
Hammond 164F36 6VA 36V Center-Tapped PCB Transformer, 115V Primary
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 6VA rating: 36V C.T. @ .17A with secondaries in series, 18V @ .34A in parallel
- Single 115V primary for 50/60 Hz operation
- Two-hole mounting with #4 screws (not provided) plus industry-standard PCB pin spacing
- Low-profile split bobbin, 1.63 x 1.31 x 1.31 in (L x W x H)
- Dual non-concentric secondaries; low coupling, no electrostatic shield required
- Class B 130 degrees C insulation, 2,500V RMS hipot
- c UL us recognized; RoHS and REACH compliant
Designed for printed circuit boards, the 164F36 is a low-profile 6VA power transformer with an economical single 115V primary that operates on 50 or 60 Hz. Engineers specifying low-voltage AC for board-level circuits get a 36V centre-tapped secondary from a split bobbin design. Connected in series it supplies 36V C.T. at 0.17A; connected in parallel, 18V at 0.34A.
The secondary is made up of two windings that are wound non-concentrically on the split bobbin. That arrangement keeps primary-to-secondary coupling low, so no electrostatic shield is required. Insulation is Class B (130 degrees C) and the unit is hipot rated at 2,500V RMS. Note that the design requires all windings to be used, so connect both secondaries in series or in parallel.
On the series specification sheet the F-size body is 1.63 in long, 1.31 in wide and 1.31 in high, weighing 0.44 lb. The 6VA size uses two-hole mounting with #4 screws (mounting screws are not provided) in addition to its industry-standard P.C. board pins.
The transformer is c UL us recognized and listed as RoHS and REACH compliant. Where a design must run from 115V or 230V, the dual-primary equivalent in the same series is 162F36.
Ideal For
- Low-voltage AC supply on printed circuit boards
- Board-level designs needing 36V centre-tapped or 18V secondary
- OEM equipment powered from 115V, 50/60 Hz mains
- Low-profile PCB layouts with limited height
Mounting
| Mounting Type | P.C. board mount, industry standard pin spacing |
| Mounting Holes | Two-hole mounting (6 VA size) |
| Mounting Screw | #4 (mounting screws not provided) |
Overview
| Series | 162-164 Series (164 = single primary 115V) |
| Part Number | 164F36 |
| Product Type | Transformer, low voltage PCB mount, low profile |
| Short Description | POWER TX 6VA 115V 50/60HZ |
| Dual Primary (115/230V) Equivalent | 162F36 |
Dimensions
| Size Letter | F |
| Width (W) - Spec Sheet | 1.31" |
| Height (H) - Spec Sheet | 1.31" |
| Length (L) - Spec Sheet | 1.63" |
| Dimension A - Spec Sheet | 0.25" |
| Dimension B - Spec Sheet | 0.35" |
| Dimension C - Spec Sheet | 1.28" |
| Dimension M - Spec Sheet | 1.06" |
Electrical
| Hipot | 2,500V RMS |
| Frequency | 50/60 Hz |
| Primary Voltage | 115V (single primary) |
| Insulation Class | Class B, 130 degrees C |
| Power Rating (VA) | 6 |
| Electrostatic Shield | Not required (low primary to secondary coupling) |
| Secondary (RMS) Series | 36V C.T. @ .17A |
| Secondary Configuration | Dual winding secondaries, non-concentrically wound; all windings must be used |
| Secondary (RMS) Parallel | 18V @ .34A |
Identifiers
| UPC | 623980260433 |
| UNSPSC | 39121301 |
Packaging & Shipping
| Shipping Weight | 0.4 lbs (0.18 kg) |
Construction & Finish
| Design | Low profile, split bobbin |
| Unit Weight - Spec Sheet | 0.44 lbs |
Compliance & Certifications
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| Agency Recognition | c UL us recognized |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What output voltage and current does the 164F36 provide?▾
With the two secondaries connected in series it provides 36V C.T. @ .17A; connected in parallel it provides 18V @ .34A. The transformer is rated 6VA.
Can I use only one of the secondary windings?▾
The series is designed so that all windings must be used, so connect both secondary windings, either in series for the centre-tapped output or in parallel for the lower-voltage, higher-current output.
What input voltage does the 164F36 accept?▾
It has a single 115V primary and operates on 50/60 Hz. For universal 115/230V dual-primary operation, the matching part in the series is 162F36.
How is it mounted?▾
It mounts on a P.C. board with industry-standard pin spacing and uses two-hole mounting with #4 screws. Mounting screws are not provided.
What are the dimensions of the 164F36?▾
The series specification sheet lists the F size at 1.63 in L x 1.31 in W x 1.31 in H, with a weight of 0.44 lb. Shipping weight is 0.4 lbs (0.18 kg).
What insulation and safety ratings does it carry?▾
Class B insulation rated 130 degrees C, a 2,500V RMS hipot, and c UL us recognition. It is also listed as RoHS and REACH compliant.
Related Products
Save 52%164F28 — Transformer, low voltage PCB mount, low profile, 115V, 6VA, 28V C.T. @ .2A
Hammond Manufacturing · 164F28
Save 52%164F48 — Transformer, low voltage PCB mount, low profile, 115V, 6VA, 48V C.T. @ .125A
Hammond Manufacturing · 164F48
Save 52%164F24 — Transformer, low voltage PCB mount, low profile, 115V, 6VA, 24V C.T. @ .25A
Hammond Manufacturing · 164F24
Save 52%164F56 — Transformer, low voltage PCB mount, low profile, 115V, 6VA, 56V C.T. @ .11A
Hammond Manufacturing · 164F56
Save 52%164F20 — Transformer, low voltage PCB mount, low profile, 115V, 6VA, 20V C.T. @ .3A
Hammond Manufacturing · 164F20
