(224) 955-1644
Hammond ManufacturingAuthorized partner store
Hammond 166G8 open-style chassis-mount power transformer, 8 VAC center-tapped 0.5 A secondary, 4 VA

Hammond 166G8 8V CT 0.5A Low Voltage Power Transformer

Hammond Manufacturing|

MPN: 166G8

|

UPC: 623980223704

In Stock
$16.46

Ships from and sold by A5 IT

Ground Shipping · $16.89Arrives by Monday, Oct 26
Order within 2h 47m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 4 VA rating: 8 VAC center-tapped (C.T.) at 0.5 A secondary (RMS)
  • 115V 60 Hz single primary
  • Open style channel bracket, two-hole chassis mount
  • Class B (130 °C) insulation; UL listed as a Class A (105 °C) design
  • Hi-Pot tested at 2,000 V RMS; UL listed and CSA certified
  • Dual bobbin design - no electrostatic shield required
  • Minimum 6" long leads
  • RoHS and REACH compliant; shipping weight 0.4 lbs (0.18 kg)

The Hammond 166G8 is a 4 VA low-voltage transformer providing 8 VAC center-tapped at 0.5 A from a 115 V 60 Hz supply. Part of the 166 Series of economical single-primary, low-voltage/filament transformers, it is an open-style, chassis-mount design aimed at OEM engineers, electronics designers and repair technicians who need a small, fixed low-voltage AC source inside equipment.

Construction uses a dual bobbin design, so no electrostatic shield is required. Insulation is Class B (130 °C) for extra protection, and the transformer is UL listed as a Class A (105 °C) design. Each unit is Hi-Pot tested at 2,000 V RMS, and the series is UL listed and CSA certified. The 166G8 is also listed as RoHS and REACH compliant.

The series ordering table lists dimensions for the 166G8 of A 2.38 in (60 mm), B 1.38 in (35 mm), C 1.38 in (35 mm) and D 2.00 in (51 mm), with a 0.19 in (5 mm) mounting dimension. Shipping weight is 0.4 lbs (0.18 kg). Mounting is by an open-style channel bracket with two holes for chassis mounting, and the transformer is supplied with minimum 6" long leads.

The primary is rated 115 VAC, 60 Hz. For 117/234 V or 50/60 Hz operation, or for dual secondaries, the manufacturer points to its 266 Series.

Ideal For

  • Low-voltage 8 VAC supply inside 115 V 60 Hz equipment
  • Center-tapped 8 VAC secondary for split low-voltage circuits
  • Filament and low-voltage power in chassis-built electronics
  • OEM chassis-mount power sections up to 4 VA

Mounting

Mounting MethodOpen style, channel bracket, two hole chassis mount
Mounting Dimension0.19 in (5 mm)
Mounting ReferenceC

Overview

StyleOpen style, chassis mount
Series166 Series
DescriptionPower transformer, low voltage, 115V 60 Hz., 4VA, 8 C.T., 0.5A
Part Number166G8
Product TypePower transformer - low voltage/filament
Short DescriptionPOWER TX 115VAC - 8V@.5A

Dimensions

Dimension A2.38 in (60 mm)
Dimension B1.38 in (35 mm)
Dimension C1.38 in (35 mm)
Dimension D2.00 in (51 mm)

Electrical

Hi-Pot Test2,000 V RMS
Power Rating4 VA
Primary TypeEconomical single primary
Primary Voltage115V 60 Hz.
Secondary Current (RMS)0.5 A
Secondary Voltage (RMS)8 C.T. VAC

Identifiers

UPC623980223704
UNSPSC39121301

Packaging & Shipping

Shipping Weight0.4 lbs (0.18 kg)

Construction & Finish

LeadsMinimum 6" long
Bobbin DesignDual bobbin - no electrostatic shield required
Insulation ClassClass B (130 °C)

Compliance & Certifications

ULUL listed (as a Class A, 105 °C design)
CSACSA certified
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What are the output ratings of the 166G8?▾

The 166G8 is rated 4 VA with a secondary of 8 VAC center-tapped (C.T.) at 0.5 A (RMS).

What input voltage does the 166G8 need?▾

It has an economical single primary rated 115 VAC, 60 Hz. For 117/234 V or 50/60 Hz operation, the manufacturer points to its 266 Series.

Is the 166G8 center tapped?▾

Yes. The secondary is listed as 8 C.T. (center tapped).

How is the 166G8 mounted and how big is it?▾

It is an open-style, channel-bracket, two-hole chassis-mount transformer. The series table lists A 2.38 in (60 mm), B 1.38 in (35 mm), C 1.38 in (35 mm) and D 2.00 in (51 mm), with a 0.19 in (5 mm) mounting dimension.

What safety approvals does the 166G8 have?▾

The 166 Series is UL listed (as a Class A, 105 °C design, using Class B 130 °C insulation) and CSA certified, and units are Hi-Pot tested at 2,000 V RMS. The 166G8 is also RoHS and REACH compliant.

How much does the 166G8 weigh?▾

The listed shipping weight is 0.4 lbs (0.18 kg).