Hammond 182S24 500VA 48V CT Toroidal Chassis Mount Transformer
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Hammond Manufacturing 182S24.
224-955-1644Key Features
- 500 VA toroidal transformer with dual secondary: 48V C.T. @ 10.42A series or 24V @ 20.82A parallel
- Dual 117/234 VAC primary for 50/60 Hz operation (parallel for 117V, series for 234V)
- 5.50 in (140 mm) diameter by 2.21 in (56 mm) high low-profile toroid
- Potted center with single-hole mounting; 1/4-20 x 2.50 in center bolt supplied
- Supplied with one bottom rubber insulating pad and mounting hardware
- Hi-Pot tested at 4,000V RMS between primary and secondary; minimum 8" flexible leads
- CSA C22.2 #66, UL506 recognized and CE (IEC950) certified; RoHS and REACH compliant
- Discontinued as a stocked series; replacement part listed as 1182S4
The 182S24 is a 500 VA low-voltage toroidal power transformer for chassis mounting, from the 182 Series. Its dual secondary delivers 48V C.T. @ 10.42A when the windings are connected in series, or 24V @ 20.82A when they are connected in parallel, making it a fit for OEM engineers and equipment builders who need a 48V centre-tapped or 24V supply from a single core.
The primary is a dual 117/234 VAC winding for 50/60 Hz operation: wire the two primary halves in parallel for 117 VAC or in series for 234 VAC. The manufacturer's short description for this part reads "REPLACED WITH 1182S4". The toroidal design is described as low profile, lightweight and cool running thanks to its high efficiency, and the units are designed to have all windings engaged. Flexible leads are a minimum of 8" long, and every unit is Hi-Pot tested at 4,000V RMS between primary and secondary.
Physically, the 182S24 measures 5.50 in (140 mm) in outside diameter and 2.21 in (56 mm) high, with a table weight of 8.46 lbs and a listed shipping weight of 8.46 lbs (3.84 kg). It uses center single-hole mounting through a potted center for extra mounting strength, and ships with one bottom rubber insulating pad and mounting hardware: a 1/4-20 center bolt 2.50 in (64 mm) long (bottom rubber washer only, no top steel washer).
The series is CSA certified to C22.2 #66 (CSA file #209651), UL recognized to UL506 (UL file #E207860) and CE certified to IEC950, and this part is listed as RoHS and REACH compliant. Because toroidal transformers can draw a high magnetizing inrush current when first energized, the manufacturer advises a slow-blow fuse, time-delayed circuit breaker or other soft-start circuitry on the supply line.
Note: the 182 Series will soon be discontinued as a stocked series and is available while quantities last. The manufacturer lists 1182S4 as the replacement for the 182S24, within the 1182 Series.
Ideal For
- 48V center-tapped or 24V low-voltage power supplies
- 500 VA chassis-mounted power for equipment builds
- Dual-voltage 117/234 VAC equipment for global use
- OEM replacement of 182 Series toroidal transformers
Mounting
| Washers | Bottom Rubber Washer Only |
| Included Items | One bottom rubber insulating pad and mounting hardware |
| Mounting Method | Center single hole mounting |
| Included Mounting Hardware Length | 2.50 in (64 mm) |
| Included Mounting Hardware Thread | 1/4-20 |
Overview
| Series | 182 Series |
| Product Type | Toroidal low-voltage power transformer, chassis mount |
| Replacement Part | 1182S4 |
| Availability Note | 182 Series will soon be discontinued as a stocked series; available while quantities last; replaced with 1182 Series |
| Short Description | REPLACED WITH 1182S4 |
Dimensions
| Height | 2.21 in (56 mm) |
| Weight (Table) | 8.46 lbs |
| Outside Diameter | 5.50 in (140 mm) |
Electrical
| Frequency | 50/60 Hz |
| Hi-Pot Test | 4,000V RMS between primary & secondary |
| Power Rating | 500 VA |
| Winding Note | Units are designed to have all windings engaged |
| Secondary Type | Dual |
| Primary Voltage | Dual 117/234 VAC |
| Inrush Current Note | Use a slow-blow fuse, time delayed circuit breaker or other soft start circuitry on the supply line |
| Primary Wiring For 117V | Parallel connection |
| Primary Wiring For 234V | Series connection |
| Secondary (RMS), Series | 48V C.T. @ 10.42A |
| Secondary (RMS), Parallel | 24V @ 20.82A |
Identifiers
| UPC | 623980272474 |
| UNSPSC | 39121301 |
| Part Number | 182S24 |
Packaging & Shipping
| Shipping Weight | 8.46 lbs (3.84 kg) |
Construction & Finish
| Leads | Minimum 8" long flexible leads |
| Core Type | Toroidal |
| Toroid Center | Potted |
Compliance & Certifications
| CE | Certified to IEC950 |
| UL | Recognized to UL506 - UL file #E207860 |
| CSA | Certified to C22.2 #66 - CSA file #209651 |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What output voltages does the 182S24 provide?▾
With the two secondary windings in series it provides 48V C.T. @ 10.42A; with them in parallel it provides 24V @ 20.82A.
Can the 182S24 run on both 117V and 234V supplies?▾
Yes. It has a dual 117/234 VAC primary for 50/60 Hz operation: connect the primary windings in parallel for 117 VAC or in series for 234 VAC.
How is the 182S24 mounted and what hardware is included?▾
It uses center single-hole mounting through a potted center. It is supplied with one bottom rubber insulating pad and mounting hardware, a 1/4-20 bolt 2.50 in (64 mm) long.
What are the dimensions and weight of the 182S24?▾
Outside diameter is 5.50 in (140 mm) and height is 2.21 in (56 mm). The ordering table lists 8.46 lbs and the shipping weight is 8.46 lbs (3.84 kg).
Why might the breaker trip when this transformer is switched on?▾
Toroidal transformers can draw high magnetizing current when first energized, limited only by the primary's low DC resistance; the overload rarely lasts longer than half a cycle. A slow-blow fuse, time delayed breaker or soft start circuit is recommended.
Is the 182S24 still available, and what replaces it?▾
The 182 Series will soon be discontinued as a stocked series and is available while quantities last. The manufacturer lists 1182S4 as the replacement.
Related Products
Save 52%182S15 — Toroid, 300VA, 50HZ, 15/15V
Hammond Manufacturing · 182S15

182S30 — Replaced With 1182S30
Hammond Manufacturing · 182S30

182S12 — Toroid, 225VA, 50HZ, 12/12V
Hammond Manufacturing · 182S12

182T117 — Replaced With 1182T117
Hammond Manufacturing · 182T117
Save 52%182S110 — Toroid, 1000VA, 50HZ, 110/110V
Hammond Manufacturing · 182S110