Key Features

  • 10 VA rating: 12.6V C.T. @ 0.8A with secondaries in series, 6.3V @ 1.6A in parallel
  • Universal dual primary: 115 VAC (parallel) or 230 VAC (series), 50/60 Hz
  • Dual non-concentrically wound secondaries usable in series, parallel or separately
  • Hipot 4,000 V RMS; Class F (155 °C) insulation; no electrostatic shield required
  • Low profile split bobbin body, 1.88 x 1.56 x 1.38 in, 0.036 in square pins
  • P.C. board mount, industry standard pin spacing, two-hole #4 screw mounting (screws not provided)
  • cUL listed series; RoHS and REACH compliant

The 183G12 is a 10 VA low voltage transformer for printed circuit board mounting. Its two secondary windings give 12.6 V C.T. at 0.8 A in series or 6.3 V at 1.6 A in parallel, and its dual primary accepts 115 VAC or 230 VAC at 50/60 Hz. It doubles the VA of the 5 VA 12.6 V model in the same series while keeping the low-profile, board-mounted format.

The low profile split bobbin and top shroud design separates primary and secondary windings; because the dual secondaries are non-concentrically wound, coupling is low and no electrostatic shield is needed. Hipot is 4,000 V RMS and the insulation system is Class F at 155 °C.

The series mounting table gives the 10 VA size as 1.88 in long, 1.56 in wide and 1.38 in high, with 0.036 in square pins, two-hole mounting for #4 screws (mounting screws not provided) and a weight of 0.53 lbs.

For 115 V operation the two primaries (pins 1-3 and 4-6) are connected in parallel; for 230 V they are connected in series. Joining secondary pin 9 to pin 10 places the windings in series, and that connection acts as the center tap.

The 183 Series is cUL listed; 183G12 is RoHS and REACH compliant.

Ideal For

  • 12.6 V C.T. or 6.3 V AC supply on a printed circuit board
  • Equipment wired for 115 VAC or 230 VAC at 50/60 Hz
  • Boards using the two secondaries separately

Overview

Series183 Series (Low Voltage PCB Mount - Universal - 2.5 VA to 56 VA)
DescriptionTransformer, low voltage PCB mount, 115/230V, 10VA, 12.6V C.T. @ 0.8A, 183 Series
Product TypeTransformer, low voltage PCB mount
Short DescriptionPOWER PCB 10VA 115/230
Bulk Pack Part No.183G12-BULK

Dimensions

Width (W)1.56 in
Height (H)1.38 in
Length (L)1.88 in
Dimension A0.20 in
Dimension B0.40 in
Dimension C1.14 in
Dimension M1.25 in
Pin Size (Square)0.036 in

Electrical

Hipot4,000V RMS
PrimaryDual primary, 115 / 230 VAC
CouplingLow primary to secondary coupling - no electrostatic shield required
Frequency50/60 Hz
Center TapSeries connection (pin 9 connected to pin 10) acts as the C.T. (center tap)
Primary Pins1, 3, 4, 6
Secondary Pins7, 9, 10, 12
Power Rating (VA)10
Secondary (RMS) Series12.6V C.T. @ 0.8A
Secondary ConfigurationDual winding secondaries, non-concentrically wound; can be wired in series, parallel or used separately
Secondary (RMS) Parallel6.3V @ 1.6A

Identifiers

UPC623980258690
UNSPSC39121301
Part Number183G12

Packaging & Shipping

Shipping Weight0.53 lbs (0.24 kg)
Unit Weight (Series Table, 10 VA)0.53 lbs

Construction & Finish

BobbinLow profile, split bobbin with top shroud design
MountingP.C. board mount with industry standard pin spacing
Mounting HolesTwo hole mounting (mounting screws not provided)
Mounting Screw#4
Insulation ClassClass F, 155 degrees C

Compliance & Certifications

RoHS CompliantYes
Series ListingcUL
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What output does the 183G12 provide?▾

It is rated 10 VA: 12.6V C.T. @ 0.8A with the secondaries connected in series, or 6.3V @ 1.6A with them connected in parallel. The windings can also be used separately.

Can it run on both 115 V and 230 V?▾

Yes. It has a universal dual primary for 50/60 Hz. Connect the two primary windings in parallel for 115 VAC or in series for 230 VAC.

Where is the center tap?▾

When the secondaries are connected in series by joining pin 9 to pin 10, that connection acts as the C.T. (center tap).

How big is the 183G12?▾

The series mounting table lists the 10 VA size at 1.88 in long, 1.56 in wide and 1.38 in high, with 0.036 in square pins, a #4 mounting screw and a weight of 0.53 lbs.

Are mounting screws included?▾

No. The 10 VA size uses two-hole mounting and the manufacturer states mounting screws are not provided; the specified screw is #4.

What listings and compliance does it have?▾

The 183 Series lists cUL. It is RoHS and REACH compliant.