Key Features

  • 288 VA rating with 24 V C.T. secondary at 12 A (RMS)
  • Single primary rated 117V 50/60 Hz.
  • Chassis mount on channel bracket, mounting reference B with 0.203 x 0.375 in holes
  • Class B (130 °C) insulation; UL listed as a Class A (105 °C) design
  • Dual bobbin design - no electrostatic shield required
  • Hi-Pot tested at 2,000V RMS; minimum 6 in long leads
  • UL listed, CSA certified, RoHS and REACH compliant
  • Overall size A 3.75 x B 3.60 x C 4.63 in; ships at 9.85 lbs (4.47 kg)

The 166T24 is the 288 VA top end of the 166 Series: a power transformer with a 117 V, 50/60 Hz primary and a 24 V centre-tapped secondary rated at 12 A. The 50/60 Hz primary rating and 288 VA capacity make it suited to larger low-voltage supplies in industrial controls, audio and OEM equipment.

Construction follows the 166 Series design: an open style unit on a channel bracket, a dual bobbin winding arrangement that needs no electrostatic shield, and Class B insulation rated to 130 °C for extra protection, while the transformer is UL listed as a Class A (105 °C) design. Every unit is hi-pot tested at 2,000V RMS, and it is supplied with minimum 6 in long leads. Unlike the smaller two-hole parts in the series, the 166T24 uses mounting reference B with both D and E hole-to-hole dimensions and mounting holes of 0.203 in width-wise by 0.375 in depth-wise.

Overall dimensions are A 3.75 in (95 mm), B 3.60 in (91 mm) and C 4.63 in (118 mm). The 166T24 uses mounting reference B, with hole-to-hole spacings D and E of 3.00 in (76 mm) each and mounting holes of 0.203 in (5.2 mm) width-wise by 0.375 in (9.5 mm) depth-wise. Shipping weight is 9.85 lbs (4.47 kg). On the drawing schematic the primary leads are black (BLK/BLK) and the secondary leads are green (GRN/GRN) with a green/yellow (GRN/YEL) centre tap.

The transformer is UL listed and CSA certified, and it is declared RoHS and REACH compliant. Its primary is rated 117 V, 50/60 Hz, so confirm this suits your supply; for 117/234 V dual-primary operation or dual secondaries, the manufacturer points to its 266 Series.

Ideal For

  • Filament and heater supplies
  • Low voltage 24 V C.T. AC supply rails
  • Rectified low-voltage DC power supplies
  • OEM chassis-mounted equipment power

Mounting

Mounting StyleChassis mount, channel bracket
Mounting ReferenceB
Mounting Hole Size (Depth-wise)0.375 in / 9.5 mm (table: 0.38 in (10 mm))
Mounting Hole Size (Width-wise)0.203 in / 5.2 mm (table: 0.20 in (5 mm))
Hole-to-Hole Mounting Dimension D3.00 in (76 mm); drawing 3 in / 76.2 mm
Hole-to-Hole Mounting Dimension E3.00 in (76 mm); drawing 3 in / 76.2 mm

Overview

StyleOpen style, channel bracket, chassis mount
Series166 Series - Economical Single Primary
Product TypePower Transformer - Low Voltage/Filament
Short DescriptionPOWER TX 117VAC - 24V@ 12A
Manufacturer DescriptionPower transformer, low voltage, 117V 50/60 Hz., 288VA, 24 C.T., 12A

Dimensions

Overall Dimension A3.75 in (95 mm); drawing 3.75 in / 95.3 mm
Overall Dimension B3.60 in (91 mm); drawing 3.6 in / 91.4 mm
Overall Dimension C4.63 in (118 mm); drawing 4.63 in / 117.6 mm

Electrical

Hi-Pot Test2,000V RMS
Power Rating288 VA
Primary TypeSingle primary
Primary Voltage117V 50/60 Hz.
Winding ConstructionDual bobbin design - no electrostatic shield required
Secondary Current (RMS)12 A
Secondary Voltage (RMS)24 VAC C.T. (center tapped)

Identifiers

UPC623980036717
UNSPSC39121301
Part Number166T24

Packaging & Shipping

Shipping Weight9.85 lbs (4.47 kg)

Construction & Finish

LeadsMinimum 6 in long
Insulation ClassClass B (130 °C); UL listed as a Class A (105 °C) design

Compliance & Certifications

ULUL listed
CSACSA certified
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What output does the 166T24 provide?▾

The 166T24 has a 24 V centre-tapped (C.T.) RMS secondary rated at 12 A, for a power rating of 288 VA.

What primary voltage does the 166T24 need?▾

Its single primary is rated 117V 50/60 Hz. For 117/234 V operation or dual secondaries the manufacturer suggests its 266 Series.

How is the 166T24 mounted?▾

It is an open style, channel bracket chassis mount unit using mounting reference B: hole-to-hole dimensions D and E are both 3.00 in (76 mm), and the mounting holes measure 0.203 in (5.2 mm) width-wise and 0.375 in (9.5 mm) depth-wise.

What are the overall dimensions of the 166T24?▾

Overall dimension A is 3.75 in (95 mm), B is 3.60 in (91 mm) and C is 4.63 in (118 mm). The shipping weight is 9.85 lbs (4.47 kg).

Which certifications does it carry?▾

It is UL listed (as a Class A, 105 °C design using Class B, 130 °C insulation) and CSA certified, and it is RoHS and REACH compliant.

Does it need an electrostatic shield?▾

No. The dual bobbin design means no electrostatic shield is required. Units are hi-pot tested at 2,000V RMS.