Hammond 193N 3H 500mA Enclosed DC Filter Choke, 600VDC
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 3 H inductance at 500 mA rated DC current
- 35 ohm resistance; 600 VDC maximum operating voltage
- Enclosed 4-hole chassis mount case, X11 mounting style with .203 x .38 in slots
- Vacuum impregnated with polyurethane varnish for quiet, long-life operation
- 15% tolerance on inductance and resistance; inductance measured at rated DC
- Minimum 8 in long leads
- Insulation class 105C; operating range -40C to 65C
- RoHS and REACH compliant
The Hammond 193N is a D.C. filter choke from the 193 Series of enclosed and potted chassis mount chokes, rated 3 henries at 500 mA DC. It is designed for high voltage power supply filtering, and is a natural fit for tube amplifier builders, audio equipment restorers and OEM engineers designing linear DC supplies.
The 193N is a 3 henry, 500 mA choke with 35 ohms resistance and a 600 VDC maximum operating voltage in the enclosed X11 case. The potted 193NP raises the voltage rating to 800 VDC.
The 193N is an enclosed, 4-hole chassis mount choke using the X11 mounting style: Dimension A 3.13 in, B 3.75 in, C 3.81 in, D 2.50 in and E 2.44 in, with .203 x .38 in mounting slots. The unit is vacuum impregnated with polyurethane varnish for quiet, long-life operation, has minimum 8 in long leads, and its case matches power transformers and tube audio output transformers.
Electrically, the 193N has a resistance of 35 ohms and a maximum operating voltage of 600 VDC. Inductance is measured at rated D.C. current, with a tolerance of 15% on both inductance and resistance; the unit will exhibit less inductance at slightly higher currents and more at lower currents. Insulation class is 105C and the operating temperature range is -40C to 65C. The part is RoHS and REACH compliant.
The series table lists a weight of 5 lbs, and the shipping weight is 5 lbs (2.27 kg).
Ideal For
- High voltage power supply filtering
- Tube audio equipment power supplies
- Tube audio equipment matching Hammond power and output transformer cases
- Chassis mount DC filter in linear power supplies
Mounting
| Mounting Type | Enclosed, 4-hole chassis mount |
| Mounting Slot (G) | .203 x .38 in |
| Mounting Style (Dimension Ref.) | X11 |
Overview
| Style | Enclosed |
| Series | 193 Series (Enclosed & Potted Chassis Mount) |
| Product Type | D.C. Filter Choke |
| Long Description | DC Filter Choke, Enclosed chassis mount, inductance 3H @ 500mA, 193 Series |
| Short Description | CHOKE 3H @ 500mA DC |
Dimensions
| Dimension A | 3.13 in |
| Dimension B | 3.75 in |
| Dimension C | 3.81 in |
| Dimension D | 2.50 in |
| Dimension E | 2.44 in |
Electrical
| Tolerance | 15% on both inductance and resistance |
| Inductance | 3H |
| Resistance | 35 Ohms |
| DC Current | 500 mA |
| Insulation Class | 105C |
| Inductance Measurement | Measured at rated D.C. current |
| Maximum Operating Voltage | 600 VDC |
Identifiers
| UPC | 623980259604 |
| UNSPSC | 39121301 |
| Part Number | 193N |
Packaging & Shipping
| Shipping Weight | 5 lbs (2.27 kg) |
| Weight (Series Table) | 5 lbs |
Construction & Finish
| Lead Length | Minimum 8 in |
| Impregnation | Vacuum impregnated with polyurethane varnish |
Environmental & Protection
| Operating Temperature Range | -40C to 65C |
Compliance & Certifications
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What are the inductance and current ratings of the 193N?▾
The 193N is rated 3H at 500 mA DC, with inductance measured at rated D.C. current and a 15% tolerance on inductance and resistance.
What is the maximum operating voltage of the 193N?▾
600 VDC maximum operating voltage.
How is the 193N mounted?▾
It is an enclosed, 4-hole chassis mount choke in the X11 mounting style with .203 x .38 in mounting slots.
Why does my measured inductance differ from the rating?▾
Inductance is specified at rated D.C. current; units exhibit less inductance at slightly higher currents or more at lower currents. The manufacturer notes that proper henry testing requires an LCR meter in junction with a 25A power supply that allows DC bias and a higher applied AC drive voltage.
What temperature and insulation ratings does the 193N have?▾
Insulation class is 105C and the operating temperature range is -40C to 65C.
Are open bracket-mount versions available?▾
For more sizes and voltages in an open, bracket mount type, the manufacturer points to its 153-159 Series.
Related Products
Save 52%193MP — DC Filter Choke, Potted chassis mount, inductance 10H @ 300mA, 193 Series
Hammond Manufacturing · 193MP
Save 52%193NP — DC Filter Choke, Potted chassis mount, inductance 3H @ 500mA, 193 Series
Hammond Manufacturing · 193NP
Save 52%193M — DC Filter Choke, Enclosed chassis mount, inductance 10H @ 300mA, 193 Series
Hammond Manufacturing · 193M
Save 52%193P — DC Filter Choke, Enclosed chassis mount, inductance 5H @ 500mA, 193 Series
Hammond Manufacturing · 193P
Save 52%193LP — DC Filter Choke, Potted chassis mount, inductance 5H @ 300mA, 193 Series
Hammond Manufacturing · 193LP