1182T117P 1500 VA toroid power transformer with potted center and flexible leads, 117V @ 12.8A secondary

Hammond 1182T117P 1500 VA Potted Toroid, 234V CT or 117V Output

Hammond Manufacturing|

MPN: 1182T117P

|

UPC: 623980270043

In Stock
$220.56

Ships from and sold by A5 IT

Ground Shipping · $38.99Arrives by Monday, Oct 26
Order within 3h 36m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • Two 117 V secondaries: 234V C.T. @ 6.4A or 117V @ 12.8A
  • 2.10% voltage regulation at 1500 VA
  • Potted toroid center for extra strength at 1,500 VA
  • #12 TEW primary and secondary leads
  • Dual 117/234 VAC, 50/60 Hz primary (parallel for 117 V, series for 234 V)
  • Class B (130 degree C) materials; 4,000 VAC RMS hi-pot primary to secondary
  • UL recognized (file #E207860) and CSA certified (file #209651)
  • Toroid core: low profile, lightweight, cool running, low stray flux (low EMI)

The 1182T117P is a 1500 VA potted-center toroidal transformer with two 117 V secondaries that mirror its two 117 V primaries. Series-connected secondaries give 234V C.T. @ 6.4A and parallel-connected give 117V @ 12.8A, making it the largest 117 V output model in the 1182 range for 117/234 V conversion and isolation.

The drawing lists each secondary as 117V @ 6.40 A, with #12 TEW primary and secondary leads 8"-9" long and stripped 0.5" minimum. The series table gives 2.10% regulation, a potted toroid center and dimension reference M; the series notes that the 1,500 VA size is supplied with a potted center for extra strength. Shipping weight is 28 lbs (12.70 kg), and the drawing lists 24.75 lbs +/- 4%.

On compliance, the 1182 family carries UL recognition to UL 5085-1 and UL 5085-2 under file #E207860 and CSA certification to C22.2 #66.1-6 and #66.2-6 under file #209651, and is self-declared as evaluated to applicable sections of IEC/EN61558-1 and IEC/EN61558-2-4. Windings use Class B (130 degree C) materials, primary-to-secondary insulation is hi-pot tested at 4,000 VAC RMS, and the part is listed as RoHS and REACH compliant.

The dual primary accepts 117 VAC (parallel connection) or 234 VAC (series connection) at 50/60 Hz, with a connection sheet included. Units are designed to run with every winding engaged, in series or parallel, or as an autotransformer. Plan the supply protection for toroidal inrush: the magnetizing current at energization is limited only by the primary's low DC resistance, so a slow-blow fuse, time-delayed breaker or soft-start is recommended.

Ideal For

  • 117 V / 234 V conversion at 1500 VA
  • 1:1 isolation for 117 V equipment
  • Equipment for both 117 VAC and 234 VAC supplies (global use)
  • Designs needing low stray magnetic flux (low EMI) in a low-profile package

Overview

Series1182 Series - Toroid Power Transformers, 15 VA to 1500 VA
ReplacesOlder 182 Toroid Series
DescriptionPower transformer, toroid, 1500 VA, with 117V @ 12.8A secondary, 1182 Series
Part Number1182T117P
Power Rating1500 VA
Product TypePower transformer, toroid
Toroid CenterPotted
Secondary TypeDual
Short DescriptionTOROID,1500VA,50/60HZ,117/117V
Dimension ReferenceM

Electrical

PolarityAdditive (BLK, BRN, RED and GRY)
Frequency50/60 Hz
Primary VoltageDual 117/234 VAC
Primary Connection117 VAC: parallel connection; 234 VAC: series connection
Voltage Regulation2.10%
Winding ConnectionAll windings engaged (series or parallel connected) or connected as an autotransformer
Inrush Current NoteConsider a slow-blow fuse, time delayed circuit breaker or soft start circuitry on the supply line
Secondary (RMS) - Series234V C.T. @ 6.4A
Primary Windings (Drawing)2x 117V BLK-WHT, BRN-ORN
Secondary (RMS) - Parallel117V @ 12.8A
Secondary Windings (Drawing)2x 117V @ 6.40A RED-BLU, GRY-YEL
Hi-Pot Test, Primary - Primary600V, 60Hz, 1 sec
Secondary No-Load Voltage Test@ 117V, 60Hz: BLK & BRN to WHT & ORN; or @ 234V, 50Hz: BLK to ORN (connect BRN & WHT)
Hi-Pot Test, Primary - Secondary4000V, 60Hz, 1 sec
Hi-Pot Test, Secondary - Secondary600V, 60Hz, 1 sec
Voltage Regulation (Part Page, Rounded)2%
Hi-Pot Test, Primary - Secondary (Series Spec)4,000 VAC RMS

Identifiers

UPC623980270043
UNSPSC39121301

Leads & Wiring

Lead LengthMinimum 8" long flexible leads
Connection SheetIncluded with transformer
Primary Lead Wire#12 TEW
Secondary Lead Wire#12 TEW
Primary Lead ColoursBLK-WHT (Primary #1), BRN-ORN (Primary #2)
Secondary Lead ColoursRED-BLU (Secondary #1), GRY-YEL (Secondary #2)
Lead Length & Strip (Drawing)All leads out 8"-9" and stripped 0.5" min.

Packaging & Shipping

Shipping Weight28 lbs (12.70 kg)
Weight (Drawing)24.75 lbs +/- 4%
Country Of OriginCanada

Construction & Finish

CoreToroidal
Potted Center1,500 VA size supplied with a potted center for extra strength
Toroid BenefitsLow profile, lightweight, cool running / high efficiency, low stray magnetic flux leakage (low EMI)
Insulation ClassClass B (130 degree C) materials

Compliance & Certifications

ULUL recognized to UL 5085-1 and UL 5085-2, UL file #E207860
CSACSA certified to C22.2 #66.1-6 and C22.2 #66.2-6, CSA file #209651
IEC/ENSelf-declared evaluated to applicable sections of IEC/EN61558-1 (Second Edition 2005-09) and IEC/EN61558-2-4
RoHS CompliantYes
REACH CompliantYes
CE (2014 Spec Sheet)CE compliant to IEC 61558-2-4
UL (2014 Spec Sheet)UL recognized to UL506 (XPTQ.Guide), UL file #E207860

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

Can the 1182T117P convert between 117 V and 234 V?▾

Yes. Its primaries accept 117 VAC (parallel) or 234 VAC (series), and its secondaries deliver 117V @ 12.8A in parallel or 234V C.T. @ 6.4A in series.

What is the 1182T117P shipping weight?▾

28 lbs (12.70 kg); the drawing lists 24.75 lbs +/- 4%.

Why might the 1182T117P trip a breaker when switched on?▾

Toroidal transformers can draw high magnetizing current when first energized, limited only by the primary's low DC resistance; the overload rarely lasts longer than half a cycle. A slow-blow fuse, time-delayed circuit breaker or soft-start circuitry is recommended on the supply line.

Is it UL and CSA approved?▾

The 1182 series is UL recognized to UL 5085-1 and UL 5085-2 (file #E207860) and CSA certified to C22.2 #66.1-6 and C22.2 #66.2-6 (file #209651).

How do I wire the primary for 117 V or 234 V?▾

Connect the two 117 V primaries (BLK-WHT and BRN-ORN) in parallel for 117 VAC or in series for 234 VAC, 50/60 Hz. A connection sheet is included with the transformer.