164G20 low-profile 12VA PCB mount power transformer, 115V primary, 20V C.T. @ .6A secondary

Hammond 164G20 12VA 20V Center-Tapped PCB Transformer, 115V Primary

Hammond Manufacturing|

MPN: 164G20

|

UPC: 623980260242

In Stock
$7.24

Ships from and sold by A5 IT

Ground Shipping · $16.89Arrives by Monday, Oct 26
Order within 1h 49m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 12VA rating: 20V C.T. @ .6A with secondaries in series, 10V @ 1.2A in parallel
  • Single 115V primary for 50/60 Hz operation
  • Two-hole mounting with #4 screws (not provided) plus industry-standard PCB pin spacing
  • Low-profile split bobbin, 1.88 x 1.56 x 1.50 in (L x W x H)
  • Dual non-concentric secondaries; low coupling, no electrostatic shield required
  • Class B 130 degrees C insulation, 2,500V RMS hipot
  • c UL us recognized; RoHS and REACH compliant

The 164G20 is a 12VA low-voltage power transformer designed to mount directly on a printed circuit board. It has a single 115V primary rated for 50/60 Hz operation and a low-profile, split bobbin construction, making it a fit for OEM engineers and board designers who need a 20V centre-tapped secondary in a compact footprint. Its secondary rating is 20V C.T. at 0.6A in series, or 10V at 1.2A in parallel.

Construction uses dual secondary windings, non-concentrically wound, which gives low primary-to-secondary coupling without the need for an electrostatic shield. The insulation system is Class B, rated 130 degrees C, with a 2,500V RMS hipot. All windings are intended to be used together in either the series or the parallel connection.

On the series specification sheet the G-size body is 1.88 in long, 1.56 in wide and 1.50 in high, weighing 0.7 lb. The 12VA size uses two-hole mounting with #4 screws (mounting screws are not provided) in addition to its industry-standard P.C. board pins.

The transformer is c UL us recognized and listed as RoHS and REACH compliant. Where a design must run from 115V or 230V, the dual-primary equivalent in the same series is 162G20.

Ideal For

  • Low-voltage AC supply on printed circuit boards
  • Board-level designs needing 20V centre-tapped or 10V secondary
  • OEM equipment powered from 115V, 50/60 Hz mains
  • Low-profile PCB layouts with limited height

Mounting

Mounting TypeP.C. board mount, industry standard pin spacing
Mounting HolesTwo-hole mounting (12 VA size)
Mounting Screw#4 (mounting screws not provided)

Overview

Series162-164 Series (164 = single primary 115V)
Part Number164G20
Product TypeTransformer, low voltage PCB mount, low profile
Short DescriptionPOWER TX 12VA 115V 50/60HZ
Dual Primary (115/230V) Equivalent162G20

Dimensions

Size LetterG
Width (W) - Spec Sheet1.56"
Height (H) - Spec Sheet1.50"
Length (L) - Spec Sheet1.88"
Dimension A - Spec Sheet0.30"
Dimension B - Spec Sheet0.40"
Dimension C - Spec Sheet1.41"
Dimension M - Spec Sheet1.25"

Electrical

Hipot2,500V RMS
Frequency50/60 Hz
Primary Voltage115V (single primary)
Insulation ClassClass B, 130 degrees C
Power Rating (VA)12
Electrostatic ShieldNot required (low primary to secondary coupling)
Secondary (RMS) Series20V C.T. @ .6A
Secondary ConfigurationDual winding secondaries, non-concentrically wound; all windings must be used
Secondary (RMS) Parallel10V @ 1.2A

Identifiers

UPC623980260242
UNSPSC39121301

Packaging & Shipping

Shipping Weight0.62 lbs (0.28 kg)

Construction & Finish

DesignLow profile, split bobbin
Unit Weight - Spec Sheet0.7 lbs

Compliance & Certifications

RoHS CompliantYes
REACH CompliantYes
Agency Recognitionc UL us recognized

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What output voltage and current does the 164G20 provide?▾

With the two secondaries connected in series it provides 20V C.T. @ .6A; connected in parallel it provides 10V @ 1.2A. The transformer is rated 12VA.

Can I use only one of the secondary windings?▾

The series is designed so that all windings must be used, so connect both secondary windings, either in series for the centre-tapped output or in parallel for the lower-voltage, higher-current output.

What input voltage does the 164G20 accept?▾

It has a single 115V primary and operates on 50/60 Hz. For universal 115/230V dual-primary operation, the matching part in the series is 162G20.

How is it mounted?▾

It mounts on a P.C. board with industry-standard pin spacing and uses two-hole mounting with #4 screws. Mounting screws are not provided.

What are the dimensions of the 164G20?▾

The series specification sheet lists the G size at 1.88 in L x 1.56 in W x 1.50 in H, with a weight of 0.7 lb. Shipping weight is 0.62 lbs (0.28 kg).

What insulation and safety ratings does it carry?▾

Class B insulation rated 130 degrees C, a 2,500V RMS hipot, and c UL us recognition. It is also listed as RoHS and REACH compliant.