Hammond 195A200 0.3mH 200A Heavy Current Chassis Mount Choke
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 0.3 mH inductance at 200 A DC, single coil design
- 0.0012 ohm resistance
- Drawing rating: 600 VDC max and 750 VAC max operating voltage
- Hipot tested 2500 V, 60 Hz, 1 sec primary to core
- Open core and coil, 4-slot bracket mount with 0.28 x 0.56 in slots
- UL approved under Type 3AH, E207860, 30V7 (series)
- Operating -40C to 85C; storage -40C to 105C
- 46 lbs unit weight; Made in Canada
The Hammond 195A200 is a heavy current, single coil chassis mount choke from the 195 Series, rated 0.3 mH at 200 A DC. It is built for high current power supply filtering and suits power electronics engineers and OEMs designing DC supplies that carry very high currents.
Construction is open core and coil with a 4-slot bracket mount. The part has a resistance of 0.0012 ohms. Its manufacturer drawing specifies an excitation current (Iex) of 5.41 to 7.32 A at 1 V, 60 Hz, an operating voltage of 750 VAC max and 600 VDC max, and a hipot test of 2500 V, 60 Hz for 1 second, primary to core. Series data gives a recommended maximum operating voltage of 600 VAC winding to core and states that all 195-196 chokes are UL approved under Type 3AH, E207860, 30V7.
Dimensions from the series table are A 7.50 in (191 mm), B 7.00 in (178 mm), C 6.50 in (165 mm), D 6.00 in (152 mm) and E 5.25 in (133 mm), with 0.28 x 0.56 in (7 x 14 mm) mounting slots; the drawing gives B as 7.00 in max. The choke weighs 46 lbs, with a shipping weight of 48 lbs (21.77 kg), and is marked Made in Canada. Connections are made to a screw terminal or heavy copper tabs with holes.
Inductance is measured at rated D.C. current, with a 15% tolerance on both inductance and resistance. It operates from -40C to 85C and can be stored from -40C to 105C. The 195A200 is RoHS and REACH compliant. For AC applications from 60 Hz to 10,000 Hz, the manufacturer points to its 197 Series.
Ideal For
- High current power supply filtering
- DC filtering at up to 200 A
- Chassis mount DC filter choke applications
Mounting
| Mounting Type | Open core & coil, 4-slot bracket mounting |
| Mounting Slot (G) | 0.28 in (7 mm) x 0.56 in (14 mm) |
Overview
| Series | 195 Series (single coil) |
| Product Type | Heavy Current Chassis Mount Choke |
| Long Description | Choke, heavy current chassis mount, single coil, 0.3mH @ 200A, 195 Series |
| Short Description | 0.3mH @ 200ADC |
| Coil Configuration | Single coil |
Dimensions
| Dimension A | 7.50 in (191 mm) |
| Dimension B | 7.00 in (178 mm); 7.00" max. per drawing |
| Dimension C | 6.50 in (165 mm) |
| Dimension D | 6.00 in (152 mm) |
| Dimension E | 5.25 in (133 mm) |
Electrical
| Hipot | 2500V, 60Hz, 1 sec (primary - core); series hipot tested at 2,500 VAC |
| Tolerance | 15% on both inductance and resistance |
| Inductance | 0.3 mH |
| Resistance | 0.0012 Ohms |
| DC Current | 200 A |
| Insulation Class | - |
| Inductance Measurement | Measured at rated D.C. current |
| Excitation Current (Iex) | 5.41 - 7.32 A @ 1V, 60Hz |
| Operating Voltage (Drawing) | 750 VAC max. |
| Operating Voltage DC (Drawing) | 600 VDC max. |
| Recommended Maximum Operating Voltage (Series) | 600 VAC (winding to core) |
Identifiers
| UPC | 623980208046 |
| UNSPSC | 39121301 |
| Part Number | 195A200 |
| Country Of Origin | Made in Canada (per drawing) |
Packaging & Shipping
| Weight | 46 lbs |
| Shipping Weight | 48 lbs (21.77 kg) |
Construction & Finish
| Connections | Screw terminal or heavy copper tabs with holes |
Environmental & Protection
| Storage Temperature Range | -40C to 105C |
| Operating Temperature Range | -40C to 85C |
Compliance & Certifications
| UL | UL approved under Type 3AH, E207860, 30V7 (series) |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What are the ratings of the 195A200?▾
0.3 mH at 200 A DC, with a resistance of 0.0012 ohms. Inductance is measured at rated D.C. current with a 15% tolerance on inductance and resistance.
What voltage can the 195A200 be used at?▾
The part drawing lists 600 VDC max and 750 VAC max operating voltage. The series data gives a recommended maximum operating voltage of 600 VAC winding to core.
How is the 195A200 mounted and connected?▾
It is an open core and coil choke with 4-slot bracket mounting using 0.28 x 0.56 in (7 x 14 mm) slots. Connections are made to a screw terminal or heavy copper tabs with holes.
Is the 195A200 UL approved?▾
The series data states that all 195-196 chokes are UL approved under Type 3AH, E207860, 30V7.
How heavy is the 195A200?▾
The unit weighs 46 lbs; the shipping weight is 48 lbs (21.77 kg).
Can I use the 195A200 in AC applications?▾
For AC applications from 60 Hz to 10,000 Hz, the manufacturer recommends its 197 Series instead.
Related Products
Save 52%195A300 — Choke, heavy current chassis mount, single coil, 0.3mH @ 200A, 195 Series
Hammond Manufacturing · 195A300
Save 52%195B100 — Choke, heavy current chassis mount, single coil, 0.5mH @ 100A, 195 Series
Hammond Manufacturing · 195B100
Save 52%195B150 — Choke, heavy current chassis mount, single coil, 0.5mH @ 150A, 195 Series
Hammond Manufacturing · 195B150
Save 52%195C100 — Choke, heavy current chassis mount, single coil, 1mH @ 100A, 195 Series
Hammond Manufacturing · 195C100
Save 52%195C20 — Choke, heavy current chassis mount, single coil, 1mH @ 20A, 195 Series
Hammond Manufacturing · 195C20