186B10 6 VA open style chassis mount transformer with 115/230 VAC primary and 10V C.T. secondary

Hammond 186B10 6 VA 10V C.T. Dual-Primary Chassis Mount Transformer

Hammond Manufacturing|

MPN: 186B10

|

UPC: 623980761824

In Stock
$7.69

Ships from and sold by A5 IT

Ground Shipping · $16.89Arrives by Monday, Oct 26
Order within 3h 42m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 6 VA rating with 10V C.T. secondary at 0.6 A
  • Dual primary 115/230 VAC, 50/60 Hz operation
  • Combination solder or quick connect terminals
  • Split bobbin construction eliminates the need for an electrostatic shield
  • Class B (130 C) insulation; temperature rise designed not to exceed Class A
  • Hi-pot tested to 2 KV RMS
  • Open style channel frame chassis mount, 2.37 in L x 1.25 in D x 1.37 in H
  • UL listed (# E207860) Type 3AH and CSA certified; RoHS and REACH compliant

The 186B10 is a 6 VA low voltage power transformer from the 186 Series, the dual primary (115/230 VAC) half of the 186-187 family. It provides a 10V C.T. secondary rated at 0.6 A and operates on 50/60 Hz, suiting OEM engineers, electricians and equipment builders who need a small chassis-mounted low voltage supply that can run from either 115 V or 230 V.

It uses an economical open style, channel frame chassis mount design with combination solder or quick connect terminals. Split bobbin construction eliminates the need for an electrostatic shield, insulation material is Class B (130 C), and the design keeps temperature rise from exceeding Class A for longer life. Each unit is hi-pot tested to 2 KV RMS.

Dimensions from the series table: length (L) 2.37 in (60 mm), depth not including terminals (B) 1.25 in (32 mm), height (C) 1.37 in (35 mm), mounting centers (D) 2.00 in (51 mm) and depth to terminal (E) 1.62 in (41 mm). The shipping weight is 0.43 lbs (0.20 kg).

If only a 115 VAC single primary is needed, the series table lists 187B10 as the matching 187 Series part with the same 10V C.T. secondary and 0.6 A rating. The 186-187 Series is UL listed (# E207860) Type 3AH and CSA certified, and the 186B10 is RoHS and REACH compliant.

Ideal For

  • Low voltage supplies in equipment running on 115 V or 230 V
  • 10V C.T. centre-tapped secondary circuits up to 0.6 A
  • Chassis-mounted power transformer in OEM equipment
  • Wiring with solder or quick connect terminations

Overview

Series186-187 Series - Low Voltage Solder or Quick Connect Terminals, 2.4 VA to 102 VA
DescriptionTransformer, chassis mount, 115/230VAC, 6VA, 10V C.T.@0.6A, 186 Series
Part Number186B10
Short DescriptionTX 115/230, 6VA 50/60HZ
Single Primary (115 VAC Equivalent187B10

Dimensions

Height (C)1.37 in (35 mm)
Length (L)2.37 in (60 mm)
Mounting Centers (D)2.00 in (51 mm)
Depth To Terminal (E)1.62 in (41 mm)
Depth, Not Including Terminals (B)1.25 in (32 mm)

Electrical

Frequency50/60 Hz
Hi-pot Test2 KV RMS
Power Rating6 VA
Primary TypeDual primary
Primary Voltage115 / 230 VAC
Secondary (RMS)10V C.T.
Secondary Current0.6 A

Identifiers

UPC623980761824
UNSPSC39121301

Packaging & Shipping

Shipping Weight0.43 lbs (0.20 kg)

Construction & Finish

FrameOpen style, channel frame
BobbinSplit bobbin (no electrostatic shield required)
MountingChassis mount
TerminalsCombination solder or quick connect
Insulation ClassClass B (130 C)
Temperature RiseDesigned not to exceed Class A

Compliance & Certifications

ULUL listed (# E207860) Type 3AH
CSACSA Certified
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What is the output of the 186B10?▾

It has a 10V C.T. secondary rated at 0.6 A, for a power rating of 6 VA.

Can it run on both 115 V and 230 V?▾

Yes. The 186B10 is a 186 Series dual primary transformer rated 115/230 VAC and operates on 50/60 Hz.

Is there a 115 VAC-only version of the 186B10?▾

The series table lists 187B10 as the single primary (115 VAC) 187 Series part with the same 10V C.T. secondary and 0.6 A rating.

What are its dimensions?▾

Length 2.37 in (60 mm), depth not including terminals 1.25 in (32 mm), height 1.37 in (35 mm), mounting centers 2.00 in (51 mm) and depth to terminal 1.62 in (41 mm).

What terminals and construction does it use?▾

Combination solder or quick connect terminals on an open style, channel frame chassis mount design, with split bobbin construction that eliminates the need for an electrostatic shield.

What certifications and ratings apply?▾

The series is UL listed (# E207860) Type 3AH and CSA certified, hi-pot tested to 2 KV RMS, with Class B (130 C) insulation. This part is RoHS and REACH compliant.