Hammond 164G36 12VA 36V Center-Tapped PCB Transformer, 115V Primary
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 12VA rating: 36V C.T. @ .35A with secondaries in series, 18V @ .7A in parallel
- Single 115V primary for 50/60 Hz operation
- Two-hole mounting with #4 screws (not provided) plus industry-standard PCB pin spacing
- Low-profile split bobbin, 1.88 x 1.56 x 1.50 in (L x W x H)
- Dual non-concentric secondaries; low coupling, no electrostatic shield required
- Class B 130 degrees C insulation, 2,500V RMS hipot
- c UL us recognized; RoHS and REACH compliant
The 164G36 is a 12VA low-voltage power transformer designed to mount directly on a printed circuit board. It has a single 115V primary rated for 50/60 Hz operation and a low-profile, split bobbin construction, making it a fit for OEM engineers and board designers who need a 36V centre-tapped secondary in a compact footprint. Connected in series it supplies 36V C.T. at 0.35A; connected in parallel, 18V at 0.7A.
Construction uses dual secondary windings, non-concentrically wound, which gives low primary-to-secondary coupling without the need for an electrostatic shield. The insulation system is Class B, rated 130 degrees C, with a 2,500V RMS hipot. All windings are intended to be used together in either the series or the parallel connection.
On the series specification sheet the G-size body is 1.88 in long, 1.56 in wide and 1.50 in high, weighing 0.7 lb. The 12VA size uses two-hole mounting with #4 screws (mounting screws are not provided) in addition to its industry-standard P.C. board pins.
The 164G36 drawing labels each secondary winding (pins 5-6 and pins 7-8) at 18V, 0.35A, with the 115V primary on pins 1 and 4; pin numbers are embossed on the bobbin flange.
The transformer is c UL us recognized and listed as RoHS and REACH compliant. Where a design must run from 115V or 230V, the dual-primary equivalent in the same series is 162G36.
Ideal For
- Low-voltage AC supply on printed circuit boards
- Board-level designs needing 36V centre-tapped or 18V secondary
- OEM equipment powered from 115V, 50/60 Hz mains
- Low-profile PCB layouts with limited height
Mounting
| Mounting Type | P.C. board mount, industry standard pin spacing |
| Mounting Holes | Two-hole mounting (12 VA size) |
| Mounting Screw | #4 (mounting screws not provided) |
Overview
| Series | 162-164 Series (164 = single primary 115V) |
| Part Number | 164G36 |
| Product Type | Transformer, low voltage PCB mount, low profile |
| Short Description | POWER TX 12VA 115V 50/60HZ |
| Dual Primary (115/230V) Equivalent | 162G36 |
Dimensions
| Size Letter | G |
| Width (W) - Spec Sheet | 1.56" |
| Height (H) - Spec Sheet | 1.50" |
| Length (L) - Spec Sheet | 1.88" |
| Dimension A - Spec Sheet | 0.30" |
| Dimension B - Spec Sheet | 0.40" |
| Dimension C - Spec Sheet | 1.41" |
| Dimension M - Spec Sheet | 1.25" |
Electrical
| Hipot | 2,500V RMS |
| Frequency | 50/60 Hz |
| Primary Voltage | 115V (single primary) |
| Insulation Class | Class B, 130 degrees C |
| Power Rating (VA) | 12 |
| Electrostatic Shield | Not required (low primary to secondary coupling) |
| Secondary (RMS) Series | 36V C.T. @ .35A |
| Secondary Configuration | Dual winding secondaries, non-concentrically wound; all windings must be used |
| Secondary (RMS) Parallel | 18V @ .7A |
Identifiers
| UPC | 623980260440 |
| UNSPSC | 39121301 |
Packaging & Shipping
| Shipping Weight | 0.75 lbs (0.34 kg) |
Construction & Finish
| Design | Low profile, split bobbin |
| Unit Weight - Spec Sheet | 0.7 lbs |
Compliance & Certifications
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| Agency Recognition | c UL us recognized |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What output voltage and current does the 164G36 provide?▾
With the two secondaries connected in series it provides 36V C.T. @ .35A; connected in parallel it provides 18V @ .7A. The transformer is rated 12VA.
Can I use only one of the secondary windings?▾
The series is designed so that all windings must be used, so connect both secondary windings, either in series for the centre-tapped output or in parallel for the lower-voltage, higher-current output.
What input voltage does the 164G36 accept?▾
It has a single 115V primary and operates on 50/60 Hz. For universal 115/230V dual-primary operation, the matching part in the series is 162G36.
How is it mounted?▾
It mounts on a P.C. board with industry-standard pin spacing and uses two-hole mounting with #4 screws. Mounting screws are not provided.
What are the dimensions of the 164G36?▾
The series specification sheet lists the G size at 1.88 in L x 1.56 in W x 1.50 in H, with a weight of 0.7 lb. Shipping weight is 0.75 lbs (0.34 kg).
What insulation and safety ratings does it carry?▾
Class B insulation rated 130 degrees C, a 2,500V RMS hipot, and c UL us recognition. It is also listed as RoHS and REACH compliant.
Related Products
Save 52%164G28 — Transformer, low voltage PCB mount, low profile, 115V, 12VA, 28V C.T. @ .42A
Hammond Manufacturing · 164G28
Save 52%164G48 — Transformer, low voltage PCB mount, low profile, 115V, 12VA, 48V C.T. @ .25A
Hammond Manufacturing · 164G48
Save 52%164G24 — Transformer, low voltage PCB mount, low profile, 115V, 12VA, 24V C.T. @ .5A
Hammond Manufacturing · 164G24
Save 52%164G56 — Transformer, low voltage PCB mount, low profile, 115V, 12VA, 56V C.T. @ .22A
Hammond Manufacturing · 164G56
Save 52%164G20 — Transformer, low voltage PCB mount, low profile, 115V, 12VA, 20V C.T. @ .6A
Hammond Manufacturing · 164G20