(224) 955-1644
Hammond ManufacturingAuthorized partner store
166JB12 open style chassis mount power transformer with channel bracket and wire leads, 12 V 1.2 A secondary

Hammond 166JB12 12V 1.2A Power Transformer, 117V 50/60Hz Primary

Hammond Manufacturing|

MPN: 166JB12

|

UPC: 623980024660

In Stock
$12.24

Ships from and sold by A5 IT

Ground Shipping · $16.89Arrives by Monday, Oct 26
Order within 1h 10m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 117V 50/60 Hz. primary; 12 V secondary rated 1.2 A RMS (14.4 VA)
  • Open style, channel bracket, two-hole chassis mount
  • Overall A x B x C: 3.25 x 1.75 x 2.00 in; 2.81 in hole-to-hole mounting (D)
  • Dual bobbin design - no electrostatic shield required
  • Class B (130 °C) insulation; UL listed as a Class A (105 °C) design
  • Minimum 6 in long leads
  • Hi-pot tested at 2,000V RMS; UL listed and CSA certified
  • RoHS and REACH compliant

The 166JB12 is a low voltage/filament power transformer from the 166 Series of economical single-primary, open style chassis mount transformers. It takes a 117V 50/60 Hz. primary and delivers a 12 V secondary rated 1.2 A RMS, for a power rating of 14.4 VA. It suits OEM engineers, equipment builders and technicians who need a compact line-to-low-voltage transformer that bolts directly to a chassis. Compared with the 166K12, which shares its 14.4 VA / 12 V / 1.2 A figures, the 166JB12 has a 117V 50/60 Hz. primary and a secondary listed without a center tap, and its B dimension is 1.75 in rather than 1.63 in.

Construction is open style with a channel bracket and two-hole chassis mounting. A dual bobbin design means no electrostatic shield is required, and the series uses Class B insulation (130 °C) for extra protection, while the design is UL listed as Class A (105 °C). Leads are a minimum of 6 in long. The drawing schematic shows black primary leads and green secondary leads.

Overall dimensions from the series table are A 3.25 in (83 mm), B 1.75 in (44 mm) and C 2.00 in (51 mm), with a D (hole-to-hole mounting) dimension of 2.81 in (71 mm); the mounting dimension column lists 0.19 in (5 mm) (mounting ref. C). The part drawing gives A 3.25 in / 82.6 mm, B 1.75 in / 44.5 mm, C 2 in / 50.8 mm, D 2.81 in / 71.4 mm and a width-wise mounting hole size of 0.187 in / 4.7 mm. Shipping weight is 1 lbs (0.45 kg).

The 166 Series is hi-pot tested at 2,000V RMS, UL listed and CSA certified, and this part is listed as RoHS and REACH compliant.

Ideal For

  • Low voltage and filament supplies from a 117V 50/60 Hz. line
  • Chassis-mounted power supplies needing 12 V at up to 1.2 A
  • Equipment requiring a 12 VAC secondary without a center tap
  • OEM equipment and control panels requiring a 14.4 VA transformer

Mounting

Mounting StyleOpen style, channel bracket, two-hole chassis mount
Mounting ReferenceC
Mounting Hole Size (Width-wise)0.187 in / 4.7 mm
Mounting Dimension (Series Table)0.19 in (5 mm)

Overview

StyleOpen Style, Chassis Mount
Series166 Series - Low Voltage/Filament - Economical Single Primary
Part Number166JB12
Product TypePower transformer, low voltage
Long DescriptionPower transformer, low voltage, 117V 50/60 Hz., 14.4VA, 12, 1.2A
Short DescriptionPOWER TX 117VAC 12VCT@1.2A

Dimensions

Overall Dimension A3.25 in (83 mm)
Overall Dimension B1.75 in (44 mm)
Overall Dimension C2.00 in (51 mm)
Dimension A (Drawing)3.25 in / 82.6 mm
Dimension B (Drawing)1.75 in / 44.5 mm
Dimension C (Drawing)2 in / 50.8 mm
Hole-to-Hole Mounting (D)2.81 in (71 mm)
Hole-to-Hole Mounting D (Drawing)2.81 in / 71.4 mm

Electrical

InsulationClass B (130 °C); UL listed as a Class A (105 °C) design
Power Rating14.4 VA
Primary Voltage117V 50/60 Hz.
Electrostatic ShieldNot required (dual bobbin design)
Secondary Current (RMS)1.2 A
Secondary Voltage (RMS)12 VAC
Hi-Pot Test (Series Specification)2,000V RMS

Identifiers

UPC623980024660
UNSPSC39121301

Packaging & Shipping

Shipping Weight1 lbs (0.45 kg)

Construction & Finish

LeadsMinimum 6 in long
BobbinDual bobbin design

Compliance & Certifications

ULUL listed
CSACSA certified
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What input voltage does the 166JB12 require?▾

The 166JB12 has a single primary rated 117V 50/60 Hz..

What is the secondary output of the 166JB12?▾

It provides 12 VAC RMS at 1.2 A, a power rating of 14.4 VA.

How is the 166JB12 mounted and what are its dimensions?▾

It is an open style transformer with a channel bracket for two-hole chassis mounting. Overall dimensions are A 3.25 in (83 mm), B 1.75 in (44 mm), C 2.00 in (51 mm), with 2.81 in (71 mm) between mounting holes (D); the drawing lists a 0.187 in / 4.7 mm width-wise mounting hole.

Is the 166JB12 UL listed and CSA certified?▾

Yes. The 166 Series is UL listed (as a Class A, 105 °C design, while using Class B 130 °C insulation) and CSA certified. The 166JB12 is also listed as RoHS and REACH compliant.

Does the 166JB12 need an electrostatic shield?▾

No. The series uses a dual bobbin design, so no electrostatic shield is required. The series is hi-pot tested at 2,000V RMS.

How long are the leads on the 166JB12?▾

Leads are a minimum of 6 in long. Per the schematic, primary leads are black and secondary leads are green.