(224) 955-1644
Hammond ManufacturingAuthorized partner store
Hammond 166F12D open-style chassis-mount power transformer, 12 VAC 0.35 A secondary, 4.2 VA

Hammond 166F12D 12V 0.35A Transformer, 117V 50/60 Hz Primary

Hammond Manufacturing|

MPN: 166F12D

|

UPC: 623980036724

Available on Backorder
$9.19

Ships from and sold by A5 IT

Available on backorder — ships as soon as stock arrives

Ground Shipping · $16.89Ships as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 4.2 VA rating: 12 VAC (not center-tapped) at 0.35 A secondary (RMS)
  • 117V 50/60 Hz single primary
  • Open style channel bracket, two-hole chassis mount
  • Class B (130 °C) insulation; UL listed as a Class A (105 °C) design
  • Hi-Pot tested at 2,000 V RMS; UL listed and CSA certified
  • Dual bobbin design - no electrostatic shield required
  • Minimum 6" long leads
  • RoHS and REACH compliant; shipping weight 0.4 lbs (0.18 kg)

The Hammond 166F12D is a 4.2 VA low-voltage transformer with a 117 V 50/60 Hz primary and a plain (non-center-tapped) 12 VAC secondary rated 0.35 A. Part of the 166 Series of economical single-primary, low-voltage/filament transformers, it is an open-style, chassis-mount design aimed at OEM engineers, electronics designers and repair technicians who need a small, fixed low-voltage AC source inside equipment.

Construction uses a dual bobbin design, so no electrostatic shield is required. Insulation is Class B (130 °C) for extra protection, and the transformer is UL listed as a Class A (105 °C) design. Each unit is Hi-Pot tested at 2,000 V RMS, and the series is UL listed and CSA certified. The 166F12D is also listed as RoHS and REACH compliant.

The 166F12D drawing gives overall dimensions of A 2.38 in / 60.5 mm, B 1.38 in / 35.1 mm and C 1.38 in / 35.1 mm, with a hole-to-hole mounting dimension (D) of 2 in / 50.8 mm and 0.187 in / 4.7 mm mounting holes. Shipping weight is 0.4 lbs (0.18 kg). Mounting is by an open-style channel bracket with two holes for chassis mounting, and the transformer is supplied with minimum 6" long leads.

Unlike the 115 V 60 Hz models that make up most of the 166 Series, this part is rated for a 117V 50/60 Hz primary. The drawing identifies black (BLK) primary leads and green (GRN) secondary leads, with no center-tap lead shown.

Ideal For

  • Low-voltage 12 VAC supply inside 50/60 Hz equipment
  • Single 12 VAC secondary where no center tap is needed
  • Filament and low-voltage power in chassis-built electronics
  • OEM chassis-mount power sections up to 4.2 VA

Mounting

Mounting MethodOpen style, channel bracket, two hole chassis mount
Mounting ReferenceC
Mounting Hole Size (Width-wise)0.187 / 4.7 (in / mm); series table: 0.19 in (5 mm)

Overview

StyleOpen style, chassis mount
Series166 Series
DescriptionPower transformer, low voltage, 117V 50/60 Hz., 4.2VA, 12, 0.35A
Part Number166F12D
Product TypePower transformer - low voltage/filament
Short DescriptionPOWER TX 117VAC - 12V@.35A

Dimensions

Overall Dimension A2.38 in (60 mm); drawing: 2.38 / 60.5 (in / mm)
Overall Dimension B1.38 in (35 mm); drawing: 1.38 / 35.1 (in / mm)
Overall Dimension C1.38 in (35 mm); drawing: 1.38 / 35.1 (in / mm)
Hole-to-Hole Mounting Dimension D2.00 in (51 mm); drawing: 2 / 50.8 (in / mm)

Electrical

Center TapNo
Hi-Pot Test2,000 V RMS
Power Rating4.2 VA
Primary TypeSingle primary
Primary Voltage117V 50/60 Hz.
Secondary Current (RMS)0.35 A
Secondary Voltage (RMS)12 VAC

Identifiers

UPC623980036724
UNSPSC39121301

Packaging & Shipping

Shipping Weight0.4 lbs (0.18 kg)

Construction & Finish

LeadsMinimum 6" long
Bobbin DesignDual bobbin - no electrostatic shield required
Insulation ClassClass B (130 °C)

Compliance & Certifications

ULUL listed (as a Class A, 105 °C design)
CSACSA certified
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What are the output ratings of the 166F12D?▾

The 166F12D is rated 4.2 VA with a secondary of 12 VAC (not center-tapped) at 0.35 A (RMS).

What input voltage does the 166F12D need?▾

It has a single primary rated 117V 50/60 Hz.

Is the 166F12D center tapped?▾

No. The secondary is listed as 12 VAC without a center tap, and the drawing shows only the green (GRN) secondary leads.

How is the 166F12D mounted and how big is it?▾

It is an open-style, channel-bracket, two-hole chassis-mount transformer. Overall dimensions are A 2.38 / 60.5, B 1.38 / 35.1 and C 1.38 / 35.1 (in / mm), with 2 / 50.8 (in / mm) hole-to-hole mounting spacing and 0.187 / 4.7 (in / mm) mounting holes.

What safety approvals does the 166F12D have?▾

The 166 Series is UL listed (as a Class A, 105 °C design, using Class B 130 °C insulation) and CSA certified, and units are Hi-Pot tested at 2,000 V RMS. The 166F12D is also RoHS and REACH compliant.

How much does the 166F12D weigh?▾