Hammond 166F6 1.89VA 6.3V Center-Tapped Transformer, 300mA
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- Secondary rated 6.3 C.T. (RMS VAC) at 0.3 A
- 1.89 VA power rating from a 115 V, 60 Hz single primary
- Open-style channel bracket for two-hole chassis mounting
- Dual bobbin design; no electrostatic shield required
- Class B insulation (130 degrees C); UL listed as a Class A (105 degrees C) design
- Hi-Pot tested at 2,000 V RMS; minimum 6 in long leads
- UL listed and CSA certified; RoHS and REACH compliant
The 166F6 is a 1.89 VA transformer that supplies 6.3 V C.T. at 0.3 A from a 115 V, 60 Hz single primary. With twice the current of the 0.15 A 166E6, it suits 6.3 V filament and indicator circuits that draw a little more.
As a 166 Series part it uses an economical single-primary design, an open-style channel bracket for two-hole chassis mounting, and minimum 6 in long leads. The dual bobbin construction means no electrostatic shield is required. Windings use Class B insulation (130 degrees C) for extra protection, although the design is UL listed as a Class A (105 degrees C) design, and each unit is Hi-Pot tested at 2,000 V RMS.
The ordering table gives the 166F6 an overall size of 2.06 in (52 mm) at A, 1.38 in (35 mm) at B and 1.19 in (30 mm) at C, with dimension D at 1.75 in (44 mm) and a 0.19 in (5 mm) mounting dimension. It ships at 0.3 lbs (0.14 kg).
- Power rating: 1.89 VA
- Primary: 115 V, 60 Hz
- Secondary: 6.3 C.T. (RMS VAC) at 0.3 A
- Shipping weight: 0.3 lbs (0.14 kg)
The 166 Series is UL listed and CSA certified, and the 166F6 is listed as RoHS and REACH compliant. Identifiers include UPC 623980222400 and UNSPSC 39121301.
Ideal For
- 6.3 V C.T. filament and indicator supplies at up to 0.3 A
- Low-voltage filament and indicator supplies
- Small power supplies for 115 V, 60 Hz equipment
- Center-tapped secondary circuits
Mounting
| Mounting Ref | C |
| Mounting Style | Open style, channel bracket, two hole chassis mount |
| Mounting Dimension | 0.19 in (5 mm) |
Overview
| Series | 166 Series - Low Voltage/Filament, Economical Single Primary, Open Style Chassis Mount (0.63 VA to 288 VA) |
| Product Type | Power transformer, low voltage, 115V 60 Hz., 1.89VA, 6.3 C.T., 0.3A |
| Short Description | POWER TX 115VAC - 6.3V@.3A |
Dimensions
| Overall Dimension A | 2.06 in (52 mm) |
| Overall Dimension B | 1.38 in (35 mm) |
| Overall Dimension C | 1.19 in (30 mm) |
| Overall Dimension D | 1.75 in (44 mm) |
Electrical
| Primary | 115V 60 Hz., single primary |
| Insulation | Class B (130 degrees C); UL listed as a Class A (105 degrees C) design |
| Hi-Pot Test | 2,000V RMS |
| Power Rating | 1.89 VA |
| Winding Design | Dual bobbin - no electrostatic shield required |
| Secondary Current (RMS) | 0.3 A |
| Secondary Voltage (RMS VAC | 6.3 C.T. |
Identifiers
| UPC | 623980222400 |
| UNSPSC | 39121301 |
| Part Number | 166F6 |
Packaging & Shipping
| Shipping Weight | 0.3 lbs (0.14 kg) |
Construction & Finish
| Leads | Minimum 6" long leads |
| Style | Open style |
Compliance & Certifications
| UL | UL listed |
| CSA | CSA certified |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
How does the 166F6 compare with the 166E6?▾
Both are 6.3 V C.T.; the 166F6 is rated 0.3 A and 1.89 VA, while the 166E6 is rated 0.15 A and 0.95 VA.
What primary voltage does the 166F6 use?▾
The 166F6 has a single 115 V, 60 Hz primary.
How is the 166F6 mounted?▾
It is an open-style transformer with a channel bracket for two-hole chassis mounting; the ordering table lists dimension D as 1.75 in (44 mm) and a mounting dimension of 0.19 in (5 mm).
What insulation class does the 166F6 use?▾
The 166 Series uses Class B insulation (130 degrees C) for extra protection and is UL listed as a Class A (105 degrees C) design.
Is the 166F6 UL listed and RoHS compliant?▾
Yes. The 166 Series is UL listed and CSA certified, and this part is listed as RoHS and REACH compliant.
Related Products
Save 52%166F50 — Power transformer, low voltage, 115V 60 Hz., 15VA, 50 C.T., 0.3A
Hammond Manufacturing · 166F50
Save 52%166FB24 — Power transformer, low voltage, 117V 50/60 Hz., 9.6VA, 24 C.T., 0.4A
Hammond Manufacturing · 166FB24
Save 52%166F5 — Power transformer, low voltage, 115V 60 Hz., 1.25VA, 5 C.T., 0.25A
Hammond Manufacturing · 166F5
Save 52%166G10 — Power transformer, low voltage, 115V 60 Hz., 5VA, 10 C.T., 0.5A
Hammond Manufacturing · 166G10
Save 52%166F44 — Power transformer, low voltage, 115V 60 Hz., 11VA, 44 C.T., 0.25A
Hammond Manufacturing · 166F44