Hammond 187F10 10V CT 100VA Chassis Mount Power Transformer
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 10V C.T. secondary at 10 A, rated 100 VA
- Single 115 VAC primary, 50/60 Hz operation; dual-primary version is 186F10
- 4.03 in (102 mm) L x 2.25 in (57 mm) D x 2.56 in (65 mm) H, 3.50 in (89 mm) mounting centers
- Combination solder or quick connect terminals
- Split bobbin construction, no electrostatic shield needed
- Drawing test data: 2500 V, 60 Hz, 1 sec hi-pot, Iex 126 mA max
- UL listed (# E207860) Type 3AH and CSA Certified; RoHS and REACH compliant
The 187F10 is a 100 VA, F-size transformer delivering a 10 V center-tapped secondary at 10 A from a single 115 VAC primary, and has a published drawing with its test data. It belongs to the 187 series of chassis-mount, low-voltage power transformers, which run on 50/60 Hz and suit OEM engineers and panel builders who need a fixed step-down secondary with a center tap. If you need a dual 115/230 VAC primary with the same secondary, the ordering table pairs this part with the 186F10.
Construction is an economical open-style channel frame for chassis mounting. Split bobbin construction removes the need for an electrostatic shield, insulation is Class B (130 °C), and temperature rise is designed not to exceed Class A for longer life. Combination solder or quick connect terminals allow either soldered leads or quick connect wiring.
In the F-size frame, the 187F10 measures 4.03 in (102 mm) long, 2.25 in (57 mm) deep not including terminals (2.62 in (67 mm) to the terminal), and 2.56 in (65 mm) high, with 3.50 in (89 mm) mounting centers. Shipping weight is 2.7 lbs (1.22 kg).
The 187F10 drawing lists acceptance data measured at 115 V, 60 Hz on terminals 2 and 4: excitation current of 126 mA max, a no-load secondary of 11.17 V ±2% across terminals 6 to 10 (5.583 V ±2% per half, with terminal 8 as the center tap), primary DC resistance of 4.209 ±20% and secondary DC resistance of 0.040 ±20% at 20°C. Primary-to-secondary hi-pot is 2500 V, 60 Hz, 1 sec, and the terminals are brass.
The series is hi-pot tested to 2 KV RMS, UL listed (# E207860) Type 3AH and CSA Certified. This part is listed as RoHS and REACH compliant.
Ideal For
- Chassis-mounted 10V center-tapped supplies from a 115 VAC line
- OEM equipment power sections needing a 50/60 Hz step-down transformer
- Builds wired with solder or quick connect terminals
- Designs rated around 100 VA
Overview
| Series | 187 Series (single primary); 186-187 Series family |
| Product Type | Power transformer, chassis mount |
| Long Description | Transformer, chassis mount, 115VAC, 100VA, 10V C.T.@10A, 187 Series |
| Short Description | TX 115VAC, 100VA 50/60HZ |
| Construction Style | Open style, channel frame - chassis mount |
| Dual-Primary (115/230 VAC Equivalent | 186F10 |
Dimensions
| Height (C) | 2.56 in (65 mm) |
| Length (L) | 4.03 in (102 mm) |
| Drawing Dimension A | 4.031" ±0.063 |
| Drawing Dimension B | 2.220" ±0.125 |
| Drawing Dimension C | 2.620" ±0.063 |
| Drawing Dimension D | 3.563" ±0.063 |
| Drawing Dimension E | 2.580" ±0.063 |
| Drawing Dimension G | 0.187" ±0.015 |
| Mounting Centers (D) | 3.50 in (89 mm) |
| Depth To Terminal (E) | 2.62 in (67 mm) |
| Depth, Not Including Terminals (B) | 2.25 in (57 mm) |
Electrical
| Frequency | 50/60 Hz |
| Power Rating | 100 VA |
| Primary Voltage | 115 VAC (single primary) |
| Secondary Current | 10 A |
| Terminal Assignment | Primary 115 V: Term 2 - Term 4; Secondary: Term 6 - Term 10, center tap Term 8 |
| Hi-Pot Test (Series) | 2 KV RMS |
| DC Resistance, Primary | 4.209 ±20% @ 20°C (Term 2 - Term 4) |
| Secondary Voltage (RMS) | 10V C.T. |
| DC Resistance, Secondary | 0.040 ±20% @ 20°C (Term 6 - Term 10) |
| Excitation Current (Iex) | 126 mA max @ 115 V, 60 Hz, Term 2 - Term 4 |
| Hi-Pot Test (Part Drawing) | 2500 V, 60 Hz, 1 sec (primary - secondary) |
| Secondary No-Load Voltage (Each Half) | Term 6 - Term 8 = Term 8 - Term 10 = 5.583 V ±2% |
| Secondary No-Load Voltage (Full Winding) | Term 6 - Term 10 = 11.17 V ±2% @ 115 V, 60 Hz primary |
Identifiers
| UPC | 623980761381 |
| UNSPSC | 39121301 |
| Part Number | 187F10 |
Packaging & Shipping
| Shipping Weight | 2.7 lbs (1.22 kg) |
Construction & Finish
| Bobbin | Split bobbin construction (eliminates the need for an electrostatic shield) |
| Terminals | Combination solder or quick connect |
| Label Marking | 115V primary, 10VCT secondary, 10A, 50/60Hz, 100VA |
| Drawing Revision | Rev. 0, released 01/22/25 |
| Insulation Class | Class B (130 °C) |
| Temperature Rise | Designed not to exceed Class A |
| Terminal Material | Brass |
Compliance & Certifications
| UL | UL listed (# E207860) Type 3AH |
| CSA | CSA Certified |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What are the output ratings of the 187F10?▾
The 187F10 has a 10V C.T. (center-tapped) RMS secondary rated 10 A, for 100 VA, from a 115 VAC primary at 50/60 Hz.
Is there a 230 VAC version of the 187F10?▾
Yes. The ordering table lists 186F10 as the dual-primary 115/230 VAC part with the same 10V C.T. secondary and 10 A rating. The 187F10 is the single-primary 115 VAC version.
What are the mounting dimensions of the 187F10?▾
It measures 4.03 in (102 mm) long, 2.25 in (57 mm) deep not including terminals, 2.62 in (67 mm) deep to the terminals and 2.56 in (65 mm) high, with mounting centers of 3.50 in (89 mm). The part drawing gives dimension D as 3.563" ±0.063.
How are connections made?▾
The transformer has combination solder or quick connect terminals, so leads can be soldered or fitted with quick connect terminals.
What approvals does the 187F10 carry?▾
The 186-187 series is UL listed (# E207860) Type 3AH and CSA Certified, and this part is listed as RoHS and REACH compliant.
What test data does the 187F10 drawing specify?▾
At 115 V, 60 Hz the excitation current is 126 mA max; no-load secondary is 11.17 V ±2% across terminals 6-10 and 5.583 V ±2% per half; primary-secondary hi-pot is 2500 V, 60 Hz, 1 sec.
Related Products
Save 52%187E56 — Transformer, chassis mount, 115VAC, 56VA, 56V C.T.@1A, 187 Series
Hammond Manufacturing · 187E56
Save 52%187F12 — Transformer, chassis mount, 115VAC, 100.8VA, 12.6V C.T.@8A, 187 Series
Hammond Manufacturing · 187F12
Save 52%187E48 — Transformer, chassis mount, 115VAC, 57.9VA, 48V C.T.@1.2A, 187 Series
Hammond Manufacturing · 187E48
Save 52%187F120 — Transformer, chassis mount, 115VAC, 102VA, 120V C.T.@0.85A, 187 Series
Hammond Manufacturing · 187F120
Save 52%187E36 — Transformer, chassis mount, 115VAC, 54VA, 36V C.T.@1.5A, 187 Series
Hammond Manufacturing · 187E36