Hammond 183F24 5VA 24V Center-Tapped PCB Power Transformer
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 5 VA rating: 24V C.T. @ 0.21A with secondaries in series, 12V @ 0.42A in parallel
- Universal dual primary: 115 VAC (parallel) or 230 VAC (series), 50/60 Hz
- Dual non-concentrically wound secondaries usable in series, parallel or separately
- Hipot 4,000 V RMS; Class F (155 °C) insulation; no electrostatic shield required
- Drawing dimensions L 1.625" x W 1.313" x H 1.360", 0.025 in square pins
- P.C. board mount, industry standard pin spacing, two-hole #4 screw mounting (screws not provided)
- cUL listed series; RoHS and REACH compliant
- Drawing test limits: Iex 41mA max. at 115 V, 60 Hz; 4000 V, 60 Hz, 1 s hipot
The 183F24 is a 5 VA low voltage PCB mount power transformer with a dual 115/230 V primary for 50/60 Hz mains. Its two 12 V, 210 mA secondary windings give 24 V C.T. at 0.21 A when wired in series or 12 V at 0.42 A when wired in parallel, a common pairing for 24 V and 12 V AC circuits on compact control and instrument boards.
Construction uses a low profile, split bobbin with a top shroud. The dual secondary windings are non-concentrically wound, giving low primary-to-secondary coupling so no electrostatic shield is required, and the transformer is hipot rated at 4,000 V RMS with Class F (155 °C) insulation.
The 183F24 drawing specifies L 1.625" ±0.063, W 1.313" ±0.063 and H 1.360" ±0.063, with 0.025" SQ. ±0.005 square pins and a #4 mounting screw (two-hole mounting; screws not provided); the series table lists the 5 VA size nominally as 1.63 x 1.44 x 1.38 in.
For 115 V operation the two primaries (pins 1-3 and 4-6) are connected in parallel; for 230 V they are connected in series. Joining secondary pin 9 to pin 10 places the windings in series, and that connection acts as the center tap. Test limits on the drawing include 41mA maximum excitation current at 115 V, 60 Hz and a 4000 V, 60 Hz, 1 second primary-to-secondary hipot.
The 183 Series is cUL listed; 183F24 is RoHS and REACH compliant.
Ideal For
- 24 V C.T. or 12 V AC supply mounted on a circuit board
- Equipment powered from 115 VAC or 230 VAC at 50/60 Hz
- Designs requiring published excitation-current and hipot test limits
Overview
| Series | 183 Series (Low Voltage PCB Mount - Universal - 2.5 VA to 56 VA) |
| Description | Transformer, low voltage PCB mount, 115/230V, 5VA, 24V C.T. @ 0.21A, 183 Series |
| Product Type | Transformer, low voltage PCB mount |
| Short Description | POWER PCB 5VA 115/230 |
| Bulk Pack Part No. | 183F24-BULK |
Dimensions
| A (Drawing) | 0.200" ±0.030 |
| B (Drawing) | 0.400" ±0.030 |
| C (Drawing) | 1.000" ±0.063 |
| H (Drawing) | 1.360" ±0.063 |
| J (Drawing) | 0.125" ±0.005 |
| L (Drawing) | 1.625" ±0.063 |
| M (Drawing) | 1.063" ±0.063 |
| W (Drawing) | 1.313" ±0.063 |
| Nominal Width (W) | 1.44 in |
| Nominal Height (H) | 1.38 in |
| Nominal Length (L) | 1.63 in |
| Nominal Dimension A | 0.20 in |
| Nominal Dimension B | 0.40 in |
| Nominal Dimension C | 1.00 in |
| Nominal Dimension M | 1.06 in |
| Pin Size G (Drawing) | 0.025" SQ. ±0.005 |
| Nominal Pin Size (Square) | 0.025 in |
Electrical
| Hipot | 4,000V RMS |
| Primary | Dual primary, 115 / 230 VAC |
| Coupling | Low primary to secondary coupling - no electrostatic shield required |
| Frequency | 50/60 Hz |
| Center Tap | Series connection (pin 9 connected to pin 10) acts as the C.T. (center tap) |
| Hipot Test | Primary - secondary 4000V, 60Hz, 1 sec |
| Primary Pins | 1, 3, 4, 6 |
| Secondary Pins | 7, 9, 10, 12 |
| Power Rating (VA) | 5 |
| Secondary (RMS) Series | 24V C.T. @ 0.21A |
| Secondary Configuration | Dual winding secondaries, non-concentrically wound; can be wired in series, parallel or used separately |
| Excitation Current (Iex) | 41mA max. @ 115V, 60Hz, pin 1 - pin 3 |
| Secondary (RMS) Parallel | 12V @ 0.42A |
| No-Load Voltage, Pin 4 - Pin 6 | 115.0V ±2% @ 115V, 60Hz on pin 1 - pin 3 |
| No-Load Voltage, Pin 7 - Pin 9 | 15.16V ±2% @ 115V, 60Hz on pin 1 - pin 3 |
| Primary Windings (Per Drawing) | 2 x 115V |
| No-Load Voltage, Pin 10 - Pin 12 | 14.79V ±2% @ 115V, 60Hz on pin 1 - pin 3 |
| Secondary Windings (Per Drawing) | 2 x 12V 210mA |
| DC Resistance @ 20°C, Pin 1 - Pin 3 | 302.4 ohm ±20% |
| DC Resistance @ 20°C, Pin 4 - Pin 6 | 362.6 ohm ±20% |
| DC Resistance @ 20°C, Pin 7 - Pin 9 | 6.145 ohm ±20% |
| DC Resistance @ 20°C, Pin 10 - Pin 12 | 4.862 ohm ±20% |
Identifiers
| UPC | 623980258881 |
| UNSPSC | 39121301 |
| Part Number | 183F24 |
Packaging & Shipping
| Shipping Weight | 0.37 lbs (0.17 kg) |
| Unit Weight (Drawing) | 0.37 lbs. approx. |
Construction & Finish
| Bobbin | Low profile, split bobbin with top shroud design |
| Mounting | P.C. board mount with industry standard pin spacing |
| Mounting Holes | Two hole mounting (mounting screws not provided) |
| Mounting Screw | #4 |
| Insulation Class | Class F, 155 degrees C |
Compliance & Certifications
| RoHS Compliant | Yes |
| Series Listing | cUL |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What output does the 183F24 provide?▾
It is rated 5 VA: 24V C.T. @ 0.21A with the secondaries connected in series, or 12V @ 0.42A with them connected in parallel. The windings can also be used separately.
Can it run on both 115 V and 230 V?▾
Yes. It has a universal dual primary for 50/60 Hz. Connect the two primary windings in parallel for 115 VAC or in series for 230 VAC.
Where is the center tap?▾
When the secondaries are connected in series by joining pin 9 to pin 10, that connection acts as the C.T. (center tap).
What are the dimensions of the 183F24?▾
The part drawing lists L 1.625" ±0.063, W 1.313" ±0.063, H 1.360" ±0.063, pin G 0.025" SQ. ±0.005 and a #4 mounting screw, with a weight of 0.37 lbs. approx. The series table lists the 5 VA size nominally as 1.63 x 1.44 x 1.38 in.
What electrical tests are specified?▾
The drawing specifies excitation current of 41mA max. at 115 V, 60 Hz (pin 1 - pin 3), no-load voltages of 15.16V (pins 7-9) and 14.79V (pins 10-12) at ±2%, DC resistances at 20 °C within ±20%, and a primary-to-secondary hipot of 4000 V, 60 Hz for 1 second.
Are mounting screws included?▾
No. The 5 VA size uses two-hole mounting and the manufacturer states mounting screws are not provided; the specified screw is #4.
Related Products

183F20-BULK — Transformer, low voltage PCB mount, 115/230V, 5VA, 20V C.T. @ 0.25A, 183 Series
Hammond Manufacturing · 183F20-BULK

183F24-BULK — Transformer, low voltage PCB mount, 115/230V, 5VA, 24V C.T. @ 0.21A, 183 Series
Hammond Manufacturing · 183F24-BULK
Save 52%183F20 — Transformer, low voltage PCB mount, 115/230V, 5VA, 20V C.T. @ 0.25A, 183 Series
Hammond Manufacturing · 183F20
Save 52%183F28 — Transformer, low voltage PCB mount, 115/230V, 5VA, 28V C.T. @ 0.18A, 183 Series
Hammond Manufacturing · 183F28

183F16-BULK — Transformer, low voltage PCB mount, 115/230V, 5VA, 16V C.T. @ 0.31A, 183 Series
Hammond Manufacturing · 183F16-BULK