Hammond 165S12 126VA 12.6V C.T. 10A Chassis Mount Filament Transformer
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 126VA rating, 12.6 VAC center tapped secondary at 10A (R.M.S.)
- 115 VAC, 60 Hz single primary
- Open style, 4 hole frame chassis mount
- Mounting slots 0.22 in x 0.56 in (6 mm x 14 mm)
- Minimum 6 in long leads or copper tabs with holes
- Dual bobbin design: no electrostatic shield required
- Class B insulation (130 degrees C), hi-pot tested at 2,000V RMS
- UL listed (# E207860) Type 3AH and CSA certified (# LR209651)
The 165S12 is a 126VA low voltage, high current power transformer for chassis mounting, from the 165 series of filament transformers. It runs from a single 115 VAC, 60 Hz primary and delivers 12.6 VAC (R.M.S.) center tapped at 10 amps, making it a fit for equipment builders, panel shops and repair technicians who need a heavy-current low voltage secondary with a center tap.
Construction is an open style, 4 hole frame chassis mount with a dual bobbin design, so no electrostatic shield is required. Connections are made through leads a minimum of 6 in long or copper tabs with holes. Insulation is Class B (130 degrees C) and the series is hi-pot tested at 2,000V RMS.
Per the series dimension table, the 165S12 measures A 3.00 in (76 mm), B 3.25 in (83 mm), C 2.56 in (65 mm), D 2.50 in (64 mm), E 3.25 in (83 mm) and F 4.00 in (102 mm), with 0.22 in x 0.56 in mounting slots. Shipping weight is 5 lbs (2.27 kg).
The series is UL listed (# E207860) Type 3AH and CSA certified (# LR209651), and the 165S12 is listed as RoHS and REACH compliant.
Ideal For
- Low voltage, high current 12.6V center tapped supply
- Filament transformer applications
- Chassis-mounted equipment powered from 115 VAC 60 Hz
- Center tapped secondary for rectifier supplies
Mounting
| Mounting Slot | 0.22 in (6 mm) x 0.56 in (14 mm) |
| Mounting Type | Open style, 4 hole frame chassis mount |
Overview
| Series | 165 Series (Low Voltage, Filament High Current, Chassis Mount - 125 VA to 440 VA) |
| Description | Transformer, low voltage, high current, chassis mount, 126VA, 12.6VCT, 10A |
| Part Number | 165S12 |
| Short Description | FIL RECT 126VA 115 12.6CT |
Dimensions
| Dimension A | 3.00 in (76 mm) |
| Dimension B | 3.25 in (83 mm) |
| Dimension C | 2.56 in (65 mm) |
| Dimension D | 2.50 in (64 mm) |
| Dimension E | 3.25 in (83 mm) |
| Dimension F | 4.00 in (102 mm) |
Electrical
| Primary | 115 VAC - 60 Hz, single primary |
| Center Tap | All secondaries are center tapped (C.T.) |
| Hi-Pot Test | 2,000V RMS |
| Power Rating | 126 VA |
| Electrostatic Shield | Not required (dual bobbin design) |
| Secondary Current (R.M.S.) | 10 A |
| Secondary Voltage (R.M.S.) | 12.6 VAC C.T. |
Identifiers
| UPC | 623980217604 |
| UNSPSC | 39121301 |
Packaging & Shipping
| Shipping Weight | 5 lbs (2.27 kg) |
Construction & Finish
| Bobbin | Dual bobbin design |
| Terminations | Minimum 6" long leads or copper tabs with holes |
| Insulation Class | Class B (130 degrees C) |
Compliance & Certifications
| UL | UL listed (# E207860) Type 3AH |
| CSA | CSA certified (# LR209651) |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What are the output ratings of the 165S12?▾
The 165S12 is rated 126VA with a 12.6 VAC center tapped secondary at 10 amps (R.M.S.).
What primary voltage does it accept?▾
It has a single 115 VAC, 60 Hz primary.
How does it mount?▾
It is an open style, 4 hole frame chassis mount transformer with 0.22 in x 0.56 in (6 mm x 14 mm) mounting slots.
How are connections made?▾
The series uses leads a minimum of 6 in long or copper tabs with holes.
What certifications does it have?▾
The 165 series is UL listed (# E207860) Type 3AH and CSA certified (# LR209651); the 165S12 is also listed as RoHS and REACH compliant.
How much does it weigh?▾
The listed shipping weight is 5 lbs (2.27 kg).
Related Products
Save 52%165P60 — Transformer, low voltage, high current, chassis mount, 300VA, 60.0VCT, 5A
Hammond Manufacturing · 165P60
Save 52%165S18 — Transformer, low voltage, high current, chassis mount, 180VA, 18.0VCT, 10A
Hammond Manufacturing · 165S18
Save 52%165P30 — Transformer, low voltage, high current, chassis mount, 150VA, 30.0VCT, 5A
Hammond Manufacturing · 165P30
Save 52%165S25 — Transformer, low voltage, high current, chassis mount, 250VA, 25.0VCT, 10A
Hammond Manufacturing · 165S25
Save 52%165P25 — Transformer, low voltage, high current, chassis mount, 125VA, 25.0VCT, 5A
Hammond Manufacturing · 165P25