Hammond 161G24 10VA 24V Center-Tapped PCB Power Transformer
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 10 VA power rating with a single 115V, 60 Hz primary
- Secondary: 24V C.T. @ 450mA in series, 12V @ 900mA in parallel
- Vertical mount, split bobbin design for PC board mounting
- Non-concentric wound; low primary-to-secondary coupling, no electrostatic shield required
- Class B insulation (130 degrees C); Hipot 2,000V RMS
- CSA certified (File # LR3902) and UL recognized (File #E207860)
- RoHS and REACH compliant
- Dual primary 115/230V equivalent: 160G24
The 161G24 is a 10 VA low voltage power transformer for printed circuit board mounting, built with a single 115V primary rated for 60 Hz only. Its secondary delivers 24V centre-tapped at 450mA when the windings are used in series, or 12V at 900mA when they are connected in parallel. It suits OEM engineers and designers who need a board-level 24V C.T. or 12V AC source from a 115V line.
Construction follows the 160-161 Series design: a vertical mount, split bobbin transformer; the 10 VA size is non-concentric wound. Low primary-to-secondary coupling means no electrostatic shield is required. Insulation is Class B (130 degrees C) with a Hipot rating of 2,000V RMS.
In the series mechanical table for the 10 VA size (161 Series), overall dimensions are A 1.94 in, B 1.44 in and C 1.69 in, with D (pin) 0.02 x 0.04 in, E 1.30 in, G 0.40 in, F 0.03 x 0.19 in, H 1.89 in and J 0.55 in. The shipping weight of this part is 0.7 lbs (0.32 kg).
The 161G24 is CSA certified (File # LR3902) and UL recognized (File #E207860), and it is listed as RoHS and REACH compliant. If the design must also run from 230V or 50 Hz supplies, the dual primary 115/230V counterpart in the ordering table is 160G24.
Ideal For
- PC board mounted 24V center-tapped low voltage supply
- 12V AC source from a 115V, 60 Hz line (parallel connection)
- OEM electronic equipment requiring a UL recognized, CSA certified board transformer
Overview
| Series | 160-161 Series (161 = single primary 115V) |
| Mounting | P.C. board mount, vertical |
| Product Type | Transformer, low voltage PCB mount |
| Short Description | POWER TX 10VA 115V |
| Dual Primary (115/230V) Equivalent | 160G24 |
Dimensions
| A | 1.94 in |
| B | 1.44 in |
| C | 1.69 in |
| E | 1.30 in |
| G | 0.40 in |
| H | 1.89 in |
| J | 0.55 in |
| D Width | 0.04 in |
| F Width | 0.19 in |
| D Thickness | 0.02 in |
| F Thickness | 0.03 in |
Electrical
| Frequency | 60 Hz only |
| Primary Voltage | 115V (single primary) |
| Power Rating (VA) | 10 |
| Secondary (RMS) Series | 24V C.T. @ 450ma |
| Secondary (RMS) Parallel | 12V @ 900ma |
| Hipot (Series Specification) | 2,000V RMS |
Identifiers
| UPC | 623980212500 |
| UNSPSC | 39121301 |
| Part Number | 161G24 |
Packaging & Shipping
| Shipping Weight | 0.7 lbs (0.32 kg) |
Construction & Finish
| Bobbin | Split bobbin, vertical mount |
| Winding | Non-concentric wound |
| Shielding | Low primary to secondary coupling - no electrostatic shield required |
| Insulation Class | Class B - 130 degrees C |
Compliance & Certifications
| UL | Recognized, File #E207860 |
| CSA | Certified, File # LR3902 |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What output does the 161G24 provide?▾
The secondary is rated 24V C.T. @ 450ma with the windings in series, or 12V @ 900ma with them in parallel (RMS values).
Can the 161G24 run on 230V or 50 Hz?▾
No. The 161G24 has a single 115V primary rated for 60 Hz only. The dual primary 115/230V, 50/60 Hz version listed in the ordering table is 160G24.
Does it need an electrostatic shield?▾
No. The series uses low primary to secondary coupling, so no electrostatic shield is required.
What certifications does it carry?▾
It is CSA certified (File # LR3902) and UL recognized (File #E207860), and is listed as RoHS and REACH compliant.
How big is the 161G24?▾
The series table for the 10 VA 161 size lists A 1.94 in, B 1.44 in and C 1.69 in; shipping weight is 0.7 lbs (0.32 kg).
What insulation class is it?▾
Class B insulation, rated 130 degrees C, with a Hipot of 2,000V RMS.
Related Products
Save 52%161G20 — Transformer, low voltage PCB mount, 115V primary, 10VA, 20V C.T. @ 500ma sec
Hammond Manufacturing · 161G20
Save 52%161G28 — Transformer, low voltage PCB mount, 115V primary, 10VA, 28V C.T. @ 360ma sec
Hammond Manufacturing · 161G28
Save 52%161G16 — Transformer, low voltage PCB mount, 115V primary, 10VA, 16V C.T. @ 640ma sec
Hammond Manufacturing · 161G16
Save 52%161G34 — Transformer, low voltage PCB mount, 115V primary, 10VA, 34V C.T. @ 300ma sec
Hammond Manufacturing · 161G34
Save 52%161G120 — Transformer, low voltage PCB mount, 115V primary, 10VA, 120V C.T. @ 85ma sec
Hammond Manufacturing · 161G120