
Hammond 195C100 1 mH 100 A DC Single Coil Chassis Mount Choke
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 1 mH inductance at 100 A DC rated current, measured at rated D.C. current
- 0.0036 ohm DC resistance; 15% tolerance on inductance and resistance
- Class B insulation per the 195 Series ordering table
- Single coil, open core and coil construction with 4-slot bracket mounting
- Screw terminal or heavy copper tab connections with holes
- Hipot tested at 2,500 VAC; 600 VAC recommended max (winding to core)
- UL approved under Type 3AH, E207860, 30V7; RoHS and REACH compliant
- Operating -40C to 85C; storage -40C to 105C
The 195C100 is a heavy current, chassis mount choke from the 195 Series, a single coil inductor rated 1 mH at 100 A DC. It is built for engineers and integrators designing high current power supply filters, where an open core and coil inductor bolted to a chassis or panel is the practical way to smooth DC output.
For 100 A DC circuits needing 1 mH, the 195C100 offers 0.0036 ohm resistance and Class B insulation, with a 6.50 in (165 mm) dimension B and a 26 lb table weight.
The ordering table lists dimension A at 5.25 in (133 mm), B at 6.50 in (165 mm), C at 4.47 in (114 mm), D at 4.38 in (111 mm) and E at 5.13 in (130 mm), with mounting slots (G) of 0.28 x 0.56 in (7 x 14 mm). Shipping weight is 28.98 lbs (13.15 kg), and the series table lists 26 lbs. Inductance is measured at the rated D.C. current, and both inductance and resistance carry a 15% tolerance.
Mounting uses a 4-slot bracket, and connections are made to a screw terminal or heavy copper tabs with holes. The 195 Series is hipot tested at 2,500 VAC with a recommended maximum operating voltage of 600 VAC (winding to core), and is rated for operation from -40C to 85C and storage from -40C to 105C. The chokes are UL approved under Type 3AH, E207860, 30V7, and the 195C100 is listed as RoHS and REACH compliant. Class b insulation is listed in the ordering table.
For AC applications from 60 Hz to 10,000 Hz, the manufacturer points to its 197 Series instead.
Ideal For
- High-current DC power supply filtering
- Heavy-current DC bus smoothing in chassis-mounted equipment
- Low-resistance series inductor for high-amperage DC circuits
Mounting
| Connections | Screw terminal or heavy copper tabs with holes |
| Mounting Style | 4-slot bracket, chassis mount |
| Mounting Slot (G) | 0.28 x 0.56 in (7 x 14 mm) |
Overview
| Series | 195 Series (Heavy Current Chassis Mount) |
| Description | Choke, heavy current chassis mount, single coil, 1mH @ 100A, 195 Series |
| Part Number | 195C100 |
| Construction | Open core & coil |
| Coil Configuration | Single coil |
Dimensions
| Dimension A | 5.25 in (133 mm) |
| Dimension B | 6.50 in (165 mm) |
| Dimension C | 4.47 in (114 mm) |
| Dimension D | 4.38 in (111 mm) |
| Dimension E | 5.13 in (130 mm) |
Electrical
| Tolerance | 15% on both inductance & resistance |
| Inductance | 1 mH |
| Resistance | 0.0036 Ohms |
| DC Current | 100 A |
| Insulation Class | B |
| Hipot Test (Series) | 2,500 VAC |
| Inductance Measurement | Measured at rated D.C. current |
| Recommended Max Operating Voltage (Series) | 600 VAC (winding to core) |
Identifiers
| UPC | 623980261201 |
| UNSPSC | 39121301 |
Packaging & Shipping
| Shipping Weight | 28.98 lbs (13.15 kg) |
| Weight (Series Table) | 26 lbs |
Environmental & Protection
| Storage Temperature | -40C to 105C |
| Operating Temperature | -40C to 85C |
Compliance & Certifications
| UL | UL approved under Type 3AH, E207860, 30V7 |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What are the inductance and current ratings of the 195C100?▾
The 195C100 is rated 1 mH at 100 A DC. Inductance is measured at the rated D.C. current, with a 15% tolerance.
What is the DC resistance of the 195C100?▾
The listed resistance is 0.0036 ohms, with a 15% tolerance.
How is the 195C100 mounted and wired?▾
It uses 4-slot bracket chassis mounting with 0.28 x 0.56 in (7 x 14 mm) mounting slots, and connections are made to a screw terminal or heavy copper tabs with holes.
What voltage and temperature ratings apply?▾
The 195 Series is hipot tested at 2,500 VAC with a recommended maximum operating voltage of 600 VAC (winding to core); operating range is -40C to 85C and storage -40C to 105C.
Is the 195C100 UL approved and RoHS compliant?▾
Yes. The series chokes are UL approved under Type 3AH, E207860, 30V7, and this part is listed as RoHS and REACH compliant.
How much does the 195C100 weigh?▾
Shipping weight is 28.98 lbs (13.15 kg); the series table lists 26 lbs.
Related Products
Save 52%195B150 — Choke, heavy current chassis mount, single coil, 0.5mH @ 150A, 195 Series
Hammond Manufacturing · 195B150
Save 52%195C20 — Choke, heavy current chassis mount, single coil, 1mH @ 20A, 195 Series
Hammond Manufacturing · 195C20
Save 52%195B100 — Choke, heavy current chassis mount, single coil, 0.5mH @ 100A, 195 Series
Hammond Manufacturing · 195B100
Save 52%195C30 — Choke, heavy current chassis mount, single coil, 1mH @ 30A, 195 Series
Hammond Manufacturing · 195C30
Save 52%195A300 — Choke, heavy current chassis mount, single coil, 0.3mH @ 200A, 195 Series
Hammond Manufacturing · 195A300
