(224) 955-1644
Hammond ManufacturingAuthorized partner store
167J36 enclosed chassis mount power transformer, 36 V C.T. 1 A, 36 VA

Hammond 167J36 36V CT 1A Enclosed Chassis Transformer, 36 VA

Hammond Manufacturing|

MPN: 167J36

|

UPC: 623980243108

In Stock
$28.51

Ships from and sold by A5 IT

Ground Shipping · $18.67Arrives by Monday, Oct 26
Order within 49m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 36 VA rating with 36 V C.T. secondary at 1 A (RMS)
  • 115 VAC, 60 Hz primary
  • Enclosed housing with 4 hole chassis mount
  • Compact A 2.19 x B 2.38 x C 2.63 in body with 0.19 x 0.25 in mounting slots
  • Class B insulation (130 °C); hi-pot tested at 2,000V RMS
  • Dual bobbin design - no electrostatic shield required
  • UL listed (# E50394) and CSA certified (209651); RoHS and REACH compliant
  • Published test limits: excitation current 118mA Max., no-load secondary 39.90V ±2%

The 167J36 is a 36 VA enclosed chassis mount power transformer that delivers 36 V centre-tapped at 1 A from a 115 VAC, 60 Hz primary. It suits small split-rail DC supplies, control electronics and low-voltage AC circuits, and its drawing publishes full electrical acceptance data for incoming inspection.

It follows the 167 Series construction: an enclosed housing, a dual bobbin design that needs no electrostatic shield, Class B insulation rated 130 °C, and a hi-pot test of 2,000V RMS. All secondaries in the series are centre tapped, and leads are a minimum of 6 in long. Per the drawing, secondary no-load voltage is 39.90 V ±2% across GRN - GRN (19.95 V ±2% to the GRN/YEL centre tap), with primary excitation current of 118 mA maximum.

The ordering table lists the 167J36 at A 2.19 in (56 mm), B 2.38 in (60 mm), C 2.63 in (67 mm), D 1.75 in (44 mm) and E 1.31 in (33 mm), with 0.19 x 0.25 in (5 x 6 mm) mounting slots for its 4 hole chassis mount. Shipping weight is 1.4 lbs (0.64 kg).

Drawing acceptance data at 20 °C gives a primary DC resistance of 14.45 ±20% (BLK - BLK) and a secondary DC resistance of 1.930 ±20% (GRN - GRN); the primary leads are black, the secondary leads green, and the centre tap green/yellow. The hi-pot test is 2000V, 60Hz for 1 second, primary to secondary.

The transformer is UL listed (# E50394) and CSA certified (209651), and it is declared RoHS and REACH compliant. Confirm your supply matches the 115 VAC, 60 Hz primary before installing.

Ideal For

  • Rectified DC power supplies
  • Split 18 V rails from a 36 V C.T. winding
  • Control and instrumentation circuits
  • OEM chassis-mounted equipment power

Mounting

Mounting StyleEnclosed, 4 hole chassis mount
Mounting Slot G0.19 in (5 mm) x 0.25 in (6 mm); drawing 0.188" X 0.250" ±0.015

Overview

StyleEnclosed, chassis mount
Series167 Series
Product TypePower Transformer - Low Voltage, Filament
Short DescriptionFIL-RECT 36VA 115 36VCT
Manufacturer DescriptionPower transformer, low voltage, enclosed chassis mount, 36VA 115 36VCT

Dimensions

Dimension A2.19 in (56 mm); drawing 2.188" ±0.063
Dimension B2.38 in (60 mm); drawing 2.375" ±0.125
Dimension C2.63 in (67 mm); drawing 2.625" ±0.063
Dimension D1.75 in (44 mm); drawing 1.750" ±0.063
Dimension E1.31 in (33 mm); drawing 1.313" ±0.063

Electrical

Hi-Pot Test2,000V RMS; primary - secondary 2000V, 60Hz, 1 sec (drawing)
Lead ColoursPrimary BLK / BLK; secondary GRN / GRN; centre tap GRN/YEL
Power Rating36 VA
Primary Voltage115 VAC, 60 Hz.
Winding ConstructionDual bobbin design - no electrostatic shield required
Secondary Current (RMS)1 A
Secondary Voltage (RMS)36 VAC C.T. (center tapped)
Excitation Current (Iex)118mA Max. @ 115V, 60Hz, BLK - BLK
DC Resistance, Primary (BLK - BLK)14.45 ±20% @ 20°C
DC Resistance, Secondary (GRN - GRN)1.930 ±20% @ 20°C
Secondary No-Load Voltage, GRN - GRN39.90V ±2% @ 115V, 60Hz
Secondary No-Load Voltage, GRN - GRN/YEL = GRN/YEL - GRN19.95V ±2% @ 115V, 60Hz

Identifiers

UPC623980243108
UNSPSC39121301
Part Number167J36

Packaging & Shipping

Shipping Weight1.4 lbs (0.64 kg)

Construction & Finish

LeadsMinimum 6 in long (series); drawing: 6" out min., stripped 0.5"
Insulation ClassClass B (130 °C)

Compliance & Certifications

ULUL listed (# E50394)
CSACSA certified (209651)
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What is the output of the 167J36?▾

The 167J36 provides a 36 V centre-tapped (C.T.) RMS secondary rated at 1 A, for a power rating of 36 VA.

What input voltage does the 167J36 accept?▾

The primary is rated 115 VAC, 60 Hz.

How is the 167J36 mounted?▾

It is an enclosed transformer with a 4 hole chassis mount; the mounting slots measure 0.19 x 0.25 in (5 x 6 mm).

What certifications does it carry?▾

It is UL listed (# E50394) and CSA certified (209651), and it is RoHS and REACH compliant.

What insulation and testing does it have?▾

It uses Class B insulation (130 °C) and is hi-pot tested at 2,000V RMS. The dual bobbin design means no electrostatic shield is required.

What no-load voltage should I measure on the 167J36?▾

The drawing specifies 39.90V ±2% across GRN - GRN and 19.95V ±2% from each GRN lead to the GRN/YEL centre tap, measured with 115V, 60Hz applied BLK - BLK.