166N18 18V C.T. 4A 72 VA open-style chassis mount power transformer with leads

Hammond 166N18 18V C.T. 4A 72VA Power Transformer

Hammond Manufacturing|

MPN: 166N18

|

UPC: 623980474724

In Stock
$20.66

Ships from and sold by A5 IT

Ground Shipping · $18.67Arrives by Monday, Oct 26
Order within 2h 46m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 72 VA rating with 18 V center-tapped secondary at 4 A RMS
  • 115V 60 Hz. single primary
  • Open style, channel bracket, two hole chassis mount (mounting ref C)
  • Overall 4.03 in (102 mm) x 2.25 in (57 mm) x 2.63 in (67 mm) (A x B x C)
  • Class B (130 °C) insulation; UL listed as a Class A (105 °C) design
  • Dual bobbin design - no electrostatic shield required
  • Hi-Pot tested at 2,000V RMS; minimum 6 in long leads
  • UL listed and CSA certified; RoHS and REACH compliant

The 166N18 is a low voltage/filament power transformer from the 166 Series, rated 72 VA with a 115V 60 Hz. primary and a 18 V center-tapped (C.T.) secondary rated 4 A RMS. It is built for OEM engineers, panel builders and repair technicians who need an open style, channel bracket, two hole chassis mount transformer to derive a low AC voltage inside equipment. The 166N18 steps 115V 60 Hz down to 18 V C.T. at 4 A, a 72 VA rating, in a frame with a 4.03 in (102 mm) A dimension.

Construction follows the 166 Series design: a dual bobbin winding arrangement, so no electrostatic shield is required, and Class B insulation (130 °C) for extra protection, with the design UL listed as Class A (105 °C). Each unit is Hi-Pot tested at 2,000V RMS. Leads are a minimum of 6 in long.

Overall dimensions from the series ordering table are A 4.03 in (102 mm), B 2.25 in (57 mm) and C 2.63 in (67 mm), with a D dimension of 3.56 in (90 mm) and 0.19 in (5 mm) mounting holes (mounting reference C). The shipping weight is 1.4 lbs (0.64 kg).

The 166 Series is UL listed and CSA certified, and the 166N18 is marked RoHS compliant and REACH compliant. Identifiers include UPC 623980474724 and UNSPSC 39121301. If you need 117/234V or 50/60 Hz operation or dual secondaries, the manufacturer points to its 266 Series instead.

Ideal For

  • Low voltage 18 V AC supply from a 115V 60 Hz line
  • Filament and low voltage transformer applications
  • 72 VA chassis-mounted power supplies in OEM equipment
  • Circuits that need a center-tapped secondary

Mounting

Dimension D3.56 in (90 mm)
Mounting StyleOpen style, channel bracket, two hole chassis mount
Mounting ReferenceC
Mounting Dimensions0.19 in (5 mm)

Overview

Series166 Series - Low Voltage/Filament, Economical Single Primary
DescriptionPower transformer, low voltage, 115V 60 Hz., 72VA, 18 C.T., 4A
Part Number166N18
Product TypePower transformer, low voltage
Short DescriptionPOWER

Dimensions

Overall Dimension A4.03 in (102 mm)
Overall Dimension B2.25 in (57 mm)
Overall Dimension C2.63 in (67 mm)

Electrical

Hi-Pot Test2,000V RMS
Power Rating72 VA
Winding DesignDual bobbin - no electrostatic shield required
Primary Voltage115V 60 Hz.
Secondary Current (RMS)4 A
Secondary Voltage (RMS)18 C.T. VAC

Identifiers

UPC623980474724
UNSPSC39121301

Packaging & Shipping

Shipping Weight1.4 lbs (0.64 kg)

Construction & Finish

LeadsMinimum 6 in long
InsulationClass B (130 °C)

Compliance & Certifications

ULUL listed (as a Class A, 105 °C design)
CSACSA certified
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What are the input and output ratings of the 166N18?▾

The 166N18 has a 115V 60 Hz. primary and a 18 V center-tapped secondary (RMS) rated 4 A, for a power rating of 72 VA.

Can the 166N18 run on 50 Hz power?▾

The 166N18 is specified for a 115V 60 Hz primary. For 117/234V or 50/60 Hz operation, the manufacturer recommends its 266 Series.

What size is the 166N18?▾

The series ordering table lists overall dimensions A 4.03 in (102 mm), B 2.25 in (57 mm) and C 2.63 in (67 mm), D 3.56 in (90 mm), with 0.19 in (5 mm) mounting dimensions (mounting reference C). Shipping weight is 1.4 lbs (0.64 kg).

How is the 166N18 mounted and wired?▾

It is an open style, channel bracket, two hole chassis mount transformer with leads a minimum of 6 in long.

What safety approvals does the 166N18 have?▾

The 166 Series is UL listed (as a Class A, 105 °C design, while using Class B 130 °C insulation) and CSA certified, and is Hi-Pot tested at 2,000V RMS. The 166N18 is also RoHS and REACH compliant.