166L2 open style chassis mount power transformer with channel bracket and wire leads, 2.5 V C.T. 2.5 A secondary

Hammond 166L2 2.5V CT 2.5A Power Transformer, 6.25 VA

Hammond Manufacturing|

MPN: 166L2

|

UPC: 623980221205

In Stock
$16.83

Ships from and sold by A5 IT

Ground Shipping · $16.89Arrives by Monday, Oct 26
Order within 2h 51m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 115V 60 Hz. primary; 2.5 V C.T. secondary rated 2.5 A RMS (6.25 VA)
  • Open style, channel bracket, two-hole chassis mount
  • Overall A x B x C: 2.81 x 1.50 x 1.69 in; 2.38 in hole-to-hole mounting (D)
  • Dual bobbin design - no electrostatic shield required
  • Class B (130 °C) insulation; UL listed as a Class A (105 °C) design
  • Minimum 6 in long leads
  • Hi-pot tested at 2,000V RMS; UL listed and CSA certified
  • RoHS and REACH compliant

The 166L2 is a low voltage/filament power transformer from the 166 Series of economical single-primary, open style chassis mount transformers. It takes a 115V 60 Hz. primary and delivers a 2.5 V center-tapped (C.T.) secondary rated 2.5 A RMS, for a power rating of 6.25 VA. It suits OEM engineers, equipment builders and technicians who need a compact line-to-low-voltage transformer that bolts directly to a chassis. At 2.5 A it sits between the 166K2 (1.5 A) and 166M2 (3 A) 2.5 V C.T. models, sharing the 166M2 body dimensions.

Construction is open style with a channel bracket and two-hole chassis mounting. A dual bobbin design means no electrostatic shield is required, and the series uses Class B insulation (130 °C) for extra protection, while the design is UL listed as Class A (105 °C). Leads are a minimum of 6 in long. The drawing schematic shows black primary leads and green secondary leads, with a green/yellow center-tap lead.

Overall dimensions from the series table are A 2.81 in (71 mm), B 1.50 in (38 mm) and C 1.69 in (43 mm), with a D (hole-to-hole mounting) dimension of 2.38 in (60 mm); the mounting dimension column lists 0.19 in (5 mm) (mounting ref. C). The part drawing gives A 2.81 in / 71.4 mm, B 1.5 in / 38.1 mm, C 1.69 in / 42.9 mm, D 2.38 in / 60.5 mm and a width-wise mounting hole size of 0.187 in / 4.7 mm. Shipping weight is 0.7 lbs (0.32 kg).

The 166 Series is hi-pot tested at 2,000V RMS, UL listed and CSA certified, and this part is listed as RoHS and REACH compliant. For 117/234 V or 50/60 Hz operation or dual secondaries, the series literature points to the 266 Series instead.

Ideal For

  • Low voltage and filament supplies from a 115V 60 Hz. line
  • Chassis-mounted power supplies needing 2.5 V C.T. at up to 2.5 A
  • Circuits that use a center-tapped 2.5 V secondary
  • OEM equipment and control panels requiring a 6.25 VA transformer

Mounting

Mounting StyleOpen style, channel bracket, two-hole chassis mount
Mounting ReferenceC
Mounting Hole Size (Width-wise)0.187 in / 4.7 mm
Mounting Dimension (Series Table)0.19 in (5 mm)

Overview

StyleOpen Style, Chassis Mount
Series166 Series - Low Voltage/Filament - Economical Single Primary
Part Number166L2
Product TypePower transformer, low voltage
Long DescriptionPower transformer, low voltage, 115V 60 Hz., 6.25VA, 2.5 C.T., 2.5A
Short DescriptionPOWER TX 115VAC - 2.5V@2.5A

Dimensions

Overall Dimension A2.81 in (71 mm)
Overall Dimension B1.50 in (38 mm)
Overall Dimension C1.69 in (43 mm)
Dimension A (Drawing)2.81 in / 71.4 mm
Dimension B (Drawing)1.5 in / 38.1 mm
Dimension C (Drawing)1.69 in / 42.9 mm
Hole-to-Hole Mounting (D)2.38 in (60 mm)
Hole-to-Hole Mounting D (Drawing)2.38 in / 60.5 mm

Electrical

InsulationClass B (130 °C); UL listed as a Class A (105 °C) design
Power Rating6.25 VA
Primary Voltage115V 60 Hz.
Electrostatic ShieldNot required (dual bobbin design)
Secondary Current (RMS)2.5 A
Secondary Voltage (RMS)2.5 C.T. VAC
Hi-Pot Test (Series Specification)2,000V RMS

Identifiers

UPC623980221205
UNSPSC39121301

Packaging & Shipping

Shipping Weight0.7 lbs (0.32 kg)

Construction & Finish

LeadsMinimum 6 in long
BobbinDual bobbin design

Compliance & Certifications

ULUL listed
CSACSA certified
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What input voltage does the 166L2 require?▾

The 166L2 has a single primary rated 115V 60 Hz.. For 117/234 V or 50/60 Hz operation, the series literature directs buyers to the 266 Series.

What is the secondary output of the 166L2?▾

It provides 2.5 VAC RMS with a center tap (C.T.) at 2.5 A, a power rating of 6.25 VA.

How is the 166L2 mounted and what are its dimensions?▾

It is an open style transformer with a channel bracket for two-hole chassis mounting. Overall dimensions are A 2.81 in (71 mm), B 1.50 in (38 mm), C 1.69 in (43 mm), with 2.38 in (60 mm) between mounting holes (D); the drawing lists a 0.187 in / 4.7 mm width-wise mounting hole.

Is the 166L2 UL listed and CSA certified?▾

Yes. The 166 Series is UL listed (as a Class A, 105 °C design, while using Class B 130 °C insulation) and CSA certified. The 166L2 is also listed as RoHS and REACH compliant.

Does the 166L2 need an electrostatic shield?▾

No. The series uses a dual bobbin design, so no electrostatic shield is required. The series is hi-pot tested at 2,000V RMS.

How long are the leads on the 166L2?▾

Leads are a minimum of 6 in long. Per the schematic, primary leads are black and secondary leads are green, with a green/yellow center tap.