183K36 56VA low voltage PCB mount power transformer with 36V center-tapped secondary

Hammond 183K36 56VA 36V Center-Tapped Dual Primary PCB Transformer

Hammond Manufacturing|

MPN: 183K36

|

UPC: 623980259062

In Stock
$14.76

Ships from and sold by A5 IT

Ground Shipping · $18.67Arrives by Monday, Oct 26
Order within 1h 5m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 56VA rating: 36V C.T. @ 1.56A with secondaries in series
  • 18V @ 3.12A with secondaries connected in parallel
  • Dual primary for 115 or 230 VAC, 50/60 Hz operation
  • Dual non-concentric secondaries: series, parallel or used separately
  • Class F (155 degrees C) insulation and 4,000V RMS hipot
  • PCB mount, industry standard pin spacing, four hole #6 screw mounting (screws not provided)
  • cUL listed; drawing shows cURus, CE and TUV; RoHS and REACH compliant

The 183K36 is a 56VA low voltage power transformer for printed circuit board mounting, part of the 183 Series of universal PCB transformers. It is aimed at OEM engineers and electronics designers who need an isolated low-voltage AC supply on a board that must run from either 115 or 230 VAC mains at 50/60 Hz.

The 183K36 is the highest-voltage K-size model in the 183 Series: 36V C.T. at 1.56A in series, or 18V at 3.12A in parallel, at 56VA. The dual winding secondaries are non-concentrically wound and can be wired in series, in parallel or used separately; when they are connected in series (pin 9 to pin 10) that junction acts as the center tap.

Construction is a low profile split bobbin with a top shroud, Class F insulation rated 155 degrees C and a 4,000V RMS hipot. Low primary-to-secondary coupling means no electrostatic shield is required. The body measures 3 x 2.5 x 1.81 in (76.2 x 63.5 x 46 mm), with a unit weight of 1.7 lbs (0.77 kg); the shipping weight is 1.61 lbs (0.73 kg).

The transformer uses P.C. board pins on industry standard spacing, with 0.045 in square pins and four hole mounting for #6 screws (mounting screws not provided). Pin numbers are not marked on the unit - the paint dot always identifies the secondary side (pins 12-7). It is cUL listed, with cURus, CE and TUV agency listings shown on its drawing, and RoHS and REACH compliant.

Ideal For

  • Low-voltage AC supply on printed circuit boards
  • 36V center-tapped or 18V secondary supply for board-level electronics
  • Equipment that must operate on 115 or 230 VAC, 50/60 Hz mains
  • OEM power supply sections needing low primary-to-secondary coupling

Mounting

Mounting TypeP.C. board mount with industry standard pin spacing
Mounting HolesFour hole mounting (56VA size); mounting screws not provided
Mounting Screw#6
Pin Size (Square)0.045 in (1.1 mm)
Pin IdentificationPin numbers are not on the unit; the paint dot is always on the secondary side (pins 12-7)

Overview

Series183 Series (Low Voltage PCB Mount - Universal - 2.5 VA to 56 VA)
DescriptionTransformer, low voltage PCB mount, 115/230V, 56VA, 36V C.T. @ 1.56A, 183 Series
Product TypeLow voltage PCB mount power transformer
Short DescriptionPOWER PCB 56VA 115/230
Bulk Pack Part No.183K36-BULK

Dimensions

Width (W)2.5 in (63.5 mm)
Height (H)1.81 in (46 mm)
Length (L)3 in (76.2 mm)
Dimension A0.6 in (15.2 mm)
Dimension B0.3 in (7.6 mm)
Dimension C1.9 in (48.3 mm)
Dimension N2 in (50.8 mm)
Dimension P2.5 in (63.5 mm)
Unit Weight1.7 lbs / 0.77 kg

Electrical

Hipot4,000V RMS
PrimaryDual primary, 115 or 230 VAC, 50/60 Hz
Center TapSecondaries connected in series (pin 9 connected to pin 10) - that connection acts as the C.T. (center tap)
Power Rating56 VA
Primary Pins1, 3, 4, 6 (115V: parallel connection; 230V: series connection)
Secondary Pins7, 9, 10, 12 (parallel or series connection)
Secondary WindingsDual winding secondaries, non-concentrically wound; can be wired in series, parallel or used separately
Secondary (RMS), Series36V C.T. @ 1.56A
Secondary (RMS), Parallel18V @ 3.12A
Primary To Secondary CouplingLow - no electrostatic shield required

Identifiers

UPC623980259062
UNSPSC39121301
Part Number183K36

Packaging & Shipping

Shipping Weight1.61 lbs (0.73 kg)

Construction & Finish

ConstructionLow profile, split bobbin with top shroud design
Insulation ClassClass F, 155 degrees C

Compliance & Certifications

ListingscUL
RoHS CompliantYes
REACH CompliantYes
Agency Listings (Part Drawing)cURus, CE, and TUV

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What output does the 183K36 provide?▾

It is rated 56VA: 36V C.T. @ 1.56A with the two secondaries in series, or 18V @ 3.12A with them in parallel. The secondaries can also be used separately.

Can it run on both 115V and 230V mains?▾

Yes. It has a dual primary for 115 or 230 VAC, 50/60 Hz operation. The drawing shows the primaries in parallel for 115V and in series for 230V.

Where is the center tap?▾

When the secondaries are connected in series (pin 9 connected to pin 10), that connection acts as the C.T. (center tap).

How is it mounted?▾

It is a P.C. board mount transformer with industry standard pin spacing and 0.045 in square pins, plus four hole mounting for #6 screws. Mounting screws are not provided.

What are the dimensions and weight of the 183K36?▾

3 x 2.5 x 1.81 in (76.2 x 63.5 x 46 mm), with a unit weight of 1.7 lbs (0.77 kg). Shipping weight is 1.61 lbs (0.73 kg).