187B120 6 VA open-frame chassis mount power transformer, 115 VAC single primary, 120V C.T. secondary

Hammond 187B120 6VA 120V C.T. 115VAC Chassis Mount Transformer

Hammond Manufacturing|

MPN: 187B120

|

UPC: 623980953304

In Stock
$6.07

Ships from and sold by A5 IT

Ground Shipping · $16.89Arrives by Monday, Oct 26
Order within 59m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 120V C.T. RMS center-tapped secondary rated 0.05 A
  • 6 VA power rating
  • Single 115 VAC primary, 50/60 Hz
  • Combination solder or quick connect terminals
  • Split bobbin construction eliminates the need for an electrostatic shield
  • Hi-pot tested to 2 KV RMS; Class B (130 C) insulation, temperature rise not to exceed Class A
  • UL listed (# E207860) Type 3AH and CSA certified; RoHS and REACH compliant
  • Open channel frame chassis mount, 2.37 in (60 mm) long with 2.00 in (51 mm) mounting centers

The 187B120 is a 6 VA open-style, chassis mount power transformer from the 187 Series with a single 115 VAC primary for 50/60 Hz supplies. The center-tapped secondary delivers 120V C.T. RMS at 0.05 A. It uses the B-size frame of the 186-187 range, a step up from the A frame in both rating and footprint. It is aimed at OEM engineers, technicians and equipment builders who need a small low voltage AC source mounted directly to a chassis.

Construction follows the 186-187 Series design: an economical open style, channel frame for chassis mounting, and split bobbin construction that eliminates the need for an electrostatic shield. Insulation material is Class B (130 C), and the design keeps temperature rise from exceeding Class A for longer life. Each unit is hi-pot tested to 2 KV RMS.

Overall length is 2.37 in (60 mm), height is 1.37 in (35 mm) and depth is 1.25 in (32 mm) not including terminals, or 1.62 in (41 mm) measured to the terminals. Mounting centers are 2.00 in (51 mm). Shipping weight is 0.5 lbs (0.23 kg).

Wiring is by combination solder or quick connect terminals. The dual 115/230 VAC primary version with the same secondary rating is 186B120. The series is UL listed (# E207860) Type 3AH and CSA certified, and this part is listed as RoHS and REACH compliant.

Ideal For

  • Low voltage AC supply inside chassis-mounted equipment
  • 120V center-tapped secondary power for control and electronic circuits
  • Equipment powered from 115 VAC, 50/60 Hz mains
  • Panel and OEM builds using solder or quick connect wiring

Overview

Series187 Series (186-187 Series)
DescriptionTransformer, chassis mount, 115VAC, 6VA, 120V C.T.@0.05A, 187 Series
Part Number187B120
Product TypePower transformer, low voltage, chassis mount, open style
Short DescriptionTX 115VAC, 6VA 50/60HZ

Dimensions

Height (C)1.37 in (35 mm)
Length (L)2.37 in (60 mm)
Mounting Centers (D)2.00 in (51 mm)
Depth To Terminal (E)1.62 in (41 mm)
Depth, Not Including Terminals (B)1.25 in (32 mm)

Electrical

Frequency50/60 Hz
Hi-Pot Test2 KV RMS
Power Rating6 VA
Primary Voltage115 VAC
Secondary Current0.05 A
Primary ConfigurationSingle Primary 115 VAC
Secondary Voltage (RMS)120V C.T.

Identifiers

UPC623980953304
UNSPSC39121301
Dual Primary (115/230 VAC Equivalent186B120

Packaging & Shipping

Shipping Weight0.5 lbs (0.23 kg)

Construction & Finish

BobbinSplit bobbin (eliminates need for electrostatic shield)
MountingChassis mount, open style channel frame
TerminalsCombination solder or quick connect
Insulation ClassClass B or 130 C
Temperature RiseDesigned not to exceed Class A

Compliance & Certifications

ULUL listed (# E207860) Type 3AH
CSACSA Certified
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What input voltage does the 187B120 accept?▾

It has a single 115 VAC primary and operates on 50/60 Hz.

What is the secondary output of the 187B120?▾

The secondary is 120V C.T. RMS (center tapped) rated at 0.05 A, for a 6 VA power rating.

Is there a 115/230 VAC version of the 187B120?▾

Yes, the dual primary equivalent with the same secondary rating is 186B120.

How is it mounted and wired?▾

It is an open style, channel frame chassis mount transformer with 2.00 in (51 mm) mounting centers, and it uses combination solder or quick connect terminals.

Does it need an electrostatic shield?▾

No. The series uses split bobbin construction, which eliminates the need for an electrostatic shield.

What safety approvals does it carry?▾

The 186-187 Series is UL listed (# E207860) Type 3AH and CSA certified, and is hi-pot tested to 2 KV RMS. This part is listed as RoHS and REACH compliant.