Hammond 166T24 24V CT 12A Power Transformer, 288 VA, 117V 50/60 Hz
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 288 VA rating with 24 V C.T. secondary at 12 A (RMS)
- Single primary rated 117V 50/60 Hz.
- Chassis mount on channel bracket, mounting reference B with 0.203 x 0.375 in holes
- Class B (130 °C) insulation; UL listed as a Class A (105 °C) design
- Dual bobbin design - no electrostatic shield required
- Hi-Pot tested at 2,000V RMS; minimum 6 in long leads
- UL listed, CSA certified, RoHS and REACH compliant
- Overall size A 3.75 x B 3.60 x C 4.63 in; ships at 9.85 lbs (4.47 kg)
The 166T24 is the 288 VA top end of the 166 Series: a power transformer with a 117 V, 50/60 Hz primary and a 24 V centre-tapped secondary rated at 12 A. The 50/60 Hz primary rating and 288 VA capacity make it suited to larger low-voltage supplies in industrial controls, audio and OEM equipment.
Construction follows the 166 Series design: an open style unit on a channel bracket, a dual bobbin winding arrangement that needs no electrostatic shield, and Class B insulation rated to 130 °C for extra protection, while the transformer is UL listed as a Class A (105 °C) design. Every unit is hi-pot tested at 2,000V RMS, and it is supplied with minimum 6 in long leads. Unlike the smaller two-hole parts in the series, the 166T24 uses mounting reference B with both D and E hole-to-hole dimensions and mounting holes of 0.203 in width-wise by 0.375 in depth-wise.
Overall dimensions are A 3.75 in (95 mm), B 3.60 in (91 mm) and C 4.63 in (118 mm). The 166T24 uses mounting reference B, with hole-to-hole spacings D and E of 3.00 in (76 mm) each and mounting holes of 0.203 in (5.2 mm) width-wise by 0.375 in (9.5 mm) depth-wise. Shipping weight is 9.85 lbs (4.47 kg). On the drawing schematic the primary leads are black (BLK/BLK) and the secondary leads are green (GRN/GRN) with a green/yellow (GRN/YEL) centre tap.
The transformer is UL listed and CSA certified, and it is declared RoHS and REACH compliant. Its primary is rated 117 V, 50/60 Hz, so confirm this suits your supply; for 117/234 V dual-primary operation or dual secondaries, the manufacturer points to its 266 Series.
Ideal For
- Filament and heater supplies
- Low voltage 24 V C.T. AC supply rails
- Rectified low-voltage DC power supplies
- OEM chassis-mounted equipment power
Mounting
| Mounting Style | Chassis mount, channel bracket |
| Mounting Reference | B |
| Mounting Hole Size (Depth-wise) | 0.375 in / 9.5 mm (table: 0.38 in (10 mm)) |
| Mounting Hole Size (Width-wise) | 0.203 in / 5.2 mm (table: 0.20 in (5 mm)) |
| Hole-to-Hole Mounting Dimension D | 3.00 in (76 mm); drawing 3 in / 76.2 mm |
| Hole-to-Hole Mounting Dimension E | 3.00 in (76 mm); drawing 3 in / 76.2 mm |
Overview
| Style | Open style, channel bracket, chassis mount |
| Series | 166 Series - Economical Single Primary |
| Product Type | Power Transformer - Low Voltage/Filament |
| Short Description | POWER TX 117VAC - 24V@ 12A |
| Manufacturer Description | Power transformer, low voltage, 117V 50/60 Hz., 288VA, 24 C.T., 12A |
Dimensions
| Overall Dimension A | 3.75 in (95 mm); drawing 3.75 in / 95.3 mm |
| Overall Dimension B | 3.60 in (91 mm); drawing 3.6 in / 91.4 mm |
| Overall Dimension C | 4.63 in (118 mm); drawing 4.63 in / 117.6 mm |
Electrical
| Hi-Pot Test | 2,000V RMS |
| Power Rating | 288 VA |
| Primary Type | Single primary |
| Primary Voltage | 117V 50/60 Hz. |
| Winding Construction | Dual bobbin design - no electrostatic shield required |
| Secondary Current (RMS) | 12 A |
| Secondary Voltage (RMS) | 24 VAC C.T. (center tapped) |
Identifiers
| UPC | 623980036717 |
| UNSPSC | 39121301 |
| Part Number | 166T24 |
Packaging & Shipping
| Shipping Weight | 9.85 lbs (4.47 kg) |
Construction & Finish
| Leads | Minimum 6 in long |
| Insulation Class | Class B (130 °C); UL listed as a Class A (105 °C) design |
Compliance & Certifications
| UL | UL listed |
| CSA | CSA certified |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What output does the 166T24 provide?▾
The 166T24 has a 24 V centre-tapped (C.T.) RMS secondary rated at 12 A, for a power rating of 288 VA.
What primary voltage does the 166T24 need?▾
Its single primary is rated 117V 50/60 Hz. For 117/234 V operation or dual secondaries the manufacturer suggests its 266 Series.
How is the 166T24 mounted?▾
It is an open style, channel bracket chassis mount unit using mounting reference B: hole-to-hole dimensions D and E are both 3.00 in (76 mm), and the mounting holes measure 0.203 in (5.2 mm) width-wise and 0.375 in (9.5 mm) depth-wise.
What are the overall dimensions of the 166T24?▾
Overall dimension A is 3.75 in (95 mm), B is 3.60 in (91 mm) and C is 4.63 in (118 mm). The shipping weight is 9.85 lbs (4.47 kg).
Which certifications does it carry?▾
It is UL listed (as a Class A, 105 °C design using Class B, 130 °C insulation) and CSA certified, and it is RoHS and REACH compliant.
Does it need an electrostatic shield?▾
No. The dual bobbin design means no electrostatic shield is required. Units are hi-pot tested at 2,000V RMS.
Related Products
Save 52%166S6 — Power transformer, low voltage, 115V 60 Hz., 63VA, 6.3 C.T., 10A
Hammond Manufacturing · 166S6
Save 52%166U5 — Power transformer, low voltage, 115V 60 Hz., 75VA, 5 C.T., 15A
Hammond Manufacturing · 166U5
Save 52%166S5 — Power transformer, low voltage, 115V 60 Hz., 50VA, 5 C.T., 10A
Hammond Manufacturing · 166S5
Save 52%166U7 — Power transformer, low voltage, 115V 60 Hz., 112.5VA, 7.5 C.T., 15A
Hammond Manufacturing · 166U7
Save 52%166S2 — Power transformer, low voltage, 115V 60 Hz., 25VA, 2.5 C.T., 10A
Hammond Manufacturing · 166S2