(224) 955-1644
Hammond ManufacturingAuthorized partner store
Hammond 166GD12 8.4 VA open style chassis mount power transformer with 12 VAC secondary and channel bracket

Hammond 166GD12 8.4 VA 12V 0.7A 117V 50/60Hz Power Transformer

Hammond Manufacturing|

MPN: 166GD12

|

UPC: 623980024615

In Stock
$10.71

Ships from and sold by A5 IT

Ground Shipping · $16.89Arrives by Monday, Oct 26
Order within 2h 49m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 8.4 VA rating: 12 VAC secondary at 0.7 A (RMS)
  • 117V 50/60 Hz single primary for 50 Hz or 60 Hz supplies
  • Open style channel bracket with two-hole chassis mount, 2.38 in (60 mm) hole-to-hole
  • Compact 2.81 x 1.63 x 1.69 in overall (A x B x C), 0.72 lbs shipping weight
  • Dual bobbin design, no electrostatic shield required; minimum 6 in leads
  • Class B (130 °C) insulation, UL listed as a Class A (105 °C) design
  • Hi-pot tested at 2,000 V RMS; UL listed, CSA certified, RoHS and REACH compliant

The 166GD12 is a low voltage/filament power transformer from the Hammond 166 Series, supplying a 12 VAC secondary rated at 0.7 A for a total of 8.4 VA from a single 117V 50/60 Hz primary. It is intended for designers, OEM engineers and repair technicians who need a compact, open style transformer that bolts straight to a chassis.

Unlike most of the 166 Series, which is wound for 115 VAC at 60 Hz, the 166GD12 is one of the versions rated for a 117 VAC, 50/60 Hz primary, so it can be used on either line frequency. This version has a 12 VAC secondary without a center tap, so the winding is brought out as two leads.

Construction is open style with a channel bracket and two-hole chassis mount, and the transformer uses a dual bobbin design, so no electrostatic shield is required. Leads are a minimum of 6 in long. On the drawing schematic the primary leads are black and the secondary leads green. Insulation is Class B (130 °C) for extra protection, while the design is UL listed as Class A (105 °C).

Overall dimensions are 2.81 in (71 mm) (A), 1.63 in (41 mm) (B) and 1.69 in (43 mm) (C), with 2.38 in (60 mm) between mounting holes (D) and 0.19 in (5 mm) mounting holes. The part drawing gives the same measurements more precisely as 2.81 in / 71.4 mm (A), 1.63 in / 41.4 mm (B) and 1.69 in / 42.9 mm (C), with 2.38 in / 60.5 mm hole-to-hole spacing and 0.187 in / 4.7 mm width-wise mounting holes. Shipping weight is 0.72 lbs (0.33 kg).

The design carries a hi-pot test of 2,000 V RMS, and the series is UL listed and CSA certified. The 166GD12 is also listed as RoHS and REACH compliant.

Ideal For

  • Low voltage 12 VAC supply for chassis-mounted electronic equipment
  • Filament supply transformer at 0.7 A
  • Circuits needing a plain two-lead 12 VAC secondary
  • Equipment operating on 117V 50/60 Hz mains
  • Replacement or OEM power transformer for 8.4 VA loads

Overview

Series166 Series - Economical Single Primary, Open Style Chassis Mount
DescriptionPower transformer, low voltage, 117V 50/60 Hz., 8.4VA, 12, 0.7A
Product TypePower transformer, low voltage/filament
Short DescriptionPOWER TX 117VAC 12VCT@.70A

Dimensions

Mounting Hole Size0.19 in (5 mm); drawing width-wise 0.187 in / 4.7 mm
Mounting ReferenceC
Overall Dimension A2.81 in (71 mm); drawing 2.81 in / 71.4 mm
Overall Dimension B1.63 in (41 mm); drawing 1.63 in / 41.4 mm
Overall Dimension C1.69 in (43 mm); drawing 1.69 in / 42.9 mm
Hole-to-Hole Mounting Dimension (D)2.38 in (60 mm); drawing 2.38 in / 60.5 mm

Electrical

Center TapNo
Hi-Pot Test2,000 V RMS
Power Rating8.4 VA
Primary Voltage117V 50/60 Hz.
Secondary Current (RMS)0.7 A
Secondary Voltage (RMS)12 VAC

Identifiers

UPC623980024615
UNSPSC39121301
Part Number166GD12

Packaging & Shipping

Shipping Weight0.72 lbs (0.33 kg)

Construction & Finish

StyleOpen style, channel bracket
MountingTwo-hole chassis mount
Lead LengthMinimum 6 in
Bobbin DesignDual bobbin - no electrostatic shield required
Insulation ClassClass B (130 °C); UL listed as a Class A (105 °C) design

Compliance & Certifications

ULUL listed
CSACSA certified
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What are the input and output ratings of the 166GD12?▾

The 166GD12 has a 117V 50/60 Hz primary and a 12 VAC secondary rated at 0.7 A RMS, for a power rating of 8.4 VA.

Does the 166GD12 have a center-tapped secondary?▾

No. The secondary is listed as 12 VAC with no C.T. designation, and the drawing schematic shows only two secondary leads. Note that the manufacturer's short description reads "POWER TX 117VAC 12VCT@.70A", but the part attributes and drawing list the secondary as 12 VAC without a center tap.

Can the 166GD12 be used on 50 Hz power?▾

Yes. Its primary is rated 117V 50/60 Hz, so it is specified for both 50 Hz and 60 Hz supplies.

How is the 166GD12 mounted and how big is it?▾

It is an open style transformer with a channel bracket and two-hole chassis mount. Overall dimensions are 2.81 in (71 mm) (A) x 1.63 in (41 mm) (B) x 1.69 in (43 mm) (C), with 2.38 in (60 mm) between the 0.19 in (5 mm) mounting holes.

What safety testing and approvals apply to the 166GD12?▾

It is hi-pot tested at 2,000 V RMS, uses Class B (130 °C) insulation and is UL listed as a Class A (105 °C) design. The series is UL listed and CSA certified, and this part is RoHS and REACH compliant.

How much does the 166GD12 weigh?▾

The shipping weight is 0.72 lbs (0.33 kg).