A heavy current chassis mount choke with lug terminals

Hammond 195T5 100mH 5A Single-Coil Heavy Current Choke

Hammond Manufacturing|

MPN: 195T5

|

UPC: 623980263809

Available on Backorder
$112.41

Ships from and sold by A5 IT

Available on backorder — ships as soon as stock arrives

Ground Shipping · $26.11Ships as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 100 mH inductance at a rated 5 A D.C. current
  • 0.64 ohm listed resistance
  • Class A insulation
  • 750 VAC / 600 VDC max. operating voltage per drawing
  • Primary-to-core hipot 2000 V, 60 Hz, 1 sec
  • Lug terminals, 4-slot bracket mounting
  • Made in Canada, 14 lbs (6.35 kg)

The 195T5 is a heavy current chassis mount choke rated 100 mH at 5 A DC and listed in the single-coil 195 Series ordering table. It suits DC power supply filtering where high inductance is required at a 5 A load.

The part page lists 0.64 ohms resistance and Class A insulation. Its drawing specifies lug terminals, exciting current of 92.2 mA to 124.8 mA at 5.0 V, 60 Hz, operating voltage of 750 VAC max. and 600 VDC max., and a primary-to-core hipot of 2000 V, 60 Hz for 1 second. The label marks 100 mH @ 5.0ADC and Made in Canada.

Construction is the series open core and coil with 4-slot bracket mounting. Series table dimensions are A 4.50 in (114 mm), B 5.25 in (133 mm), C 3.75 in (95 mm), D 3.75 in (95 mm) and E 3.50 in (89 mm), with 0.20 x 0.38 in (5 x 10 mm) mounting slots; the drawing gives B as 5.25 in max. Weight is 14 lbs (6.35 kg). Note that the manufacturer part page description refers to parallel and series ratings and the 196 Series, while the series ordering table lists the 195T5 as a 195 Series part.

Across the 195-196 Series, inductance and resistance are held to a 15% tolerance, inductance is measured at rated D.C. current, and connections are made to a screw terminal or heavy copper tabs with holes. The series is rated for operation from -40C to 85C and storage from -40C to 105C, with a recommended maximum operating voltage of 600 VAC winding to core. The chokes are UL approved under Type 3AH, E207860, 30V7, and this part is listed as RoHS and REACH compliant.

Ideal For

  • 5 A DC power supply filtering
  • High-inductance DC filter choke
  • Chassis-mounted filter inductor

Overview

Series195 Series (Heavy Current Chassis Mount, 195-196 Series)
Product TypeChoke, heavy current chassis mount
Short DescriptionCHOKE
Coil ConfigurationSingle coil
Country Of ManufactureMade in Canada (per drawing label)
Manufacturer Part-Page Description (As Listed)Choke, heavy current, Parallel: 100mH @ 5A, Series: 0.5mH @ 50A, 196 Series

Dimensions

Dimension A4.50 in (114 mm)
Dimension B5.25 in (133 mm)
Dimension C3.75 in (95 mm)
Dimension D3.75 in (95 mm)
Dimension E3.50 in (89 mm)
Mounting Slot G0.20 in x 0.38 in (5 mm x 10 mm)
Dimension B (Drawing)5.25" max.

Electrical

Inductance100 mH
Resistance0.64 Ohms
Rated DC Current5 A
Exciting Current (Iex)92.2 mA - 124.8 mA @ 5.0 V, 60 Hz
Inductance MeasurementMeasured at rated D.C. current
Rated Current (Drawing)5.0 A DC
Operating Voltage (Drawing)750 VAC max. / 600 VDC max.
Inductance & Resistance Tolerance15%
Recommended Max. Operating Voltage600 VAC (winding to core)

Identifiers

UPC623980263809
UNSPSC39121301
Part Number195T5

Packaging & Shipping

Shipping Weight14 lbs (6.35 kg)
Weight (Drawing)14 lbs
Weight (Series Table)14 lbs

Construction & Finish

Mounting4-slot bracket mounting, chassis mount
ConstructionOpen core & coil
Label Marking100 mH @ 5.0ADC, date code
Insulation ClassA
Connections (Series)Screw terminal or heavy copper tabs with holes

Environmental & Protection

Storage Temperature-40C to 105C
Operating Temperature-40C to 85C

Compliance & Certifications

ULUL approved under Type 3AH, E207860, 30V7
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What is the 195T5 rated for?▾

100 mH at 5 A DC, per the part page attributes, series table and drawing label.

What hipot test does the 195T5 drawing specify?▾

Primary to core, 2000 V, 60 Hz for 1 second.

What voltage can the 195T5 operate at?▾

The drawing lists 750 VAC max. and 600 VDC max.

Is the 195T5 a single-coil or dual-coil choke?▾

The series ordering table lists it in the single-coil 195 Series; the part page description mentions parallel and series ratings and the 196 Series, so confirm against your application.

What is the operating temperature range of the 195T5?▾

The 195-196 Series is rated for operation from -40C to 85C and for storage from -40C to 105C.

Is the 195T5 UL approved?▾

Yes. All chokes in the 195-196 Series are UL approved under Type 3AH, E207860, 30V7.