(224) 955-1644
Hammond ManufacturingAuthorized partner store
Hammond 186C28 open style channel frame chassis mount transformer, 115/230 VAC dual primary, 28V C.T. 0.42 A secondary

Hammond 186C28 28V C.T. 0.42A, 12VA Dual-Primary Transformer

Hammond Manufacturing|

MPN: 186C28

|

UPC: 623980761978

In Stock
$8.69

Ships from and sold by A5 IT

Ground Shipping · $16.89Arrives by Monday, Oct 26
Order within 2h 46m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • Dual primary: 115 VAC or 230 VAC input, 50/60 Hz operation
  • 28V C.T. RMS secondary rated 0.42 A for 12 VA
  • Combination solder or quick connect terminals
  • Split bobbin construction eliminates the need for an electrostatic shield
  • Hi-pot tested to 2 KV RMS; Class B (130 C) insulation, temperature rise designed not to exceed Class A
  • Open style channel frame for chassis mounting on 2.37 in (60 mm) mounting centers
  • UL listed (# E207860) Type 3AH, CSA certified, RoHS and REACH compliant

The Hammond 186C28 is a low voltage, chassis mount power transformer from the 186 Series with a dual 115/230 VAC primary. It delivers a 28V C.T. (center-tapped) RMS secondary rated at 0.42 A, for a 12 VA rating, and operates on either 50 Hz or 60 Hz supplies. That makes it a practical choice for OEM engineers, panel builders and service technicians who need one transformer that can be wired for 115 VAC or 230 VAC mains.

Built on the C-size frame, the middle of the dual-primary range, the 186C28 uses an economical open style, channel frame design made for chassis mounting. Its split bobbin construction eliminates the need for an electrostatic shield. Insulation is Class B (130 C), and the transformer is designed for a lower temperature rise that does not exceed Class A, for longer life. Each unit is hi-pot tested to 2 KV RMS.

Dimensions from the series table: length (L) 2.81 in (71 mm), depth not including terminals (B) 1.37 in (35 mm), height (C) 1.62 in (41 mm), mounting centers (D) 2.37 in (60 mm) and depth to terminal (E) 1.73 in (44 mm). The shipping weight is 0.68 lbs (0.31 kg). Terminals are a combination solder or quick connect type, so the leads can be soldered or connected with quick connect fittings.

The 186C28 is UL listed (# E207860) Type 3AH and CSA certified, and the part page lists it as RoHS compliant and REACH compliant. If your design only needs a single 115 VAC primary, the equivalent single-primary part in the 187 Series is the 187C28.

Ideal For

  • Chassis-mounted low voltage power supplies needing 28V C.T. at up to 0.42 A
  • Equipment that must be wired for either 115 VAC or 230 VAC mains
  • Designs operating on 50 Hz or 60 Hz supplies
  • Builds using solder or quick connect terminal wiring

Overview

Series186 Series (Dual Primary 115/230 VAC)
Part Number186C28
Product TypeTransformer, chassis mount, low voltage
Long DescriptionTransformer, chassis mount, 115/230VAC, 12VA, 28V C.T.@0.42A, 186 Series
Short DescriptionTX 115/230, 12VA 50/60HZ
Single Primary (115 VAC Equivalent187C28 (187 Series)

Dimensions

Height (C)1.62 in (41 mm)
Length (L)2.81 in (71 mm)
Mounting Centers (D)2.37 in (60 mm)
Depth To Terminal (E)1.73 in (44 mm)
Depth, Not Including Terminals (B)1.37 in (35 mm)

Electrical

Frequency50/60 Hz
Hi-Pot Test2 KV RMS
Power Rating12 VA
Primary Voltage115 / 230 VAC
Secondary Current0.42 A
Secondary (RMS) VAC28V C.T.
Primary ConfigurationDual Primary 115/230 VAC

Identifiers

UPC623980761978
UNSPSC39121301

Packaging & Shipping

Shipping Weight0.68 lbs (0.31 kg)

Construction & Finish

BobbinSplit bobbin (eliminates the need for an electrostatic shield)
MountingChassis mount
TerminalsCombination solder or quick connect
Frame StyleOpen style, channel frame
Temperature RiseDesigned not to exceed Class A
Insulation MaterialClass B or 130 C

Compliance & Certifications

ULUL listed (# E207860) Type 3AH
CSACSA Certified
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

Can the 186C28 run on both 115 VAC and 230 VAC?▾

Yes. The 186C28 is a 186 Series dual primary transformer with a 115/230 VAC primary, and it operates on 50/60 Hz.

What is the secondary output of the 186C28?▾

The secondary is 28V C.T. RMS (center-tapped) rated at 0.42 A, for a 12 VA rating.

What are the mounting dimensions of the 186C28?▾

The series table lists length (L) 2.81 in (71 mm), depth not including terminals (B) 1.37 in (35 mm), height (C) 1.62 in (41 mm), mounting centers (D) 2.37 in (60 mm) and depth to terminal (E) 1.73 in (44 mm).

How are connections made to this transformer?▾

The 186-187 Series uses combination solder or quick connect terminals, so wiring can be soldered or connected with quick connect terminals.

Is the 186C28 UL listed and CSA certified?▾

Yes. The series is UL listed (# E207860) Type 3AH and CSA certified, and the 186C28 part page lists it as RoHS compliant and REACH compliant.

Is there a single-primary version of the 186C28?▾

Yes. The 187 Series single primary 115 VAC equivalent listed in the same ordering table row is the 187C28.