Two Door Selection Guide

ABB Controls Disconnect Switches (Flange Mounted Operators)

¹ "M" dimension does not allow for auxiliary switches. Refer to Allen Bradley instructions if additional space is required.

Allen Bradley 1494D Operators (Circuit Breakers)

1 "M" dimension does not allow for auxiliary switches. Refer to Allen Bradley instructions if additional space is required. "K" = 5.88 when "A" = 60.13 "K" = 11.88 when "A" = 72.13 (except 200A switches) "K" = 10.56 when "A" = 72.13 (200A switches only).

Allen Bradley 1494U Operators (Disconnect Switches)

1 Series B 2 "M" dimension does not allow for auxiliary switches

Allen Bradley 1494U Operators (Circuit Breakers)

1 "M" dimension does not allow for auxiliary switches. Refer to Allen Bradley instructions if additional space is required. "K" = 7.88 when "A" = 60.13 "K" = 13.88 when "A" = 72.13

Cutler Hammer Cutler Hammer C361 Disconnect Switches

Part numbers for Complete Operator Mechanisms include flange mounted handle, flexible shaft and circuit breaker mechanism. The last digit of the part number denotes the shaft length (F1S03=3' length). F,J,K frame Flex-Shafts™ available in 3' to 10' lengths. L,N,R frame Flex-Shafts™ available in 4' to 6' lengths.

Space Occupied By Disconnect 1. Flex-Shaft™ System permits circuit breaker locations separate from flange mounted handle mechanism. 2. See National Electrical Code 2005 article 430-10(b) for wiring space (Ref "P") needed for line side conductors. 3. Select shaft length based on location of circuit breaker in the enclosure. Maintain a 4" minimum bending radius for the Flex-Shaft™. 4. Space occupied by circuit breaker is calculated by:

Charts reference Space Occupied by Disconnect Drawing

Space Occupied By Disconnect 1. GE Spectra-Flex™ Operating Cables permit circuit breaker locations separate from flange mounted handle mechanism. 2. See National Electrical Code 2005 article 430-10(b) for wiring space (Ref "P") needed for line side conductors. 3. Select shaft length based on location of circuit breaker in the enclosure. Maintain a 3" minimum bending radius for the Flex-Shaft™. 4. Space occupied by circuit breaker is calculated by: Overall (Height "X" and Width "Y") Minimum wire bend space (manufacturer specified) Location "M" from right to left.

"K" = 7.88 when "A" = 60.13 "K" = 13.88 when "A" = 72.13

Charts reference Space Occupied by Disconnect Drawing.

Circuit Breaker Size includes required base mounting block. Last three digits of operator mechanism part number denote cable length in inches. 24" deep enclosures require longer operating cables. Sold separately. "K" = 7.88 when "A" = 60.13 "K" = 13.88 when "A" = 72.13 (Deduct 1.45 inches from "K" for FHONO48 Operator mechanism for MD,ND,PD,RD Circuit Breakers)

Space Occupied By Disconnect 1. Siemens I-T-E Max-Flex™ System permits circuit breaker locations separate from flange mounted handle mechanism. 2. See National Electrical Code 2005 article 430-10(b) for wiring space (Ref “P”) needed for line side conductors. 3. See Siemens I-T-E instructions for disconnect location limitations when using 36" or 48" Max-Flex™ cables. 4. Space occupied by circuit breaker is calculated by:

Charts reference Space Occupied by Disconnect Drawing.

"K" = 7.88 when "A" = 60.13 "K" = 13.88 when "A" = 72.13

Charts reference Space Occupied by Disconnect Drawing.

Use cable mechanism with circuit breaker and 9422-A1 handle mechanism Cable operators are offered in 3’, 5’, and 10’ lengths. Last 2 digits of part numbers above (30) are for 3’ cables

Space Occupied By Disconnect Switch 1. Square D Cable System permits circuit breaker locations separate from flange mounted handle mechanism. 2. See National Electrical Code 2005 article 430-10(b) for wiring space (Ref “P”) needed for line side conductors. 3. Select cable mechanism length based on disconnect location in enclosure. See Square D instructions for minimum cable bend radius. 4. Space occupied by circuit breaker is calculated by:

"K" = 7.88 when "A" = 60.13 "K" = 13.88 when "A" = 72.13

Charts reference Space Occupied by Disconnect Drawing.

  • ■Overall (Height "X" and Width "Y")
  • ■Minimum wire bend space (manufacturer specified)
  • ■Location "M" from right to left.
  • ■Overall (Height "X" and Width "Y")
  • ■Minimum wire bend space (manufacturer specified)
  • ■Location "M" from right to left.
  • ■Overall (Height "X" and Width "Y")
  • ■Minimum wire bend space (manufacturer specified)

2UD, 2UDF & 2UDCP

col1col2col3col4col5col6col7col8col9col10col11col12col13col14col15col16col17col18col19col20col21col22col23col24col25col26col27col28col29col30col31col32col33col34col35col36col37col38col39col40col41col42col43col44col45col46col47col48col49col50col51col52col53col54col55col56col57col58col59col60
ABB Controls Disconnect switch: Flange operated switch (fusible or non-fusible) Shaft: 12.13" deep enclosures use DSFHS-12 18.13" deep enclosures use DSFHS-17 24.13" deep enclosures, platform must be used with shaft (not included) Handle: DSFHN-HS12 Circuit breaker: Circuit breaker: ABB Operating mechanism Shaft: 12.13" deep enclosures use K7FHD-S12 18.13" deep enclosures use K7FHD-S17 24.13" deep enclosures, platform must be used with shaft (not included) Handle mechanism: K7FHD-HS12 Allen Bradley Bulletin 1494F flange mounted disconnect switch: Disconnect switch Fuse block adaptor (if required) Line and load connectors (if required) 1494D flange mounted circuit breaker operating mechanism, order: Circuit breaker: C-H Westinghouse Operating mechanism Slide mechanism Bulletin 1494U flange mounted disconnect switch, order: Disconnect switch Operating handle Connecting rod (long) Trailer fuse block kit (if required) Fuse kit (if required) Line and load connectors (if required) Bulletin 1494U flange mounted circuit breaker operating mechanism, order: Circuit breaker: C-H Westinghouse Operating mechanism Operating handle Connecting rod (long) When Allen Bradley 1494U devices are installed in 72" high enclosures with the operating handle mounted on the center post, an optional Allen Bradley channel support kit is recommended.ABB ControlsDisconnect switch:Flange operated switch (fusible or non-fusible) Shaft: 12.13" deep enclosures use DSFHS-12 18.13" deep enclosures use DSFHS-17 24.13" deep enclosures, platform must be used with shaft (not included) Handle: DSFHN-HS12Circuit breaker:Circuit breaker: ABB Operating mechanism Shaft: 12.13" deep enclosures use K7FHD-S12 18.13" deep enclosures use K7FHD-S17 24.13" deep enclosures, platform must be used with shaft (not included) Handle mechanism: K7FHD-HS12Allen BradleyBulletin 1494F flange mounted disconnect switch:Disconnect switch Fuse block adaptor (if required) Line and load connectors (if required)1494D flange mounted circuit breaker operating mechanism, order:Circuit breaker: C-H Westinghouse Operating mechanism Slide mechanismBulletin 1494U flange mounted disconnect switch, order:Disconnect switch Operating handle Connecting rod (long) Trailer fuse block kit (if required) Fuse kit (if required) Line and load connectors (if required)Bulletin 1494U flange mounted circuit breaker operating mechanism, order:Circuit breaker: C-H Westinghouse Operating mechanism Operating handle Connecting rod (long) When Allen Bradley 1494U devices are installed in 72" high enclosures with the operating handle mounted on the center post, an optional Allen Bradley channel support kit is recommended.C-H Westinghouse Type C361 disconnect switch: Disconnect switch with an operating mechanism Operating handle: C361H1 or C361H3 In 24.13" deep enclosures, platform must be used with shaft (not included) Type C371 circuit breaker operating mechanism with a C-H Westinghouse circuit breaker: Circuit breaker Operating mechanism Long operating rod (if required) Operating handle: 150 amp - C371H1 or C371H3 250 through 600 amp - C371H5 or C371H7 Flex-Shaft™ handle mechanism: Circuit breaker Complete Flex-Shaft™ handle mechanism General Electric Disconnect switch: Disconnect switch: Type QMR or QMW Fuse clip kit or no-fuse kit Flange handle: STDA1 or STDA2 Variable depth operating mechanism Extended length drive rod (if required) Circuit breaker: Circuit breaker Flange handle: STDA1 or STDA2 Variable depth operating mechanism Extended length drive rod (if required) An optional General Electric Flange Stiffener Kit (TDSR) is recommended when General Electric Type TDA devices are installed in 72.13" high enclosures with operating handle mounted on centerpost. Use with TDOM1, TDOM2, TDOM3, S100M1A, and S100M3 operating mechanisms. Circuit breaker with a Spectra-Flex™ cable operator: Circuit breaker Flange mounted handle mechanism: 150 to 600 amps - STDA1 SK1200 - STDA3 Breaker mounted mechanism Operating cableC-H WestinghouseType C361 disconnect switch:Disconnect switch with an operating mechanism Operating handle: C361H1 or C361H3 In 24.13" deep enclosures, platform must be used with shaft (not included)Type C371 circuit breaker operating mechanism with a C-H Westinghouse circuit breaker:Circuit breaker Operating mechanism Long operating rod (if required) Operating handle: 150 amp - C371H1 or C371H3 250 through 600 amp - C371H5 or C371H7Flex-Shaft™ handle mechanism:Circuit breaker Complete Flex-Shaft™ handle mechanismGeneral ElectricDisconnect switch:Disconnect switch: Type QMR or QMW Fuse clip kit or no-fuse kit Flange handle: STDA1 or STDA2 Variable depth operating mechanism Extended length drive rod (if required)Circuit breaker:Circuit breaker Flange handle: STDA1 or STDA2 Variable depth operating mechanism Extended length drive rod (if required) An optional General Electric Flange Stiffener Kit (TDSR) is recommended when General Electric Type TDA devices are installed in 72.13" high enclosures with operating handle mounted on centerpost. Use with TDOM1, TDOM2, TDOM3, S100M1A, and S100M3 operating mechanisms.Circuit breaker with a Spectra-Flex™ cable operator:Circuit breaker Flange mounted handle mechanism: 150 to 600 amps - STDA1 SK1200 - STDA3 Breaker mounted mechanism Operating cableI-T-E Siemens Disconnect switch: Basic switch (right-hand) Fuse or no-fuse kit Flange mounted handle: FHOHS Switch operator Operating cable: FHOEC036 cable for 12.13" deep FHOECO48 for 18.13" and 24.13" deep enclosures Circuit breaker: Circuit breaker Pressure wire connectors Flange mounted handle: 100 to 600 - FHOH 800 to 2000 - FHOHN Circuit breaker operator mechanism Operating cable: 36" cable for 12.13" or 18.13" deep 48" for 24.13" deep enclosures These items are available from Siemens I-T-E as a complete mechanism with a 36" operating cable only Order items separately when using a 48" cable Square D Disconnect switch: Disconnect switch with operating mechanism Universal handle mechanism: Type A-1 Long operating rod (if required) Circuit breaker: Circuit breaker Operating mechanism Universal handle mechanism: Type A-1 Long operating rod (if required) Class 9422 Type T disconnect switch with a cable mechanism: Disconnect switch with operating mechanism: Class 9422, Type T Handle mechanism: Class 9422, Type A-1 Cable mechanism: Class 9422 CFT_O, 3, 5, or 10 foot Circuit breaker with a cable mechanism: Circuit breaker: Square D Handle mechanism: Class 9422, type A-1 Cable mechanism: Class 9422 CFT_O, 3, 5, or 10 foot An optional Square D Channel flange Support Kit (9422-C1) is recommended when some Square D devices are installed in 72.13" high enclosures with operating handle mounted on centerpost.I-T-E SiemensDisconnect switch:Basic switch (right-hand) Fuse or no-fuse kit Flange mounted handle: FHOHS Switch operator Operating cable: FHOEC036 cable for 12.13" deep FHOECO48 for 18.13" and 24.13" deep enclosuresCircuit breaker:Circuit breaker Pressure wire connectors Flange mounted handle: 100 to 600 - FHOH 800 to 2000 - FHOHN Circuit breaker operator mechanism Operating cable: 36" cable for 12.13" or 18.13" deep 48" for 24.13" deep enclosures These items are available from Siemens I-T-E as a complete mechanism with a 36" operating cable only Order items separately when using a 48" cableSquare DDisconnect switch:Disconnect switch with operating mechanism Universal handle mechanism: Type A-1 Long operating rod (if required)Circuit breaker:Circuit breaker Operating mechanism Universal handle mechanism: Type A-1 Long operating rod (if required)Class 9422 Type T disconnect switch with a cable mechanism:Disconnect switch with operating mechanism: Class 9422, Type T Handle mechanism: Class 9422, Type A-1 Cable mechanism: Class 9422 CFT_O, 3, 5, or 10 footCircuit breaker with a cable mechanism:Circuit breaker: Square D Handle mechanism: Class 9422, type A-1 Cable mechanism: Class 9422 CFT_O, 3, 5, or 10 foot An optional Square D Channel flange Support Kit (9422-C1) is recommended when some Square D devices are installed in 72.13" high enclosures with operating handle mounted on centerpost.
ABB Controls
Disconnect switch:
Flange operated switch (fusible or non-fusible) Shaft: 12.13" deep enclosures use DSFHS-12 18.13" deep enclosures use DSFHS-17 24.13" deep enclosures, platform must be used with shaft (not included) Handle: DSFHN-HS12
Circuit breaker:
Circuit breaker: ABB Operating mechanism Shaft: 12.13" deep enclosures use K7FHD-S12 18.13" deep enclosures use K7FHD-S17 24.13" deep enclosures, platform must be used with shaft (not included) Handle mechanism: K7FHD-HS12
Allen Bradley
Bulletin 1494F flange mounted disconnect switch:
Disconnect switch Fuse block adaptor (if required) Line and load connectors (if required)
1494D flange mounted circuit breaker operating mechanism, order:
Circuit breaker: C-H Westinghouse Operating mechanism Slide mechanism
Bulletin 1494U flange mounted disconnect switch, order:
Disconnect switch Operating handle Connecting rod (long) Trailer fuse block kit (if required) Fuse kit (if required) Line and load connectors (if required)
Bulletin 1494U flange mounted circuit breaker operating mechanism, order:
Circuit breaker: C-H Westinghouse Operating mechanism Operating handle Connecting rod (long) When Allen Bradley 1494U devices are installed in 72" high enclosures with the operating handle mounted on the center post, an optional Allen Bradley channel support kit is recommended.
C-H Westinghouse
Type C361 disconnect switch:
Disconnect switch with an operating mechanism Operating handle: C361H1 or C361H3 In 24.13" deep enclosures, platform must be used with shaft (not included)
Type C371 circuit breaker operating mechanism with a C-H Westinghouse circuit breaker:
Circuit breaker Operating mechanism Long operating rod (if required) Operating handle: 150 amp - C371H1 or C371H3 250 through 600 amp - C371H5 or C371H7
Flex-Shaft™ handle mechanism:
Circuit breaker Complete Flex-Shaft™ handle mechanism
General Electric
Disconnect switch:
Disconnect switch: Type QMR or QMW Fuse clip kit or no-fuse kit Flange handle: STDA1 or STDA2 Variable depth operating mechanism Extended length drive rod (if required)
Circuit breaker:
Circuit breaker Flange handle: STDA1 or STDA2 Variable depth operating mechanism Extended length drive rod (if required) An optional General Electric Flange Stiffener Kit (TDSR) is recommended when General Electric Type TDA devices are installed in 72.13" high enclosures with operating handle mounted on centerpost. Use with TDOM1, TDOM2, TDOM3, S100M1A, and S100M3 operating mechanisms.
Circuit breaker with a Spectra-Flex™ cable operator:
Circuit breaker Flange mounted handle mechanism: 150 to 600 amps - STDA1 SK1200 - STDA3 Breaker mounted mechanism Operating cable
I-T-E Siemens
Disconnect switch:
Basic switch (right-hand) Fuse or no-fuse kit Flange mounted handle: FHOHS Switch operator Operating cable: FHOEC036 cable for 12.13" deep FHOECO48 for 18.13" and 24.13" deep enclosures
Circuit breaker:
Circuit breaker Pressure wire connectors Flange mounted handle: 100 to 600 - FHOH 800 to 2000 - FHOHN Circuit breaker operator mechanism Operating cable: 36" cable for 12.13" or 18.13" deep 48" for 24.13" deep enclosures These items are available from Siemens I-T-E as a complete mechanism with a 36" operating cable only Order items separately when using a 48" cable
Square D
Disconnect switch:
Disconnect switch with operating mechanism Universal handle mechanism: Type A-1 Long operating rod (if required)
Circuit breaker:
Circuit breaker Operating mechanism Universal handle mechanism: Type A-1 Long operating rod (if required)
Class 9422 Type T disconnect switch with a cable mechanism:
Disconnect switch with operating mechanism: Class 9422, Type T Handle mechanism: Class 9422, Type A-1 Cable mechanism: Class 9422 CFT_O, 3, 5, or 10 foot
Circuit breaker with a cable mechanism:
Circuit breaker: Square D Handle mechanism: Class 9422, type A-1 Cable mechanism: Class 9422 CFT_O, 3, 5, or 10 foot An optional Square D Channel flange Support Kit (9422-C1) is recommended when some Square D devices are installed in 72.13" high enclosures with operating handle mounted on centerpost.

2UD, 2UDF & 2UDCP

col1
ABB Controls
Disconnect switch:
Flange operated switch (fusible or non-fusible) Shaft: 12.13" deep enclosures use DSFHS-12 18.13" deep enclosures use DSFHS-17 24.13" deep enclosures, platform must be used with shaft (not included) Handle: DSFHN-HS12
Circuit breaker:
Circuit breaker: ABB Operating mechanism Shaft: 12.13" deep enclosures use K7FHD-S12 18.13" deep enclosures use K7FHD-S17 24.13" deep enclosures, platform must be used with shaft (not included) Handle mechanism: K7FHD-HS12
Allen Bradley
Bulletin 1494F flange mounted disconnect switch:
Disconnect switch Fuse block adaptor (if required) Line and load connectors (if required)
1494D flange mounted circuit breaker operating mechanism, order:
Circuit breaker: C-H Westinghouse Operating mechanism Slide mechanism
Bulletin 1494U flange mounted disconnect switch, order:
Disconnect switch Operating handle Connecting rod (long) Trailer fuse block kit (if required) Fuse kit (if required) Line and load connectors (if required)
Bulletin 1494U flange mounted circuit breaker operating mechanism, order:
Circuit breaker: C-H Westinghouse Operating mechanism Operating handle Connecting rod (long) When Allen Bradley 1494U devices are installed in 72" high enclosures with the operating handle mounted on the center post, an optional Allen Bradley channel support kit is recommended.

2UD, 2UDF & 2UDCP

col1
C-H Westinghouse
Type C361 disconnect switch:
Disconnect switch with an operating mechanism Operating handle: C361H1 or C361H3 In 24.13" deep enclosures, platform must be used with shaft (not included)
Type C371 circuit breaker operating mechanism with a C-H Westinghouse circuit breaker:
Circuit breaker Operating mechanism Long operating rod (if required) Operating handle: 150 amp - C371H1 or C371H3 250 through 600 amp - C371H5 or C371H7
Flex-Shaft™ handle mechanism:
Circuit breaker Complete Flex-Shaft™ handle mechanism
General Electric
Disconnect switch:
Disconnect switch: Type QMR or QMW Fuse clip kit or no-fuse kit Flange handle: STDA1 or STDA2 Variable depth operating mechanism Extended length drive rod (if required)
Circuit breaker:
Circuit breaker Flange handle: STDA1 or STDA2 Variable depth operating mechanism Extended length drive rod (if required) An optional General Electric Flange Stiffener Kit (TDSR) is recommended when General Electric Type TDA devices are installed in 72.13" high enclosures with operating handle mounted on centerpost. Use with TDOM1, TDOM2, TDOM3, S100M1A, and S100M3 operating mechanisms.
Circuit breaker with a Spectra-Flex™ cable operator:
Circuit breaker Flange mounted handle mechanism: 150 to 600 amps - STDA1 SK1200 - STDA3 Breaker mounted mechanism Operating cable

2UD, 2UDF & 2UDCP

col1
I-T-E Siemens
Disconnect switch:
Basic switch (right-hand) Fuse or no-fuse kit Flange mounted handle: FHOHS Switch operator Operating cable: FHOEC036 cable for 12.13" deep FHOECO48 for 18.13" and 24.13" deep enclosures
Circuit breaker:
Circuit breaker Pressure wire connectors Flange mounted handle: 100 to 600 - FHOH 800 to 2000 - FHOHN Circuit breaker operator mechanism Operating cable: 36" cable for 12.13" or 18.13" deep 48" for 24.13" deep enclosures These items are available from Siemens I-T-E as a complete mechanism with a 36" operating cable only Order items separately when using a 48" cable
Square D
Disconnect switch:
Disconnect switch with operating mechanism Universal handle mechanism: Type A-1 Long operating rod (if required)
Circuit breaker:
Circuit breaker Operating mechanism Universal handle mechanism: Type A-1 Long operating rod (if required)
Class 9422 Type T disconnect switch with a cable mechanism:
Disconnect switch with operating mechanism: Class 9422, Type T Handle mechanism: Class 9422, Type A-1 Cable mechanism: Class 9422 CFT_O, 3, 5, or 10 foot
Circuit breaker with a cable mechanism:
Circuit breaker: Square D Handle mechanism: Class 9422, type A-1 Cable mechanism: Class 9422 CFT_O, 3, 5, or 10 foot An optional Square D Channel flange Support Kit (9422-C1) is recommended when some Square D devices are installed in 72.13" high enclosures with operating handle mounted on centerpost.

2UD, 2UDF & 2UDCP

col1col2col3col4col5col6col7col8col9col10col11
Fits Enclosure HeightFits Enclosure HeightABB Switch NumberAmpSpace OccupiedWhen A=60.13 PWhen A=72.13 P
60.1372.13ABB Switch NumberRatingFuse ClipFuse ClassLMNWhen A=60.13 PWhen A=72.13 P
••OETL-NF30-F30ANo Fuse—4.453.910.259.5315.53
••OETL-NF60-F60ANo Fuse—4.863.910.259.3415.34
••OETL-NF100-F100ANo Fuse—4.864.910.258.7814.78
••OETL-NF175-F175ANo Fuse—7.306.620.256.5312.53
••OETL-NF200-F200ANo Fuse—7.367.410.256.5312.53
••OESA-F30J6-F30A30A-600VJ4.286.700.257.8513.86
••OESA-F60J6-F60A60A-600VJ4.286.390.257.8513.86
••OESA-F100J6-F100A100A-600VJ¹6.547.780.257.4213.42
200A²

2UD, 2UDF & 2UDCP

col1col2col3col4col5col6col7col8col9col10col11
Fits Enclosure HeightFits Enclosure HeightISOMAX Circuit BreakerAmp RatingOperating MechanismFrame TypeSpace OccupiedSpace OccupiedWhen A=60.13 PWhen A=72.13 P
60.1372.13ISOMAX Circuit BreakerAmp RatingOperating MechanismFrame TypeLMNWhen A=60.13 PWhen A=72.13 P
••S1N100TL100AK2FHD-MS15.304.600.638.3314.33
••S3N150TW150AK3FHD-MS36.675.020.637.7313.73
••S3N225TW225AK3FHD-MS36.675.020.637.7313.73
••S4N250BW250AK4FHD-MS48.455.020.636.2012.20
••S5N400TW400AK5FHD-MS58.456.400.636.2012.20
••S6N600TW600AK6FHD-MS68.3310.000.635.5311.53
••S6N800TW800AK6FHD-MS68.3310.000.635.5311.53

2UD, 2UDF & 2UDCP

col1col2col3col4col5col6col7col8col9col10col11
Fits Enclosure HeightFits Enclosure HeightAllen Bradley Switch NumberAmp RatingSpace Occupied M¹When A=60.13 PWhen A=72.13 P
60.1372.13Allen Bradley Switch NumberAmp RatingFuse ClipFuse ClassLSpace Occupied M¹NWhen A=60.13 PWhen A=72.13 P
••N3030ANo Fuse—4.626.500.635.3111.31
••NF3030A30A-250VH, K, R6.506.500.635.3111.31
••NF3030A60A-250VH, K, R7.256.500.635.3111.31
••NF3030A30A-600VH, K, R9.256.500.635.3111.31
••NF3030A60A-600VH, K, R9.756.500.635.3111.31
••NF3030A30A-600VJ6.506.500.635.3111.31
••NF3030A60A-600VJ6.626.500.635.3111.31
••N6060ANo Fuse—4.626.500.634.6210.62
••NF6060A30A-600VH, K, R10.386.500.634.6210.62
••NF6060A60A-250VH, K, R8.386.500.634.6210.62
••NF6060A100A-250VH, K, R10.886.500.634.6210.62
••NF6060A60A-600VH, K, R10.886.500.634.6210.62
••NF6060A100A-600VH, K, R12.886.620.634.6210.62
••NF6060A60A-600VJ7.756.500.634.6210.62
••NF6060A100A-600VJ9.756.500.634.6210.62
•N100100ANo Fuse—4.627.250.63—8.75
•NF100100A100A-250VH, K, R11.387.380.63—8.75
•NF100100A200A-250VH, K, R12.257.620.63—8.75
•NF100100A100A-600VH, K, R13.387.500.63—8.75
•NF100100A200A-600VH, K, R14.757.750.63—8.75
•NF100100A100A-600VJ10.127.380.63—8.75
•NF100100A200A-600VJ10.887.500.63—8.75
•N200200ANo Fuse—7.1210.380.56—7.13
•NF200200A200A-250VH, K, R15.0010.380.56—7.13
•NF200200A400A-250VH, K, R16.5610.750.56—7.13
•NF200200A200A-600VH, K, R17.5610.380.56—7.13
•NF200200A400A-600VH, K, R19.5611.000.56—7.13
•NF200200A200A-600VJ13.6910.380.56—7.13
•NF200200A400A-600VJ15.0010.620.56—7.13

2UD, 2UDF & 2UDCP

col1col2col3col4col5col6col7col8col9col10
Fits Enclosure HeightFits Enclosure HeightAlan Bradley Type NumberAmp RatingCircuit Breker TypeSpace OccupiedWhen A=60.13 PWhen A=72.13 P
60.1372.13Alan Bradley Type NumberAmp RatingCircuit Breker TypeLM¹NWhen A=60.13 PWhen A=72.13 P
••N4/N40150AC-H Westinghouse EHD,FD,FDB,FDC,HFD,HMCP5.814.560.635.2511.25
••N5/N55225AGeneral Electric TFK, THFK, TFC8.814.750.634.4410.44
••N5/N50250AC-H Westinghouse JD,JDB,JDC,HJD,HMCP8.814.750.634.4410.44
•N5/N60400AC-H Westinghouse KD,KDB,DK,HKD,HMCP8.815.880.63—10.50

2UD, 2UDF & 2UDCP

col1col2col3col4col5col6col7col8col9col10col11
Fits Enclosure HeightFits Enclosure HeightAlan Bradley Switch NumberAmpSpace OccupiedWhen A=60.13 PWhen A=72.13 P
60.1372.13Alan Bradley Switch NumberRatingFuse ClipFuse ClassLM²NWhen A=60.13 PWhen A=72.13 P
••DS3030ANo Fuse—3.886.751.066.0012.00
••DS3030A30A-250VH,K,R5.256.751.066.0012.00
••DS3030A30A-600VH,K,R8.006.751.066.0012.00
••DS3030A30A-600VJ5.256.751.066.0012.00
••DS3030A60A-250VH,K6.006.751.066.0012.00
••DS3030A60A-600VH,K8.506.751.066.0012.00
••DS3030A60A-600VJ5.386.751.066.0012.00
••DS6060ANo Fuse—3.886.751.065.8111.81
••DS6060A60A-250VH,K,R6.006.751.065.8111.81
••DS6060A60A-600VH,K,R8.506.751.065.8111.81
••DS6060A60A-600VJ5.386.751.065.8111.81
••DS6060A30A-600VH,K,R8.006.751.065.8111.81
••DS6060A100A-250VH,K8.506.751.065.8111.81
••DS6060A100A-600VH,K10.506.751.065.8111.81
••DS6060A100A-600VJ7.256.751.065.8111.81
••DS100¹100ANo Fuse—3.886.751.065.8111.81
••DS100¹100A100A-250VH,K,R8.126.751.065.8111.81
••DS100¹100A100A-600VH,K,R10.126.751.065.8111.81
••DS100¹100A100A-600VJ6.806.751.065.8111.81
••DS100¹100A60A-600VH,K,R10.126.751.065.8111.81
••DS100¹100A60A-600VJ8.886.751.065.8111.81
•DS2001200ANo Fuse—4.758.001.06—10.34
•DS2001200A200A-250VH,K,R10.888.001.06—10.34
•DS2001200A200A-600VH,K,R13.888.001.06—10.34
•DS2001200A200A-600VJ9.508.001.06—10.34
•DS2001200A100A-600VH,K,R12.008.001.06—10.34
•DS2001200A100A-600VJ8.758.001.06—10.34

2UD, 2UDF & 2UDCP

col1col2col3col4col5col6col7col8col9col10
Fits Enclosure HeightFits Enclosure HeightAlan Bradley Type NumberAmpSpace OccupiedWhen A=60.13 PWhen A=72.13 P
60.1372.13Alan Bradley Type NumberRatingCircuit Breker TypeLM1NWhen A=60.13 PWhen A=72.13 P
••M4015A-150AC-H Westinghouse EHD,FD,FDB,FDC,HFD,HMCP5.004.621.067.2513.25
••M5070A-250AC-H Westinghouse JD,JDB,JDC,HJD,HMCP9.754.881.066.8112.81
•M60100A-400AC-H Westinghouse KD,KDB,DK,HKD,HMCP9.696.251.06—12.62

2UD, 2UDF & 2UDCP

col1col2col3col4col5col6col7col8col9col10col11
Fits Enclosure HeightFits Enclosure HeightCutler Hammer Type NumberAmpSpace OccupiedWhen A=60.13 PWhen A=72.13 P
60.1372.13Cutler Hammer Type NumberRatingFuse ClipFuse ClassLMNWhen A=60.13 PWhen A=72.13 P
••C361NC30ANo Fuse—5.757.550.636.5012.50
••C361SC2130A30A-250VH, K, R8.387.550.636.5012.50
••C361SC6130A60A-250VH, K, R8.387.550.636.5012.50
••C361SC6130A30A-600VH, J, K, R8.387.550.636.5012.50
••C361ND60ANo Fuse—5.757.550.636.5012.50
••C361SD2260A60A-250VH, K, R8.387.550.636.5012.50
••C361SD2260A30A-600VJ8.387.550.636.5012.50
••C361SD6260A60A-600VH, K, R8.387.550.636.5012.50
••C361SD6260A60A-600VJ8.387.550.636.5012.50
••C361NE100ANo Fuse—5.569.070.636.0612.06
••C361SE263100A100A-250VH, K, R10.319.070.636.0612.06
••C361SE263100A100A-600VH, K, R10.319.070.636.0612.06
••C361SE263100A100A-600VJ10.319.070.636.0612.06
••C361NF200ANo Fuse—13.0610.120.634.0610.12
••C361SF264200A200A-250VH, K, R13.0610.120.634.0610.12
••C361SF264200A200A-600VH, K, R, J13.0610.120.634.0610.12

2UD, 2UDF & 2UDCP

col1col2col3col4col5col6col7col8col9col10
Fits Enclosure HeightFits Enclosure HeightCutler Hammer MechanismsAmpSpace OccupiedWhen A=60.13 PWhen A=72.13 P
60.1372.13Cutler Hammer MechanismsRatingFrame TypeLMNWhen A=60.13 PWhen A=72.13 P
••C371E150AF Frame EHD,FDB,FD,HFD,FDC6.005.620.637.6213.62
••C371E150AF Frame HMCP6.005.620.637.6213.62
¹•C371F250AJ Frame JDB,JD,HJD,JDC8.948.120.637.5013.50
¹•C371F250AJ Frame HMCP10.948.120.637.5013.50
¹•C371F400AK Frame DK,KDB,KD,HKD9.758.120.637.0013.00
¹•C371F400AK Frame HMCP9.758.120.637.0013.00
²C371G600AL Frame LD,HLD,LDC8.4412.000.63-11.38
²C371G600AL Frame HMCP8.4412.000.63-11.38

2UD, 2UDF & 2UDCP

col1col2col3col4col5
Complete OperatorBreaker Height "X"Breaker Width "Y"
MechanismsAmp RatingFrame Type(in inches)(in inches)
F1S03150AF Frame EHD,FDB,FD,HFD6.004.12
F1S03150AF Frame HCMP6.004.12
F2S03250AJ Frame JDB,JD,HJD,JDC10.004.12
F2S03250AJ Frame HCMP10.004.12
F3S03400AK Frame DK,KDB,KD,HKD10.125.50
F3S03400AK Frame HCMP12.455.50
F4S04600AL Frame LD,HLD,LDC10.758.25
F7S04800AM Frame MD,MDS16.008.25
F5S041200AN Frame ND,HND,NDC16.008.25
F6S042500AR Frame RD,CRD, RDC16.0015.50

2UD, 2UDF & 2UDCP

col1col2col3col4col5col6col7col8col9col10col11
Fits Enclosure HeightFits Enclosure HeightGeneral Electric Switch MechanismsAmp RatingSpace Occupied MWhen A=60.13 PWhen A=72.13 P
60.1372.13General Electric Switch MechanismsAmp RatingFuse ClipFuse ClassLSpace Occupied MNWhen A=60.13 PWhen A=72.13 P
••TDOM1A30ANo Fuse-6.885.380.638.3814.38
••TDOM1A30A30A-250VH, R6.885.380.638.3814.38
••TDOM1B30A30A-600VH, R11.55.380.638.3814.38
••TDOM1B30A60A-250VH, R11.55.380.638.3814.38
••TDOM1B30A60A-600VH, R11.55.380.638.3814.38
••TDOM1A60ANo Fuse-6.885.380.638.3814.38
••TDOM1B60A60A-250VH, R11.55.380.638.3814.38
••TDOM1B60A60A-600VH, R11.55.380.638.3814.38
••TDOM1B60A100A-250VH, R11.55.380.638.3814.38
••TDOM1B60A100A-600VH, R11.55.380.638.3814.38
••TDOM1A100ANo Fuse-6.885.380.638.3814.38
••TDOM1B100A100A-250VH, R11.55.380.638.3814.38
••TDOM1B100A100A-600VH, R11.55.380.638.3814.38
••TDOM1B100A200A-250VH, R11.55.380.638.3814.38
••TDOM1B100A200A-600VH, R11.55.380.638.3814.38
••TDOM2200ANo Fuse-79.250.635.6911.69
••TDOM2200A200A-250VH, R15.389.250.635.6911.69
••TDOM2200A200A-600VH, R15.389.250.635.6911.69

2UD, 2UDF & 2UDCP

col1col2col3col4col5col6col7col8col9col10
Fits Enclosure HeightFits Enclosure HeightGeneral Electric Circuit Breaker MechanismsAmp RatingFrame TypeSpace OccupiedSpace OccupiedWhen A=60.13 PWhen A=72.13 P
60.1372.13General Electric Circuit Breaker MechanismsAmp RatingFrame TypeLMNWhen A=60.13 PWhen A=72.13 P
••TDOM1A150ATEB, TED, THED6.885.380.637.2413.24
••TDOM1A150ATEC6.885.380.637.2413.24
••TDOM1B150ATB111.505.380.637.2413.24
••TDOM1B150ATEC, TECL11.505.380.637.2413.24
••TDOM1C150ATEL6.885.380.637.2413.24
••TDOM1D150ATHLC16.885.380.635.8711.87
••TDOM3225ATFJ10.385.880.636.8112.81
••TDOM3225ATFK, THFK, TFL10.385.880.636.8112.81
•TDOM4400ATJJ, TJK4, THJK4, TJL4V8.259.500.63—11.91
•TDOM4600ATJK6, THJK6, TJ4V, TJL4V8.259.500.63—11.91
•TDOM5400ATB4, TJH6S14.259.500.63—11.91
•TDOM6225ATLB2, THLC211.759.500.63—11.35
•TDOM6400ATLB4, THLC411.759.500.63—9.97
••SDOM1A150ASE1506.885.380.637.2413.24
••SDOM3250ASPECTRA SF25010.385.880.636.8111.88
•SDOM4600ASPECTRA SG60010.007.120.63—9.18

2UD, 2UDF & 2UDCP

col1col2col3col4col5col6
Fits Enclosure HeightFits Enclosure HeightCircuit Breaker HeightCircuit Breaker Width
60.1372.13Frame SizeMax Amp Rating"X""Y"
••E150150A6.314.12
••SE150150A6.314.12
••SF250250A10.124.12
••SG600600A10.095.50
••SK12001200A15.508.25

2UD, 2UDF & 2UDCP

col1col2col3col4
Frame SizeBreaker MechanismFlange Mounting Handle¹Operating Cable²
E150SCOM1ASCH1SC3L
SE150/SF250SCOM1EFSCH1SC3L
SG600SCOM1GSCH1SC3L
SK1200SCOM1KSCH2KSC3H

2UD, 2UDF & 2UDCP

col1col2col3col4col5col6col7col8
Fits Enclosure DepthFits Enclosure DepthAmpDisconnect Height "X"Disconnect Width "Y"
60.1372.13SwitchRatingFuse ClipFuse ClassDisconnect Height "X"Disconnect Width "Y"
••MCS603R30ANo Fuse—5.526.13
••MCS603R30A30A-250VH,K,R8.116.13
••MCS603R30A30A-600VH,K,R10.116.13
••MCS603R30A30A-600VJ8.486.13
••MCS606R60ANo Fuse—5.526.13
••MCS606R60A60A-250VH,K,R7.866.13
••MCS606R60A60A-600VH,K,R10.386.13
••MCS606R60A60A-600VJ8.366.13
••MCS610R100ANo Fuse—7.597.38
••MCS610R100A100A-250VH,K,R11.857.38
••MCS610R100A100A-600VH,K,R13.857.38
••MCS610R100A100A-600VJ10.607.38
••MCS620R200ANo Fuse—9.009.17
••MCS620R200A200A-250VH,K,R14.709.17
••MCS620R200A200A-600VH,K,R17.209.17
••MCS620R200A200A-600VJ13.329.17

2UD, 2UDF & 2UDCP

col1col2col3col4col5col6
Complete Operator MechansimAmp RatingBreaker Frame SizeCircuit Breaker Height "X"Circuit Breaker Width "Y"
Complete Operator MechansimAmp RatingBreaker Frame SizeCircuit Breaker TypeCircuit Breaker Height "X"Circuit Breaker Width "Y"
FHOE036125AEDED2, ED4, ED6, HED4, HED66.343.00
FHOE036125ACEDCED69.583.00
FHOF036250AFDFXD6-A, FD6-A, HFD6, FXD6ETJ, HHFD6, HHFXD69.504.50
FHOF036250ACFDCFD6, CFD6-ETI14.254.50
FHOJ036400A, 600AJD, LDJXD2, LXD6, JD6, LD6, HJD6, HLD6, HHJD6, HHLD6, HHJXD6, HHLDX6, JXD6-ETI, LXD6-ETI11.007.50
FHOJ036400A, 600ACJD,CLDCJD6, CLD6, CJD6-ETI, CLD6-ETI17.867.50
FHOLMO36800ALMDLMD6, LMXD6, HLMD6, HLMXD6, LMXD6-ETI16.009.00
FHON048800A, 1200AMD, NDMD6, ND6, MXD6, NXD6, HMD6, HND6, HMXD6, HNXD6, CMD6, CND6, MXD6-ETI, CMD6-ETI24.009.00
FHONO481600A, 2000APD,RDPD6, RD6, PXD6, RXD6, HPD6, HRD6, HPXD6, HRXD6, CPD624.50(2)13.63(2)

2UD, 2UDF & 2UDCP

col1col2col3col4col5col6col7col8col9col10col11
Fits Enclosure HeightFits Enclosure HeightSquare D Amp NumberAmp RatingSpace OccupiedSpace OccupiedWhen A=60.13 PWhen A=72.13 P
60.1372.13Square D Amp NumberAmp RatingFuse ClipFuse ClassLMNWhen A=60.13 PWhen A=72.13 P
••TCN-3030ANo Fuse—3.806.970.636.7512.75
••TCF-3030A30A-250VH, K, R5.536.970.636.7512.75
••TCF-3330A30A-600VH, K, R8.156.970.636.7512.75
••TCF-3330A60A-250VH, K, R6.156.970.636.7512.75
••TCF-3330A30A-600VJ5.536.970.636.7512.75
••TDN-6060ANo Fuse—3.806.970.636.7512.75
••TDF-6060A30A-600VH, K, R8.156.970.636.7512.75
••TDF-6060A60A-250VH, K, R6.156.970.636.7512.75
••TDF-6360A60A-600VH, K, R8.656.970.636.7512.75
••TDF-6360A60A-600VJ5.536.970.636.7512.75
••TEN-10100ANo Fuse—3.806.970.636.6212.62
••TEF-10100A100A-250VH, K, R8.256.970.636.6212.62
••TEF-10100A100A-600VH, K, R10.256.970.636.6212.62
••TEF-10100A100A-600VJ7.056.970.636.6212.62
••TEF-13100A200A-600VJ——0.636.6212.62
••TC-130ANo Fuse‑5.756.120.635.8811.88
••TC-230A30A-250VH, K, R5.756.120.635.8811.88
••TC-330A30A-600VH, K, R7.756.120.635.8811.88
••TC-330A60A-250VH, K, R5.886.120.635.8811.88
••TC-330A30A-600VJ5.756.120.635.8811.88
••TD-160ANo Fuse—6.386.750.636.7512.75
••TD-260A30A-600VH, K, R8.506.750.636.7512.75
••TD-260A60A-250VH, K, R6.506.750.636.7512.75
••TD-360A60A-600VH, K, R9.006.750.636.7512.75
••TD-360A60A-600VJ6.386.750.636.7512.75
••TE-1100ANo Fuse—4.758.500.636.5012.50
••TE-2100A100A-250VH, K, R7.508.500.636.5012.50
••TE-2100A100A-600VH, K, R9.508.500.636.5012.50
••TE-2100A100A-600VJ6.258.500.636.5012.50
••TE-3100A200A-600VJ13.758.500.636.5012.50
••TF-1200ANo Fuse—5.5011.750.635.1211.12
••TF-2200A200A-250VH, K, R11.5011.750.635.1211.12
••TF-2200A200A-600VH, K, R14.0011.750.635.1211.12
••TF-2200A200A-600VJ10.1211.750.635.1211.12
••TF-3200A400A-600VJ14.5011.750.635.1211.12

2UD, 2UDF & 2UDCP

col1col2col3col4col5col6col7col8col9col10
Fits Enclosure DepthFits Enclosure DepthSquare D Type NumberAmp RatingSpace OccupiedSpace OccupiedWhen A=60.13 PWhen A=72.13 P
60.1372.13Square D Type NumberAmp RatingFrame SizeLMNWhen A=60.13 PWhen A=72.13 P
••RG-175AGJL3.533.870.636.6912.69
••RG-1100AGJL3.533.870.636.6912.69
••RN-1100AFAL, FHL5.125.380.636.8812.88
••RP-1250AKAL, KHL7.125.750.637.5613.56
•RR-1400ALAL, LHL, Q4L7.628.880.63—9.25

2UD, 2UDF & 2UDCP

col1col2col3col4col5col6col7col8
Fits Enclosure DepthFits Enclosure DepthSquare D Type NumberAmp RatingFuse ClipFuse ClassDisconnect Height "X"Disconnect Width "Y"
A=60.13A=72.13Square D Type NumberAmp RatingFuse ClipFuse ClassDisconnect Height "X"Disconnect Width "Y"
PPSquare D Type NumberAmp RatingFuse ClipFuse ClassDisconnect Height "X"Disconnect Width "Y"
••TCN-3030ANo Fuse—5.906.20
••TCF-3030A30A-250VH, K, R7.506.20
••TCF-3330A30A-600VH, K, R10.156.20
••TCF-3330A60A-250VH, K, R8.156.20
••TCF-3330A30A-600VJ7.506.20
••TDN-6060ANo Fuse—5.906.20
••TDF-6060A30A-600VH, K, R10.156.20
••TDF-6060A60A-250VH, K, R8.156.20
••TDF-6360A60A-600VH, K, R10.656.20
••TDF-6360A60A-600VJ7.506.20
••TEN-10100ANo Fuse—5.906.20
••TEF-10100A100A-250VH, K, R10.356.20
••TEF-10100A100A-600VH, K, R10.356.20
••TEF-10100A100A-600VJ10.356.20

2UD, 2UDF & 2UDCP

col1col2col3col4col5col6col7
Fits Enclosure DepthFits Enclosure Depth
A=60.13A=72.13Circuit BreakerCircuit Breaker
PPCable Type SwitchAmp RatingFrame TypeHeight "X"Width "Y"
••9422 CGJ3075AGJL4.753.50
••9422 CEJ30100AGJL4.753.50
••9422 CFA30100AFAL,FHL6.004.50
••9422 CKA30250AKAL,KHL8.004.50
••9422 CLA30400ALAL,LHL,Q4L11.006.00