Hammond 162F24 6VA 24V Center-Tapped PCB Transformer, 115/230V
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 6 VA rating with 24V C.T. @ .25A series or 12V @ .5A parallel secondary (RMS)
- Universal dual primary for 115V or 230V input, 50/60 Hz operation
- Low profile: 1.625" L x 1.313" W x 1.290" H per drawing
- Two-hole mounting with #4 screws (not provided) plus PCB pins on industry standard spacing
- Class B insulation (130 degrees C) and 2,500V RMS hipot rating
- Split bobbin with non-concentric dual secondaries; no electrostatic shield required
- cULus recognized; RoHS and REACH compliant
The 162F24 is a low-profile, PC board mount power transformer from the 162-164 Series, rated at 6 VA with a universal dual primary for 115V or 230V operation at 50/60 Hz. It is intended for designers and OEM engineers who need a low-voltage AC source mounted directly on a printed circuit board. The 24V center-tapped series connection delivers .25A, and wiring the two secondaries in parallel gives 12V at .5A.
Construction uses a low profile, split bobbin design with dual winding secondaries that are non-concentrically wound. Primary to secondary coupling is low, so no electrostatic shield is required. Insulation is Class B (130 degrees C) and the unit is hipot rated at 2,500V RMS; the drawing lists a primary-to-secondary hipot test of 2500V, 60Hz for 1 second. Pin numbers are embossed on the bobbin flange. The units are designed so that all windings must be used.
Per the part drawing, the 162F24 measures 1.625" long, 1.313" wide and 1.290" high (inches, ±0.030"), with a series table nominal size of 1.63 x 1.31 x 1.31 in. The series table lists a weight of 0.44 lbs, and the listed shipping weight is 0.39 lbs (0.18 kg). At the 6 VA size the transformer uses two-hole mounting with #4 mounting screws (screws are not provided), in addition to PC board pins on industry standard pin spacing.
Electrically, the drawing shows two 115V primary windings (pins 1-2 and 3-4) and two 12V secondary windings (pins 5-6 and 7-8) marked 250mA each. Test criteria include a maximum excitation current of 45.6mA at 115V, 60Hz, and a secondary no-load voltage of 14.49V ±2% per winding. The part is cULus recognized and is listed as RoHS and REACH compliant. A single-primary 115V version of the same rating is available as the 164F24.
Ideal For
- Low-voltage 24V center-tapped AC supply on printed circuit boards
- 12V parallel-connected secondary supply at .5A
- PCB-mounted power for equipment running on 115V or 230V, 50/60 Hz
- Designs needing low primary-to-secondary coupling without an electrostatic shield
Mounting
| Mounting | PC board mount; two hole mounting (6, 12 and 20VA sizes) |
| Pin Spacing | Industry standard |
| Mounting Screw | #4 (mounting screws not provided) |
| Pin Identification | Pin numbers embossed on bobbin flange |
Overview
| Series | 162-164 Series (162 = dual primary 115/230V) |
| Description | Transformer, low voltage PCB mount, low profile, 115/230V, 6VA, 24V C.T. @ .25A |
| Product Type | Transformer, low voltage PCB mount, low profile |
| Short Description | POWER TX 6VA 115/230 |
| Single-Primary 115V Equivalent | 164F24 |
Dimensions
| Width (Drawing, W) | 1.313" ±0.030 |
| Drawing Dimension A | 0.250" ±0.030 |
| Drawing Dimension B | 0.350" ±0.030 |
| Drawing Dimension C | 1.280" ±0.030 |
| Drawing Dimension D | 0.041" x 0.018" ±0.005 |
| Drawing Dimension E | 0.790" ±0.030 |
| Drawing Dimension F | 0.040" ±0.005 |
| Drawing Dimension G | 0.234" ±0.005 |
| Drawing Dimension J | 0.290" ±0.030 |
| Drawing Dimension K | 0.650" ±0.030 |
| Drawing Dimension M | 0.350" ±0.030 |
| Drawing Dimension N | 1.100" ±0.030 |
| Drawing Dimension P | 0.125" ±0.015 |
| Drawing Dimension Q | 1.063" ±0.030 |
| Drawing Dimension R | 0.125" ±0.015 |
| Height (Drawing, H) | 1.290" ±0.030 |
| Length (Drawing, L) | 1.625" ±0.030 |
| Series Table Dimension A | 0.25 in |
| Series Table Dimension B | 0.35 in |
| Series Table Dimension C | 1.28 in |
| Series Table Dimension M | 1.06 in |
| Nominal Size (Series Table, L X W X H) | 1.63 x 1.31 x 1.31 in |
Electrical
| Frequency | 50/60 Hz |
| Hipot Test | Primary - secondary 2500V, 60Hz, 1 sec |
| Winding Use | All windings must be used |
| Hipot Rating | 2,500V RMS |
| Power Rating | 6 VA |
| Primary Voltage | 115/230V (universal dual primary) |
| Insulation Class | Class B, 130 degrees C |
| Electrostatic Shield | Not required (low primary to secondary coupling) |
| Secondary (RMS) Series | 24V C.T. @ .25A |
| Excitation Current (Iex) | 45.6mA max @ 115V, 60Hz, pin 1 - pin 2 |
| Rating Marked On Drawing | 50/60Hz, 6VA |
| Secondary (RMS) Parallel | 12V @ .5A |
| DC Resistance @ 20°C, Pins 1-2 | 257.9 Ω ±20% |
| DC Resistance @ 20°C, Pins 3-4 | 257.9 Ω ±20% |
| DC Resistance @ 20°C, Pins 5-6 | 4.108 Ω ±20% |
| DC Resistance @ 20°C, Pins 7-8 | 4.108 Ω ±20% |
Identifiers
| UPC | 623980260969 |
| UNSPSC | 39121301 |
| Part Number | 162F24 |
Packaging & Shipping
| Shipping Weight | 0.39 lbs (0.18 kg) |
| Weight (Series Table) | 0.44 lbs |
Construction & Finish
| Design | Low profile, split bobbin |
| Secondaries | Dual winding secondaries, non-concentrically wound |
Compliance & Certifications
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| Safety Recognition | c UL us recognized |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What output voltages does the 162F24 provide?▾
Connected in series the secondaries give 24V C.T. @ .25A (RMS); connected in parallel they give 12V @ .5A. Each of the two secondary windings is marked 12V 250mA on the drawing.
Can the 162F24 run on both 115V and 230V?▾
Yes. The 162 series uses a universal dual primary for 115/230V, with two 115V primary windings on pins 1-2 and 3-4, and operates on 50/60 Hz. The single-primary 115V version is the 164F24.
Does it need mounting hardware?▾
It is a PC board mount part with two-hole mounting at the 6 VA size; #4 mounting screws are used and are not provided.
How large is the 162F24?▾
The drawing gives 1.625" long x 1.313" wide x 1.290" high (±0.030"). The series table lists a nominal 1.63 x 1.31 x 1.31 in and a weight of 0.44 lbs.
What insulation and safety ratings does it carry?▾
Class B insulation (130 degrees C), a 2,500V RMS hipot rating (tested primary to secondary at 2500V, 60Hz for 1 second), and c UL us recognition. It is listed as RoHS and REACH compliant.
Can I leave one secondary winding unused?▾
No. The series specification states the units are designed so that all windings must be used, so connect both secondaries in series or in parallel.
Related Products
Save 52%162F20 — Transformer, low voltage PCB mount, low profile, 115/230V, 6VA, 20V C.T. @ .3A
Hammond Manufacturing · 162F20
Save 52%162F28 — Transformer, low voltage PCB mount, low profile, 115/230V, 6VA, 28V C.T. @ .2A
Hammond Manufacturing · 162F28
Save 52%162F16 — Transformer, low voltage PCB mount, low profile, 115/230V, 6VA, 16V C.T. @ .4A
Hammond Manufacturing · 162F16
Save 52%162F36 — Transformer, low voltage PCB mount, low profile, 115/230V, 6VA, 36V C.T. @ .17A
Hammond Manufacturing · 162F36
Save 52%162F120 — Transformer, low voltage PCB mount, low profile, 115/230V, 6VA, 120V C.T. @ .05A
Hammond Manufacturing · 162F120