(224) 955-1644
Hammond ManufacturingAuthorized partner store
164J120 36VA low profile PCB mount power transformer, 115V primary, 120V C.T. @ .3A

Hammond 164J120 36VA 120V C.T. Low Profile PCB Power Transformer

Hammond Manufacturing|

MPN: 164J120

|

UPC: 623980260662

In Stock
$13.19

Ships from and sold by A5 IT

Ground Shipping · $16.89Arrives by Monday, Oct 26
Order within 50m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 36VA power rating with 115V single primary, 50/60 Hz
  • Secondary 120V C.T. @ .3A in series or 60V @ .6A in parallel
  • Low profile, split bobbin design for PCB mounting with industry standard pin spacing
  • Four-hole mounting for #6 screws (mounting screws not provided)
  • Non-concentric dual secondaries: low coupling, no electrostatic shield required
  • Class B insulation (130 degrees C), hipot 2,500V RMS
  • c UL us recognized; RoHS and REACH compliant

The 164J120 is a 36VA low voltage power transformer for printed circuit board mounting, built in a low profile, split bobbin format. It has an economical single 115V primary for 50/60 Hz operation and a dual-winding secondary that delivers 120V C.T. @ .3A when the windings are connected in series, or 60V @ .6A when they are connected in parallel. It suits OEM engineers and electronics designers who need a compact board-level AC source at 120V centre-tapped or 60V.

The two secondary windings are non-concentrically wound, which keeps primary-to-secondary coupling low so no electrostatic shield is required. The unit is designed so that all windings must be used. Insulation is Class B (130 degrees C) and the transformer is hipot tested at 2,500V RMS. It is c UL us recognized and listed as RoHS and REACH compliant.

As a 36VA (J-size) model in the 162-164 series, the 164J120 measures 2.63 in long, 2.19 in wide and 1.56 in high on the series mechanical table, with a listed weight of 1.1 lbs and a shipping weight of 0.8 lbs (0.36 kg). It uses industry standard PCB pin spacing and four-hole mounting (mounting screws not provided), sized for #6 screws.

The part drawing shows the 115V primary on pins 1 and 4, with the two secondary windings on pins 5-6 and 7-8, each marked 60V at 300mA. Need universal 115/230V input instead? The equivalent dual-primary part in the same series is 162J120.

Ideal For

  • Board-level low voltage AC supply from a 115V line
  • 120V centre-tapped secondary (series connection)
  • 60V higher-current output (parallel connection)
  • OEM electronics requiring a low profile PCB mount transformer

Mounting

Mounting TypeP.C. board mount, industry standard pin spacing
Mounting HolesFour-hole mounting (mounting screws not provided)
Mounting Screw#6

Overview

Series162-164 Series (Low Voltage PCB Mount - Low Profile - 1.1 VA to 36 VA)
DescriptionTransformer, low voltage PCB mount, low profile, 115V, 36VA, 120V C.T. @ .3A
Part Number164J120
VA Size LetterJ
Short DescriptionPOWER TX 36VA 115V 50/60HZ
Equivalent Dual Primary (115/230V) Part162J120

Dimensions

Width (W)2.19 in
Height (H)1.56 in
Length (L)2.63 in
Dimension A0.40 in
Dimension B0.40 in
Dimension C1.85 in
Dimension N1.75 in
Dimension P2.19 in

Electrical

Hipot2,500V RMS
PrimarySingle primary, 115V
Frequency50/60 Hz
Power Rating36 VA
Primary PinsPin 1 - Pin 4: 115V
Secondary PinsPin 5 - Pin 6: 60V 300mA; Pin 7 - Pin 8: 60V 300mA
Electrostatic ShieldNot required (low primary to secondary coupling)
Secondary (RMS) Series120V C.T. @ .3A
Secondary ConstructionDual winding secondaries, non-concentrically wound; all windings must be used
Secondary (RMS) Parallel60V @ .6A

Identifiers

UPC623980260662
UNSPSC39121301

Packaging & Shipping

Shipping Weight0.8 lbs (0.36 kg)
Weight (Series Table)1.1 lbs

Construction & Finish

ProfileLow profile, split bobbin design
Insulation ClassClass B, 130 degrees C

Compliance & Certifications

RoHS CompliantYes
REACH CompliantYes
Safety Recognitionc UL us recognized

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What output does the 164J120 provide?▾

With the two secondary windings in series it provides 120V C.T. @ .3A (RMS); with them in parallel it provides 60V @ .6A (RMS). The power rating is 36VA.

What input voltage does it need?▾

The 164J120 has a single 115V primary and operates on 50/60 Hz. The dual-primary 115/230V equivalent is 162J120.

How is it mounted?▾

It is a P.C. board mount transformer with industry standard pin spacing and four-hole mounting (mounting screws not provided); the series table lists #6 mounting screws.

How large is it?▾

The series mechanical table lists L 2.63 in, W 2.19 in and H 1.56 in for the 36VA size, with a weight of 1.1 lbs.

Can I use only one secondary winding?▾

No. The series data states that units are designed so that all windings must be used, connected either in series or in parallel.

What approvals does it carry?▾

The series is c UL us recognized, and this part is listed as RoHS and REACH compliant. Insulation is Class B (130 degrees C) with a 2,500V RMS hipot.