Two Door Selection Guide
ABB Controls Disconnect Switches (Flange Mounted Operators)
¹ "M" dimension does not allow for auxiliary switches. Refer to Allen Bradley instructions if additional space is required.
Allen Bradley 1494D Operators (Circuit Breakers)
1 "M" dimension does not allow for auxiliary switches. Refer to Allen Bradley instructions if additional space is required. "K" = 5.88 when "A" = 60.13 "K" = 11.88 when "A" = 72.13 (except 200A switches) "K" = 10.56 when "A" = 72.13 (200A switches only).
Allen Bradley 1494U Operators (Disconnect Switches)
1 Series B 2 "M" dimension does not allow for auxiliary switches
Allen Bradley 1494U Operators (Circuit Breakers)
1 "M" dimension does not allow for auxiliary switches. Refer to Allen Bradley instructions if additional space is required. "K" = 7.88 when "A" = 60.13 "K" = 13.88 when "A" = 72.13
Cutler Hammer Cutler Hammer C361 Disconnect Switches
Part numbers for Complete Operator Mechanisms include flange mounted handle, flexible shaft and circuit breaker mechanism. The last digit of the part number denotes the shaft length (F1S03=3' length). F,J,K frame Flex-Shafts™ available in 3' to 10' lengths. L,N,R frame Flex-Shafts™ available in 4' to 6' lengths.
Space Occupied By Disconnect 1. Flex-Shaft™ System permits circuit breaker locations separate from flange mounted handle mechanism. 2. See National Electrical Code 2005 article 430-10(b) for wiring space (Ref "P") needed for line side conductors. 3. Select shaft length based on location of circuit breaker in the enclosure. Maintain a 4" minimum bending radius for the Flex-Shaft™. 4. Space occupied by circuit breaker is calculated by:
Charts reference Space Occupied by Disconnect Drawing
Space Occupied By Disconnect 1. GE Spectra-Flex™ Operating Cables permit circuit breaker locations separate from flange mounted handle mechanism. 2. See National Electrical Code 2005 article 430-10(b) for wiring space (Ref "P") needed for line side conductors. 3. Select shaft length based on location of circuit breaker in the enclosure. Maintain a 3" minimum bending radius for the Flex-Shaft™. 4. Space occupied by circuit breaker is calculated by: Overall (Height "X" and Width "Y") Minimum wire bend space (manufacturer specified) Location "M" from right to left.
"K" = 7.88 when "A" = 60.13 "K" = 13.88 when "A" = 72.13
Charts reference Space Occupied by Disconnect Drawing.
Circuit Breaker Size includes required base mounting block. Last three digits of operator mechanism part number denote cable length in inches. 24" deep enclosures require longer operating cables. Sold separately. "K" = 7.88 when "A" = 60.13 "K" = 13.88 when "A" = 72.13 (Deduct 1.45 inches from "K" for FHONO48 Operator mechanism for MD,ND,PD,RD Circuit Breakers)
Space Occupied By Disconnect 1. Siemens I-T-E Max-Flex™ System permits circuit breaker locations separate from flange mounted handle mechanism. 2. See National Electrical Code 2005 article 430-10(b) for wiring space (Ref “P”) needed for line side conductors. 3. See Siemens I-T-E instructions for disconnect location limitations when using 36" or 48" Max-Flex™ cables. 4. Space occupied by circuit breaker is calculated by:
Charts reference Space Occupied by Disconnect Drawing.
"K" = 7.88 when "A" = 60.13 "K" = 13.88 when "A" = 72.13
Charts reference Space Occupied by Disconnect Drawing.
Use cable mechanism with circuit breaker and 9422-A1 handle mechanism Cable operators are offered in 3’, 5’, and 10’ lengths. Last 2 digits of part numbers above (30) are for 3’ cables
Space Occupied By Disconnect Switch 1. Square D Cable System permits circuit breaker locations separate from flange mounted handle mechanism. 2. See National Electrical Code 2005 article 430-10(b) for wiring space (Ref “P”) needed for line side conductors. 3. Select cable mechanism length based on disconnect location in enclosure. See Square D instructions for minimum cable bend radius. 4. Space occupied by circuit breaker is calculated by:
"K" = 7.88 when "A" = 60.13 "K" = 13.88 when "A" = 72.13
Charts reference Space Occupied by Disconnect Drawing.
- ■Overall (Height "X" and Width "Y")
- ■Minimum wire bend space (manufacturer specified)
- ■Location "M" from right to left.
- ■Overall (Height "X" and Width "Y")
- ■Minimum wire bend space (manufacturer specified)
- ■Location "M" from right to left.
- ■Overall (Height "X" and Width "Y")
- ■Minimum wire bend space (manufacturer specified)
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 | col6 | col7 | col8 | col9 | col10 | col11 | col12 | col13 | col14 | col15 | col16 | col17 | col18 | col19 | col20 | col21 | col22 | col23 | col24 | col25 | col26 | col27 | col28 | col29 | col30 | col31 | col32 | col33 | col34 | col35 | col36 | col37 | col38 | col39 | col40 | col41 | col42 | col43 | col44 | col45 | col46 | col47 | col48 | col49 | col50 | col51 | col52 | col53 | col54 | col55 | col56 | col57 | col58 | col59 | col60 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ABB Controls Disconnect switch: Flange operated switch (fusible or non-fusible) Shaft: 12.13" deep enclosures use DSFHS-12 18.13" deep enclosures use DSFHS-17 24.13" deep enclosures, platform must be used with shaft (not included) Handle: DSFHN-HS12 Circuit breaker: Circuit breaker: ABB Operating mechanism Shaft: 12.13" deep enclosures use K7FHD-S12 18.13" deep enclosures use K7FHD-S17 24.13" deep enclosures, platform must be used with shaft (not included) Handle mechanism: K7FHD-HS12 Allen Bradley Bulletin 1494F flange mounted disconnect switch: Disconnect switch Fuse block adaptor (if required) Line and load connectors (if required) 1494D flange mounted circuit breaker operating mechanism, order: Circuit breaker: C-H Westinghouse Operating mechanism Slide mechanism Bulletin 1494U flange mounted disconnect switch, order: Disconnect switch Operating handle Connecting rod (long) Trailer fuse block kit (if required) Fuse kit (if required) Line and load connectors (if required) Bulletin 1494U flange mounted circuit breaker operating mechanism, order: Circuit breaker: C-H Westinghouse Operating mechanism Operating handle Connecting rod (long) When Allen Bradley 1494U devices are installed in 72" high enclosures with the operating handle mounted on the center post, an optional Allen Bradley channel support kit is recommended. | ABB Controls | Disconnect switch: | Flange operated switch (fusible or non-fusible) Shaft: 12.13" deep enclosures use DSFHS-12 18.13" deep enclosures use DSFHS-17 24.13" deep enclosures, platform must be used with shaft (not included) Handle: DSFHN-HS12 | Circuit breaker: | Circuit breaker: ABB Operating mechanism Shaft: 12.13" deep enclosures use K7FHD-S12 18.13" deep enclosures use K7FHD-S17 24.13" deep enclosures, platform must be used with shaft (not included) Handle mechanism: K7FHD-HS12 | Allen Bradley | Bulletin 1494F flange mounted disconnect switch: | Disconnect switch Fuse block adaptor (if required) Line and load connectors (if required) | 1494D flange mounted circuit breaker operating mechanism, order: | Circuit breaker: C-H Westinghouse Operating mechanism Slide mechanism | Bulletin 1494U flange mounted disconnect switch, order: | Disconnect switch Operating handle Connecting rod (long) Trailer fuse block kit (if required) Fuse kit (if required) Line and load connectors (if required) | Bulletin 1494U flange mounted circuit breaker operating mechanism, order: | Circuit breaker: C-H Westinghouse Operating mechanism Operating handle Connecting rod (long) When Allen Bradley 1494U devices are installed in 72" high enclosures with the operating handle mounted on the center post, an optional Allen Bradley channel support kit is recommended. | C-H Westinghouse Type C361 disconnect switch: Disconnect switch with an operating mechanism Operating handle: C361H1 or C361H3 In 24.13" deep enclosures, platform must be used with shaft (not included) Type C371 circuit breaker operating mechanism with a C-H Westinghouse circuit breaker: Circuit breaker Operating mechanism Long operating rod (if required) Operating handle: 150 amp - C371H1 or C371H3 250 through 600 amp - C371H5 or C371H7 Flex-Shaft™ handle mechanism: Circuit breaker Complete Flex-Shaft™ handle mechanism General Electric Disconnect switch: Disconnect switch: Type QMR or QMW Fuse clip kit or no-fuse kit Flange handle: STDA1 or STDA2 Variable depth operating mechanism Extended length drive rod (if required) Circuit breaker: Circuit breaker Flange handle: STDA1 or STDA2 Variable depth operating mechanism Extended length drive rod (if required) An optional General Electric Flange Stiffener Kit (TDSR) is recommended when General Electric Type TDA devices are installed in 72.13" high enclosures with operating handle mounted on centerpost. Use with TDOM1, TDOM2, TDOM3, S100M1A, and S100M3 operating mechanisms. Circuit breaker with a Spectra-Flex™ cable operator: Circuit breaker Flange mounted handle mechanism: 150 to 600 amps - STDA1 SK1200 - STDA3 Breaker mounted mechanism Operating cable | C-H Westinghouse | Type C361 disconnect switch: | Disconnect switch with an operating mechanism Operating handle: C361H1 or C361H3 In 24.13" deep enclosures, platform must be used with shaft (not included) | Type C371 circuit breaker operating mechanism with a C-H Westinghouse circuit breaker: | Circuit breaker Operating mechanism Long operating rod (if required) Operating handle: 150 amp - C371H1 or C371H3 250 through 600 amp - C371H5 or C371H7 | Flex-Shaft™ handle mechanism: | Circuit breaker Complete Flex-Shaft™ handle mechanism | General Electric | Disconnect switch: | Disconnect switch: Type QMR or QMW Fuse clip kit or no-fuse kit Flange handle: STDA1 or STDA2 Variable depth operating mechanism Extended length drive rod (if required) | Circuit breaker: | Circuit breaker Flange handle: STDA1 or STDA2 Variable depth operating mechanism Extended length drive rod (if required) An optional General Electric Flange Stiffener Kit (TDSR) is recommended when General Electric Type TDA devices are installed in 72.13" high enclosures with operating handle mounted on centerpost. Use with TDOM1, TDOM2, TDOM3, S100M1A, and S100M3 operating mechanisms. | Circuit breaker with a Spectra-Flex™ cable operator: | Circuit breaker Flange mounted handle mechanism: 150 to 600 amps - STDA1 SK1200 - STDA3 Breaker mounted mechanism Operating cable | I-T-E Siemens Disconnect switch: Basic switch (right-hand) Fuse or no-fuse kit Flange mounted handle: FHOHS Switch operator Operating cable: FHOEC036 cable for 12.13" deep FHOECO48 for 18.13" and 24.13" deep enclosures Circuit breaker: Circuit breaker Pressure wire connectors Flange mounted handle: 100 to 600 - FHOH 800 to 2000 - FHOHN Circuit breaker operator mechanism Operating cable: 36" cable for 12.13" or 18.13" deep 48" for 24.13" deep enclosures These items are available from Siemens I-T-E as a complete mechanism with a 36" operating cable only Order items separately when using a 48" cable Square D Disconnect switch: Disconnect switch with operating mechanism Universal handle mechanism: Type A-1 Long operating rod (if required) Circuit breaker: Circuit breaker Operating mechanism Universal handle mechanism: Type A-1 Long operating rod (if required) Class 9422 Type T disconnect switch with a cable mechanism: Disconnect switch with operating mechanism: Class 9422, Type T Handle mechanism: Class 9422, Type A-1 Cable mechanism: Class 9422 CFT_O, 3, 5, or 10 foot Circuit breaker with a cable mechanism: Circuit breaker: Square D Handle mechanism: Class 9422, type A-1 Cable mechanism: Class 9422 CFT_O, 3, 5, or 10 foot An optional Square D Channel flange Support Kit (9422-C1) is recommended when some Square D devices are installed in 72.13" high enclosures with operating handle mounted on centerpost. | I-T-E Siemens | Disconnect switch: | Basic switch (right-hand) Fuse or no-fuse kit Flange mounted handle: FHOHS Switch operator Operating cable: FHOEC036 cable for 12.13" deep FHOECO48 for 18.13" and 24.13" deep enclosures | Circuit breaker: | Circuit breaker Pressure wire connectors Flange mounted handle: 100 to 600 - FHOH 800 to 2000 - FHOHN Circuit breaker operator mechanism Operating cable: 36" cable for 12.13" or 18.13" deep 48" for 24.13" deep enclosures These items are available from Siemens I-T-E as a complete mechanism with a 36" operating cable only Order items separately when using a 48" cable | Square D | Disconnect switch: | Disconnect switch with operating mechanism Universal handle mechanism: Type A-1 Long operating rod (if required) | Circuit breaker: | Circuit breaker Operating mechanism Universal handle mechanism: Type A-1 Long operating rod (if required) | Class 9422 Type T disconnect switch with a cable mechanism: | Disconnect switch with operating mechanism: Class 9422, Type T Handle mechanism: Class 9422, Type A-1 Cable mechanism: Class 9422 CFT_O, 3, 5, or 10 foot | Circuit breaker with a cable mechanism: | Circuit breaker: Square D Handle mechanism: Class 9422, type A-1 Cable mechanism: Class 9422 CFT_O, 3, 5, or 10 foot An optional Square D Channel flange Support Kit (9422-C1) is recommended when some Square D devices are installed in 72.13" high enclosures with operating handle mounted on centerpost. | |||||||||||||||
| ABB Controls | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Disconnect switch: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Flange operated switch (fusible or non-fusible) Shaft: 12.13" deep enclosures use DSFHS-12 18.13" deep enclosures use DSFHS-17 24.13" deep enclosures, platform must be used with shaft (not included) Handle: DSFHN-HS12 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Circuit breaker: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Circuit breaker: ABB Operating mechanism Shaft: 12.13" deep enclosures use K7FHD-S12 18.13" deep enclosures use K7FHD-S17 24.13" deep enclosures, platform must be used with shaft (not included) Handle mechanism: K7FHD-HS12 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Allen Bradley | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Bulletin 1494F flange mounted disconnect switch: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Disconnect switch Fuse block adaptor (if required) Line and load connectors (if required) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1494D flange mounted circuit breaker operating mechanism, order: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Circuit breaker: C-H Westinghouse Operating mechanism Slide mechanism | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Bulletin 1494U flange mounted disconnect switch, order: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Disconnect switch Operating handle Connecting rod (long) Trailer fuse block kit (if required) Fuse kit (if required) Line and load connectors (if required) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Bulletin 1494U flange mounted circuit breaker operating mechanism, order: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Circuit breaker: C-H Westinghouse Operating mechanism Operating handle Connecting rod (long) When Allen Bradley 1494U devices are installed in 72" high enclosures with the operating handle mounted on the center post, an optional Allen Bradley channel support kit is recommended. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| C-H Westinghouse | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Type C361 disconnect switch: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Disconnect switch with an operating mechanism Operating handle: C361H1 or C361H3 In 24.13" deep enclosures, platform must be used with shaft (not included) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Type C371 circuit breaker operating mechanism with a C-H Westinghouse circuit breaker: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Circuit breaker Operating mechanism Long operating rod (if required) Operating handle: 150 amp - C371H1 or C371H3 250 through 600 amp - C371H5 or C371H7 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Flex-Shaft™ handle mechanism: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Circuit breaker Complete Flex-Shaft™ handle mechanism | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| General Electric | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Disconnect switch: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Disconnect switch: Type QMR or QMW Fuse clip kit or no-fuse kit Flange handle: STDA1 or STDA2 Variable depth operating mechanism Extended length drive rod (if required) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Circuit breaker: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Circuit breaker Flange handle: STDA1 or STDA2 Variable depth operating mechanism Extended length drive rod (if required) An optional General Electric Flange Stiffener Kit (TDSR) is recommended when General Electric Type TDA devices are installed in 72.13" high enclosures with operating handle mounted on centerpost. Use with TDOM1, TDOM2, TDOM3, S100M1A, and S100M3 operating mechanisms. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Circuit breaker with a Spectra-Flex™ cable operator: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Circuit breaker Flange mounted handle mechanism: 150 to 600 amps - STDA1 SK1200 - STDA3 Breaker mounted mechanism Operating cable | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| I-T-E Siemens | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Disconnect switch: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Basic switch (right-hand) Fuse or no-fuse kit Flange mounted handle: FHOHS Switch operator Operating cable: FHOEC036 cable for 12.13" deep FHOECO48 for 18.13" and 24.13" deep enclosures | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Circuit breaker: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Circuit breaker Pressure wire connectors Flange mounted handle: 100 to 600 - FHOH 800 to 2000 - FHOHN Circuit breaker operator mechanism Operating cable: 36" cable for 12.13" or 18.13" deep 48" for 24.13" deep enclosures These items are available from Siemens I-T-E as a complete mechanism with a 36" operating cable only Order items separately when using a 48" cable | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Square D | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Disconnect switch: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Disconnect switch with operating mechanism Universal handle mechanism: Type A-1 Long operating rod (if required) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Circuit breaker: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Circuit breaker Operating mechanism Universal handle mechanism: Type A-1 Long operating rod (if required) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Class 9422 Type T disconnect switch with a cable mechanism: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Disconnect switch with operating mechanism: Class 9422, Type T Handle mechanism: Class 9422, Type A-1 Cable mechanism: Class 9422 CFT_O, 3, 5, or 10 foot | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Circuit breaker with a cable mechanism: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Circuit breaker: Square D Handle mechanism: Class 9422, type A-1 Cable mechanism: Class 9422 CFT_O, 3, 5, or 10 foot An optional Square D Channel flange Support Kit (9422-C1) is recommended when some Square D devices are installed in 72.13" high enclosures with operating handle mounted on centerpost. |
2UD, 2UDF & 2UDCP
| col1 |
|---|
| ABB Controls |
| Disconnect switch: |
| Flange operated switch (fusible or non-fusible) Shaft: 12.13" deep enclosures use DSFHS-12 18.13" deep enclosures use DSFHS-17 24.13" deep enclosures, platform must be used with shaft (not included) Handle: DSFHN-HS12 |
| Circuit breaker: |
| Circuit breaker: ABB Operating mechanism Shaft: 12.13" deep enclosures use K7FHD-S12 18.13" deep enclosures use K7FHD-S17 24.13" deep enclosures, platform must be used with shaft (not included) Handle mechanism: K7FHD-HS12 |
| Allen Bradley |
| Bulletin 1494F flange mounted disconnect switch: |
| Disconnect switch Fuse block adaptor (if required) Line and load connectors (if required) |
| 1494D flange mounted circuit breaker operating mechanism, order: |
| Circuit breaker: C-H Westinghouse Operating mechanism Slide mechanism |
| Bulletin 1494U flange mounted disconnect switch, order: |
| Disconnect switch Operating handle Connecting rod (long) Trailer fuse block kit (if required) Fuse kit (if required) Line and load connectors (if required) |
| Bulletin 1494U flange mounted circuit breaker operating mechanism, order: |
| Circuit breaker: C-H Westinghouse Operating mechanism Operating handle Connecting rod (long) When Allen Bradley 1494U devices are installed in 72" high enclosures with the operating handle mounted on the center post, an optional Allen Bradley channel support kit is recommended. |
2UD, 2UDF & 2UDCP
| col1 |
|---|
| C-H Westinghouse |
| Type C361 disconnect switch: |
| Disconnect switch with an operating mechanism Operating handle: C361H1 or C361H3 In 24.13" deep enclosures, platform must be used with shaft (not included) |
| Type C371 circuit breaker operating mechanism with a C-H Westinghouse circuit breaker: |
| Circuit breaker Operating mechanism Long operating rod (if required) Operating handle: 150 amp - C371H1 or C371H3 250 through 600 amp - C371H5 or C371H7 |
| Flex-Shaft™ handle mechanism: |
| Circuit breaker Complete Flex-Shaft™ handle mechanism |
| General Electric |
| Disconnect switch: |
| Disconnect switch: Type QMR or QMW Fuse clip kit or no-fuse kit Flange handle: STDA1 or STDA2 Variable depth operating mechanism Extended length drive rod (if required) |
| Circuit breaker: |
| Circuit breaker Flange handle: STDA1 or STDA2 Variable depth operating mechanism Extended length drive rod (if required) An optional General Electric Flange Stiffener Kit (TDSR) is recommended when General Electric Type TDA devices are installed in 72.13" high enclosures with operating handle mounted on centerpost. Use with TDOM1, TDOM2, TDOM3, S100M1A, and S100M3 operating mechanisms. |
| Circuit breaker with a Spectra-Flex™ cable operator: |
| Circuit breaker Flange mounted handle mechanism: 150 to 600 amps - STDA1 SK1200 - STDA3 Breaker mounted mechanism Operating cable |
2UD, 2UDF & 2UDCP
| col1 |
|---|
| I-T-E Siemens |
| Disconnect switch: |
| Basic switch (right-hand) Fuse or no-fuse kit Flange mounted handle: FHOHS Switch operator Operating cable: FHOEC036 cable for 12.13" deep FHOECO48 for 18.13" and 24.13" deep enclosures |
| Circuit breaker: |
| Circuit breaker Pressure wire connectors Flange mounted handle: 100 to 600 - FHOH 800 to 2000 - FHOHN Circuit breaker operator mechanism Operating cable: 36" cable for 12.13" or 18.13" deep 48" for 24.13" deep enclosures These items are available from Siemens I-T-E as a complete mechanism with a 36" operating cable only Order items separately when using a 48" cable |
| Square D |
| Disconnect switch: |
| Disconnect switch with operating mechanism Universal handle mechanism: Type A-1 Long operating rod (if required) |
| Circuit breaker: |
| Circuit breaker Operating mechanism Universal handle mechanism: Type A-1 Long operating rod (if required) |
| Class 9422 Type T disconnect switch with a cable mechanism: |
| Disconnect switch with operating mechanism: Class 9422, Type T Handle mechanism: Class 9422, Type A-1 Cable mechanism: Class 9422 CFT_O, 3, 5, or 10 foot |
| Circuit breaker with a cable mechanism: |
| Circuit breaker: Square D Handle mechanism: Class 9422, type A-1 Cable mechanism: Class 9422 CFT_O, 3, 5, or 10 foot An optional Square D Channel flange Support Kit (9422-C1) is recommended when some Square D devices are installed in 72.13" high enclosures with operating handle mounted on centerpost. |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 | col6 | col7 | col8 | col9 | col10 | col11 |
|---|---|---|---|---|---|---|---|---|---|---|
| Fits Enclosure Height | Fits Enclosure Height | ABB Switch Number | Amp | Space Occupied | When A=60.13 P | When A=72.13 P | ||||
| 60.13 | 72.13 | ABB Switch Number | Rating | Fuse Clip | Fuse Class | L | M | N | When A=60.13 P | When A=72.13 P |
| • | • | OETL-NF30-F | 30A | No Fuse | — | 4.45 | 3.91 | 0.25 | 9.53 | 15.53 |
| • | • | OETL-NF60-F | 60A | No Fuse | — | 4.86 | 3.91 | 0.25 | 9.34 | 15.34 |
| • | • | OETL-NF100-F | 100A | No Fuse | — | 4.86 | 4.91 | 0.25 | 8.78 | 14.78 |
| • | • | OETL-NF175-F | 175A | No Fuse | — | 7.30 | 6.62 | 0.25 | 6.53 | 12.53 |
| • | • | OETL-NF200-F | 200A | No Fuse | — | 7.36 | 7.41 | 0.25 | 6.53 | 12.53 |
| • | • | OESA-F30J6-F | 30A | 30A-600V | J | 4.28 | 6.70 | 0.25 | 7.85 | 13.86 |
| • | • | OESA-F60J6-F | 60A | 60A-600V | J | 4.28 | 6.39 | 0.25 | 7.85 | 13.86 |
| • | • | OESA-F100J6-F | 100A | 100A-600V | J¹ | 6.54 | 7.78 | 0.25 | 7.42 | 13.42 |
| 200A² |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 | col6 | col7 | col8 | col9 | col10 | col11 |
|---|---|---|---|---|---|---|---|---|---|---|
| Fits Enclosure Height | Fits Enclosure Height | ISOMAX Circuit Breaker | Amp Rating | Operating Mechanism | Frame Type | Space Occupied | Space Occupied | When A=60.13 P | When A=72.13 P | |
| 60.13 | 72.13 | ISOMAX Circuit Breaker | Amp Rating | Operating Mechanism | Frame Type | L | M | N | When A=60.13 P | When A=72.13 P |
| • | • | S1N100TL | 100A | K2FHD-M | S1 | 5.30 | 4.60 | 0.63 | 8.33 | 14.33 |
| • | • | S3N150TW | 150A | K3FHD-M | S3 | 6.67 | 5.02 | 0.63 | 7.73 | 13.73 |
| • | • | S3N225TW | 225A | K3FHD-M | S3 | 6.67 | 5.02 | 0.63 | 7.73 | 13.73 |
| • | • | S4N250BW | 250A | K4FHD-M | S4 | 8.45 | 5.02 | 0.63 | 6.20 | 12.20 |
| • | • | S5N400TW | 400A | K5FHD-M | S5 | 8.45 | 6.40 | 0.63 | 6.20 | 12.20 |
| • | • | S6N600TW | 600A | K6FHD-M | S6 | 8.33 | 10.00 | 0.63 | 5.53 | 11.53 |
| • | • | S6N800TW | 800A | K6FHD-M | S6 | 8.33 | 10.00 | 0.63 | 5.53 | 11.53 |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 | col6 | col7 | col8 | col9 | col10 | col11 |
|---|---|---|---|---|---|---|---|---|---|---|
| Fits Enclosure Height | Fits Enclosure Height | Allen Bradley Switch Number | Amp Rating | Space Occupied M¹ | When A=60.13 P | When A=72.13 P | ||||
| 60.13 | 72.13 | Allen Bradley Switch Number | Amp Rating | Fuse Clip | Fuse Class | L | Space Occupied M¹ | N | When A=60.13 P | When A=72.13 P |
| • | • | N30 | 30A | No Fuse | — | 4.62 | 6.50 | 0.63 | 5.31 | 11.31 |
| • | • | NF30 | 30A | 30A-250V | H, K, R | 6.50 | 6.50 | 0.63 | 5.31 | 11.31 |
| • | • | NF30 | 30A | 60A-250V | H, K, R | 7.25 | 6.50 | 0.63 | 5.31 | 11.31 |
| • | • | NF30 | 30A | 30A-600V | H, K, R | 9.25 | 6.50 | 0.63 | 5.31 | 11.31 |
| • | • | NF30 | 30A | 60A-600V | H, K, R | 9.75 | 6.50 | 0.63 | 5.31 | 11.31 |
| • | • | NF30 | 30A | 30A-600V | J | 6.50 | 6.50 | 0.63 | 5.31 | 11.31 |
| • | • | NF30 | 30A | 60A-600V | J | 6.62 | 6.50 | 0.63 | 5.31 | 11.31 |
| • | • | N60 | 60A | No Fuse | — | 4.62 | 6.50 | 0.63 | 4.62 | 10.62 |
| • | • | NF60 | 60A | 30A-600V | H, K, R | 10.38 | 6.50 | 0.63 | 4.62 | 10.62 |
| • | • | NF60 | 60A | 60A-250V | H, K, R | 8.38 | 6.50 | 0.63 | 4.62 | 10.62 |
| • | • | NF60 | 60A | 100A-250V | H, K, R | 10.88 | 6.50 | 0.63 | 4.62 | 10.62 |
| • | • | NF60 | 60A | 60A-600V | H, K, R | 10.88 | 6.50 | 0.63 | 4.62 | 10.62 |
| • | • | NF60 | 60A | 100A-600V | H, K, R | 12.88 | 6.62 | 0.63 | 4.62 | 10.62 |
| • | • | NF60 | 60A | 60A-600V | J | 7.75 | 6.50 | 0.63 | 4.62 | 10.62 |
| • | • | NF60 | 60A | 100A-600V | J | 9.75 | 6.50 | 0.63 | 4.62 | 10.62 |
| • | N100 | 100A | No Fuse | — | 4.62 | 7.25 | 0.63 | — | 8.75 | |
| • | NF100 | 100A | 100A-250V | H, K, R | 11.38 | 7.38 | 0.63 | — | 8.75 | |
| • | NF100 | 100A | 200A-250V | H, K, R | 12.25 | 7.62 | 0.63 | — | 8.75 | |
| • | NF100 | 100A | 100A-600V | H, K, R | 13.38 | 7.50 | 0.63 | — | 8.75 | |
| • | NF100 | 100A | 200A-600V | H, K, R | 14.75 | 7.75 | 0.63 | — | 8.75 | |
| • | NF100 | 100A | 100A-600V | J | 10.12 | 7.38 | 0.63 | — | 8.75 | |
| • | NF100 | 100A | 200A-600V | J | 10.88 | 7.50 | 0.63 | — | 8.75 | |
| • | N200 | 200A | No Fuse | — | 7.12 | 10.38 | 0.56 | — | 7.13 | |
| • | NF200 | 200A | 200A-250V | H, K, R | 15.00 | 10.38 | 0.56 | — | 7.13 | |
| • | NF200 | 200A | 400A-250V | H, K, R | 16.56 | 10.75 | 0.56 | — | 7.13 | |
| • | NF200 | 200A | 200A-600V | H, K, R | 17.56 | 10.38 | 0.56 | — | 7.13 | |
| • | NF200 | 200A | 400A-600V | H, K, R | 19.56 | 11.00 | 0.56 | — | 7.13 | |
| • | NF200 | 200A | 200A-600V | J | 13.69 | 10.38 | 0.56 | — | 7.13 | |
| • | NF200 | 200A | 400A-600V | J | 15.00 | 10.62 | 0.56 | — | 7.13 |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 | col6 | col7 | col8 | col9 | col10 |
|---|---|---|---|---|---|---|---|---|---|
| Fits Enclosure Height | Fits Enclosure Height | Alan Bradley Type Number | Amp Rating | Circuit Breker Type | Space Occupied | When A=60.13 P | When A=72.13 P | ||
| 60.13 | 72.13 | Alan Bradley Type Number | Amp Rating | Circuit Breker Type | L | M¹ | N | When A=60.13 P | When A=72.13 P |
| • | • | N4/N40 | 150A | C-H Westinghouse EHD,FD,FDB,FDC,HFD,HMCP | 5.81 | 4.56 | 0.63 | 5.25 | 11.25 |
| • | • | N5/N55 | 225A | General Electric TFK, THFK, TFC | 8.81 | 4.75 | 0.63 | 4.44 | 10.44 |
| • | • | N5/N50 | 250A | C-H Westinghouse JD,JDB,JDC,HJD,HMCP | 8.81 | 4.75 | 0.63 | 4.44 | 10.44 |
| • | N5/N60 | 400A | C-H Westinghouse KD,KDB,DK,HKD,HMCP | 8.81 | 5.88 | 0.63 | — | 10.50 |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 | col6 | col7 | col8 | col9 | col10 | col11 |
|---|---|---|---|---|---|---|---|---|---|---|
| Fits Enclosure Height | Fits Enclosure Height | Alan Bradley Switch Number | Amp | Space Occupied | When A=60.13 P | When A=72.13 P | ||||
| 60.13 | 72.13 | Alan Bradley Switch Number | Rating | Fuse Clip | Fuse Class | L | M² | N | When A=60.13 P | When A=72.13 P |
| • | • | DS30 | 30A | No Fuse | — | 3.88 | 6.75 | 1.06 | 6.00 | 12.00 |
| • | • | DS30 | 30A | 30A-250V | H,K,R | 5.25 | 6.75 | 1.06 | 6.00 | 12.00 |
| • | • | DS30 | 30A | 30A-600V | H,K,R | 8.00 | 6.75 | 1.06 | 6.00 | 12.00 |
| • | • | DS30 | 30A | 30A-600V | J | 5.25 | 6.75 | 1.06 | 6.00 | 12.00 |
| • | • | DS30 | 30A | 60A-250V | H,K | 6.00 | 6.75 | 1.06 | 6.00 | 12.00 |
| • | • | DS30 | 30A | 60A-600V | H,K | 8.50 | 6.75 | 1.06 | 6.00 | 12.00 |
| • | • | DS30 | 30A | 60A-600V | J | 5.38 | 6.75 | 1.06 | 6.00 | 12.00 |
| • | • | DS60 | 60A | No Fuse | — | 3.88 | 6.75 | 1.06 | 5.81 | 11.81 |
| • | • | DS60 | 60A | 60A-250V | H,K,R | 6.00 | 6.75 | 1.06 | 5.81 | 11.81 |
| • | • | DS60 | 60A | 60A-600V | H,K,R | 8.50 | 6.75 | 1.06 | 5.81 | 11.81 |
| • | • | DS60 | 60A | 60A-600V | J | 5.38 | 6.75 | 1.06 | 5.81 | 11.81 |
| • | • | DS60 | 60A | 30A-600V | H,K,R | 8.00 | 6.75 | 1.06 | 5.81 | 11.81 |
| • | • | DS60 | 60A | 100A-250V | H,K | 8.50 | 6.75 | 1.06 | 5.81 | 11.81 |
| • | • | DS60 | 60A | 100A-600V | H,K | 10.50 | 6.75 | 1.06 | 5.81 | 11.81 |
| • | • | DS60 | 60A | 100A-600V | J | 7.25 | 6.75 | 1.06 | 5.81 | 11.81 |
| • | • | DS100¹ | 100A | No Fuse | — | 3.88 | 6.75 | 1.06 | 5.81 | 11.81 |
| • | • | DS100¹ | 100A | 100A-250V | H,K,R | 8.12 | 6.75 | 1.06 | 5.81 | 11.81 |
| • | • | DS100¹ | 100A | 100A-600V | H,K,R | 10.12 | 6.75 | 1.06 | 5.81 | 11.81 |
| • | • | DS100¹ | 100A | 100A-600V | J | 6.80 | 6.75 | 1.06 | 5.81 | 11.81 |
| • | • | DS100¹ | 100A | 60A-600V | H,K,R | 10.12 | 6.75 | 1.06 | 5.81 | 11.81 |
| • | • | DS100¹ | 100A | 60A-600V | J | 8.88 | 6.75 | 1.06 | 5.81 | 11.81 |
| • | DS2001 | 200A | No Fuse | — | 4.75 | 8.00 | 1.06 | — | 10.34 | |
| • | DS2001 | 200A | 200A-250V | H,K,R | 10.88 | 8.00 | 1.06 | — | 10.34 | |
| • | DS2001 | 200A | 200A-600V | H,K,R | 13.88 | 8.00 | 1.06 | — | 10.34 | |
| • | DS2001 | 200A | 200A-600V | J | 9.50 | 8.00 | 1.06 | — | 10.34 | |
| • | DS2001 | 200A | 100A-600V | H,K,R | 12.00 | 8.00 | 1.06 | — | 10.34 | |
| • | DS2001 | 200A | 100A-600V | J | 8.75 | 8.00 | 1.06 | — | 10.34 |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 | col6 | col7 | col8 | col9 | col10 |
|---|---|---|---|---|---|---|---|---|---|
| Fits Enclosure Height | Fits Enclosure Height | Alan Bradley Type Number | Amp | Space Occupied | When A=60.13 P | When A=72.13 P | |||
| 60.13 | 72.13 | Alan Bradley Type Number | Rating | Circuit Breker Type | L | M1 | N | When A=60.13 P | When A=72.13 P |
| • | • | M40 | 15A-150A | C-H Westinghouse EHD,FD,FDB,FDC,HFD,HMCP | 5.00 | 4.62 | 1.06 | 7.25 | 13.25 |
| • | • | M50 | 70A-250A | C-H Westinghouse JD,JDB,JDC,HJD,HMCP | 9.75 | 4.88 | 1.06 | 6.81 | 12.81 |
| • | M60 | 100A-400A | C-H Westinghouse KD,KDB,DK,HKD,HMCP | 9.69 | 6.25 | 1.06 | — | 12.62 |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 | col6 | col7 | col8 | col9 | col10 | col11 |
|---|---|---|---|---|---|---|---|---|---|---|
| Fits Enclosure Height | Fits Enclosure Height | Cutler Hammer Type Number | Amp | Space Occupied | When A=60.13 P | When A=72.13 P | ||||
| 60.13 | 72.13 | Cutler Hammer Type Number | Rating | Fuse Clip | Fuse Class | L | M | N | When A=60.13 P | When A=72.13 P |
| • | • | C361NC | 30A | No Fuse | — | 5.75 | 7.55 | 0.63 | 6.50 | 12.50 |
| • | • | C361SC21 | 30A | 30A-250V | H, K, R | 8.38 | 7.55 | 0.63 | 6.50 | 12.50 |
| • | • | C361SC61 | 30A | 60A-250V | H, K, R | 8.38 | 7.55 | 0.63 | 6.50 | 12.50 |
| • | • | C361SC61 | 30A | 30A-600V | H, J, K, R | 8.38 | 7.55 | 0.63 | 6.50 | 12.50 |
| • | • | C361ND | 60A | No Fuse | — | 5.75 | 7.55 | 0.63 | 6.50 | 12.50 |
| • | • | C361SD22 | 60A | 60A-250V | H, K, R | 8.38 | 7.55 | 0.63 | 6.50 | 12.50 |
| • | • | C361SD22 | 60A | 30A-600V | J | 8.38 | 7.55 | 0.63 | 6.50 | 12.50 |
| • | • | C361SD62 | 60A | 60A-600V | H, K, R | 8.38 | 7.55 | 0.63 | 6.50 | 12.50 |
| • | • | C361SD62 | 60A | 60A-600V | J | 8.38 | 7.55 | 0.63 | 6.50 | 12.50 |
| • | • | C361NE | 100A | No Fuse | — | 5.56 | 9.07 | 0.63 | 6.06 | 12.06 |
| • | • | C361SE263 | 100A | 100A-250V | H, K, R | 10.31 | 9.07 | 0.63 | 6.06 | 12.06 |
| • | • | C361SE263 | 100A | 100A-600V | H, K, R | 10.31 | 9.07 | 0.63 | 6.06 | 12.06 |
| • | • | C361SE263 | 100A | 100A-600V | J | 10.31 | 9.07 | 0.63 | 6.06 | 12.06 |
| • | • | C361NF | 200A | No Fuse | — | 13.06 | 10.12 | 0.63 | 4.06 | 10.12 |
| • | • | C361SF264 | 200A | 200A-250V | H, K, R | 13.06 | 10.12 | 0.63 | 4.06 | 10.12 |
| • | • | C361SF264 | 200A | 200A-600V | H, K, R, J | 13.06 | 10.12 | 0.63 | 4.06 | 10.12 |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 | col6 | col7 | col8 | col9 | col10 |
|---|---|---|---|---|---|---|---|---|---|
| Fits Enclosure Height | Fits Enclosure Height | Cutler Hammer Mechanisms | Amp | Space Occupied | When A=60.13 P | When A=72.13 P | |||
| 60.13 | 72.13 | Cutler Hammer Mechanisms | Rating | Frame Type | L | M | N | When A=60.13 P | When A=72.13 P |
| • | • | C371E | 150A | F Frame EHD,FDB,FD,HFD,FDC | 6.00 | 5.62 | 0.63 | 7.62 | 13.62 |
| • | • | C371E | 150A | F Frame HMCP | 6.00 | 5.62 | 0.63 | 7.62 | 13.62 |
| ¹ | • | C371F | 250A | J Frame JDB,JD,HJD,JDC | 8.94 | 8.12 | 0.63 | 7.50 | 13.50 |
| ¹ | • | C371F | 250A | J Frame HMCP | 10.94 | 8.12 | 0.63 | 7.50 | 13.50 |
| ¹ | • | C371F | 400A | K Frame DK,KDB,KD,HKD | 9.75 | 8.12 | 0.63 | 7.00 | 13.00 |
| ¹ | • | C371F | 400A | K Frame HMCP | 9.75 | 8.12 | 0.63 | 7.00 | 13.00 |
| ² | C371G | 600A | L Frame LD,HLD,LDC | 8.44 | 12.00 | 0.63 | - | 11.38 | |
| ² | C371G | 600A | L Frame HMCP | 8.44 | 12.00 | 0.63 | - | 11.38 |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 |
|---|---|---|---|---|
| Complete Operator | Breaker Height "X" | Breaker Width "Y" | ||
| Mechanisms | Amp Rating | Frame Type | (in inches) | (in inches) |
| F1S03 | 150A | F Frame EHD,FDB,FD,HFD | 6.00 | 4.12 |
| F1S03 | 150A | F Frame HCMP | 6.00 | 4.12 |
| F2S03 | 250A | J Frame JDB,JD,HJD,JDC | 10.00 | 4.12 |
| F2S03 | 250A | J Frame HCMP | 10.00 | 4.12 |
| F3S03 | 400A | K Frame DK,KDB,KD,HKD | 10.12 | 5.50 |
| F3S03 | 400A | K Frame HCMP | 12.45 | 5.50 |
| F4S04 | 600A | L Frame LD,HLD,LDC | 10.75 | 8.25 |
| F7S04 | 800A | M Frame MD,MDS | 16.00 | 8.25 |
| F5S04 | 1200A | N Frame ND,HND,NDC | 16.00 | 8.25 |
| F6S04 | 2500A | R Frame RD,CRD, RDC | 16.00 | 15.50 |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 | col6 | col7 | col8 | col9 | col10 | col11 |
|---|---|---|---|---|---|---|---|---|---|---|
| Fits Enclosure Height | Fits Enclosure Height | General Electric Switch Mechanisms | Amp Rating | Space Occupied M | When A=60.13 P | When A=72.13 P | ||||
| 60.13 | 72.13 | General Electric Switch Mechanisms | Amp Rating | Fuse Clip | Fuse Class | L | Space Occupied M | N | When A=60.13 P | When A=72.13 P |
| • | • | TDOM1A | 30A | No Fuse | - | 6.88 | 5.38 | 0.63 | 8.38 | 14.38 |
| • | • | TDOM1A | 30A | 30A-250V | H, R | 6.88 | 5.38 | 0.63 | 8.38 | 14.38 |
| • | • | TDOM1B | 30A | 30A-600V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
| • | • | TDOM1B | 30A | 60A-250V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
| • | • | TDOM1B | 30A | 60A-600V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
| • | • | TDOM1A | 60A | No Fuse | - | 6.88 | 5.38 | 0.63 | 8.38 | 14.38 |
| • | • | TDOM1B | 60A | 60A-250V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
| • | • | TDOM1B | 60A | 60A-600V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
| • | • | TDOM1B | 60A | 100A-250V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
| • | • | TDOM1B | 60A | 100A-600V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
| • | • | TDOM1A | 100A | No Fuse | - | 6.88 | 5.38 | 0.63 | 8.38 | 14.38 |
| • | • | TDOM1B | 100A | 100A-250V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
| • | • | TDOM1B | 100A | 100A-600V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
| • | • | TDOM1B | 100A | 200A-250V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
| • | • | TDOM1B | 100A | 200A-600V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
| • | • | TDOM2 | 200A | No Fuse | - | 7 | 9.25 | 0.63 | 5.69 | 11.69 |
| • | • | TDOM2 | 200A | 200A-250V | H, R | 15.38 | 9.25 | 0.63 | 5.69 | 11.69 |
| • | • | TDOM2 | 200A | 200A-600V | H, R | 15.38 | 9.25 | 0.63 | 5.69 | 11.69 |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 | col6 | col7 | col8 | col9 | col10 |
|---|---|---|---|---|---|---|---|---|---|
| Fits Enclosure Height | Fits Enclosure Height | General Electric Circuit Breaker Mechanisms | Amp Rating | Frame Type | Space Occupied | Space Occupied | When A=60.13 P | When A=72.13 P | |
| 60.13 | 72.13 | General Electric Circuit Breaker Mechanisms | Amp Rating | Frame Type | L | M | N | When A=60.13 P | When A=72.13 P |
| • | • | TDOM1A | 150A | TEB, TED, THED | 6.88 | 5.38 | 0.63 | 7.24 | 13.24 |
| • | • | TDOM1A | 150A | TEC | 6.88 | 5.38 | 0.63 | 7.24 | 13.24 |
| • | • | TDOM1B | 150A | TB1 | 11.50 | 5.38 | 0.63 | 7.24 | 13.24 |
| • | • | TDOM1B | 150A | TEC, TECL | 11.50 | 5.38 | 0.63 | 7.24 | 13.24 |
| • | • | TDOM1C | 150A | TEL | 6.88 | 5.38 | 0.63 | 7.24 | 13.24 |
| • | • | TDOM1D | 150A | THLC1 | 6.88 | 5.38 | 0.63 | 5.87 | 11.87 |
| • | • | TDOM3 | 225A | TFJ | 10.38 | 5.88 | 0.63 | 6.81 | 12.81 |
| • | • | TDOM3 | 225A | TFK, THFK, TFL | 10.38 | 5.88 | 0.63 | 6.81 | 12.81 |
| • | TDOM4 | 400A | TJJ, TJK4, THJK4, TJL4V | 8.25 | 9.50 | 0.63 | — | 11.91 | |
| • | TDOM4 | 600A | TJK6, THJK6, TJ4V, TJL4V | 8.25 | 9.50 | 0.63 | — | 11.91 | |
| • | TDOM5 | 400A | TB4, TJH6S | 14.25 | 9.50 | 0.63 | — | 11.91 | |
| • | TDOM6 | 225A | TLB2, THLC2 | 11.75 | 9.50 | 0.63 | — | 11.35 | |
| • | TDOM6 | 400A | TLB4, THLC4 | 11.75 | 9.50 | 0.63 | — | 9.97 | |
| • | • | SDOM1A | 150A | SE150 | 6.88 | 5.38 | 0.63 | 7.24 | 13.24 |
| • | • | SDOM3 | 250A | SPECTRA SF250 | 10.38 | 5.88 | 0.63 | 6.81 | 11.88 |
| • | SDOM4 | 600A | SPECTRA SG600 | 10.00 | 7.12 | 0.63 | — | 9.18 |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 | col6 |
|---|---|---|---|---|---|
| Fits Enclosure Height | Fits Enclosure Height | Circuit Breaker Height | Circuit Breaker Width | ||
| 60.13 | 72.13 | Frame Size | Max Amp Rating | "X" | "Y" |
| • | • | E150 | 150A | 6.31 | 4.12 |
| • | • | SE150 | 150A | 6.31 | 4.12 |
| • | • | SF250 | 250A | 10.12 | 4.12 |
| • | • | SG600 | 600A | 10.09 | 5.50 |
| • | • | SK1200 | 1200A | 15.50 | 8.25 |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 |
|---|---|---|---|
| Frame Size | Breaker Mechanism | Flange Mounting Handle¹ | Operating Cable² |
| E150 | SCOM1A | SCH1 | SC3L |
| SE150/SF250 | SCOM1EF | SCH1 | SC3L |
| SG600 | SCOM1G | SCH1 | SC3L |
| SK1200 | SCOM1K | SCH2K | SC3H |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 | col6 | col7 | col8 |
|---|---|---|---|---|---|---|---|
| Fits Enclosure Depth | Fits Enclosure Depth | Amp | Disconnect Height "X" | Disconnect Width "Y" | |||
| 60.13 | 72.13 | Switch | Rating | Fuse Clip | Fuse Class | Disconnect Height "X" | Disconnect Width "Y" |
| • | • | MCS603R | 30A | No Fuse | — | 5.52 | 6.13 |
| • | • | MCS603R | 30A | 30A-250V | H,K,R | 8.11 | 6.13 |
| • | • | MCS603R | 30A | 30A-600V | H,K,R | 10.11 | 6.13 |
| • | • | MCS603R | 30A | 30A-600V | J | 8.48 | 6.13 |
| • | • | MCS606R | 60A | No Fuse | — | 5.52 | 6.13 |
| • | • | MCS606R | 60A | 60A-250V | H,K,R | 7.86 | 6.13 |
| • | • | MCS606R | 60A | 60A-600V | H,K,R | 10.38 | 6.13 |
| • | • | MCS606R | 60A | 60A-600V | J | 8.36 | 6.13 |
| • | • | MCS610R | 100A | No Fuse | — | 7.59 | 7.38 |
| • | • | MCS610R | 100A | 100A-250V | H,K,R | 11.85 | 7.38 |
| • | • | MCS610R | 100A | 100A-600V | H,K,R | 13.85 | 7.38 |
| • | • | MCS610R | 100A | 100A-600V | J | 10.60 | 7.38 |
| • | • | MCS620R | 200A | No Fuse | — | 9.00 | 9.17 |
| • | • | MCS620R | 200A | 200A-250V | H,K,R | 14.70 | 9.17 |
| • | • | MCS620R | 200A | 200A-600V | H,K,R | 17.20 | 9.17 |
| • | • | MCS620R | 200A | 200A-600V | J | 13.32 | 9.17 |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 | col6 |
|---|---|---|---|---|---|
| Complete Operator Mechansim | Amp Rating | Breaker Frame Size | Circuit Breaker Height "X" | Circuit Breaker Width "Y" | |
| Complete Operator Mechansim | Amp Rating | Breaker Frame Size | Circuit Breaker Type | Circuit Breaker Height "X" | Circuit Breaker Width "Y" |
| FHOE036 | 125A | ED | ED2, ED4, ED6, HED4, HED6 | 6.34 | 3.00 |
| FHOE036 | 125A | CED | CED6 | 9.58 | 3.00 |
| FHOF036 | 250A | FD | FXD6-A, FD6-A, HFD6, FXD6ETJ, HHFD6, HHFXD6 | 9.50 | 4.50 |
| FHOF036 | 250A | CFD | CFD6, CFD6-ETI | 14.25 | 4.50 |
| FHOJ036 | 400A, 600A | JD, LD | JXD2, LXD6, JD6, LD6, HJD6, HLD6, HHJD6, HHLD6, HHJXD6, HHLDX6, JXD6-ETI, LXD6-ETI | 11.00 | 7.50 |
| FHOJ036 | 400A, 600A | CJD,CLD | CJD6, CLD6, CJD6-ETI, CLD6-ETI | 17.86 | 7.50 |
| FHOLMO36 | 800A | LMD | LMD6, LMXD6, HLMD6, HLMXD6, LMXD6-ETI | 16.00 | 9.00 |
| FHON048 | 800A, 1200A | MD, ND | MD6, ND6, MXD6, NXD6, HMD6, HND6, HMXD6, HNXD6, CMD6, CND6, MXD6-ETI, CMD6-ETI | 24.00 | 9.00 |
| FHONO48 | 1600A, 2000A | PD,RD | PD6, RD6, PXD6, RXD6, HPD6, HRD6, HPXD6, HRXD6, CPD6 | 24.50(2) | 13.63(2) |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 | col6 | col7 | col8 | col9 | col10 | col11 |
|---|---|---|---|---|---|---|---|---|---|---|
| Fits Enclosure Height | Fits Enclosure Height | Square D Amp Number | Amp Rating | Space Occupied | Space Occupied | When A=60.13 P | When A=72.13 P | |||
| 60.13 | 72.13 | Square D Amp Number | Amp Rating | Fuse Clip | Fuse Class | L | M | N | When A=60.13 P | When A=72.13 P |
| • | • | TCN-30 | 30A | No Fuse | — | 3.80 | 6.97 | 0.63 | 6.75 | 12.75 |
| • | • | TCF-30 | 30A | 30A-250V | H, K, R | 5.53 | 6.97 | 0.63 | 6.75 | 12.75 |
| • | • | TCF-33 | 30A | 30A-600V | H, K, R | 8.15 | 6.97 | 0.63 | 6.75 | 12.75 |
| • | • | TCF-33 | 30A | 60A-250V | H, K, R | 6.15 | 6.97 | 0.63 | 6.75 | 12.75 |
| • | • | TCF-33 | 30A | 30A-600V | J | 5.53 | 6.97 | 0.63 | 6.75 | 12.75 |
| • | • | TDN-60 | 60A | No Fuse | — | 3.80 | 6.97 | 0.63 | 6.75 | 12.75 |
| • | • | TDF-60 | 60A | 30A-600V | H, K, R | 8.15 | 6.97 | 0.63 | 6.75 | 12.75 |
| • | • | TDF-60 | 60A | 60A-250V | H, K, R | 6.15 | 6.97 | 0.63 | 6.75 | 12.75 |
| • | • | TDF-63 | 60A | 60A-600V | H, K, R | 8.65 | 6.97 | 0.63 | 6.75 | 12.75 |
| • | • | TDF-63 | 60A | 60A-600V | J | 5.53 | 6.97 | 0.63 | 6.75 | 12.75 |
| • | • | TEN-10 | 100A | No Fuse | — | 3.80 | 6.97 | 0.63 | 6.62 | 12.62 |
| • | • | TEF-10 | 100A | 100A-250V | H, K, R | 8.25 | 6.97 | 0.63 | 6.62 | 12.62 |
| • | • | TEF-10 | 100A | 100A-600V | H, K, R | 10.25 | 6.97 | 0.63 | 6.62 | 12.62 |
| • | • | TEF-10 | 100A | 100A-600V | J | 7.05 | 6.97 | 0.63 | 6.62 | 12.62 |
| • | • | TEF-13 | 100A | 200A-600V | J | — | — | 0.63 | 6.62 | 12.62 |
| • | • | TC-1 | 30A | No Fuse | ‑ | 5.75 | 6.12 | 0.63 | 5.88 | 11.88 |
| • | • | TC-2 | 30A | 30A-250V | H, K, R | 5.75 | 6.12 | 0.63 | 5.88 | 11.88 |
| • | • | TC-3 | 30A | 30A-600V | H, K, R | 7.75 | 6.12 | 0.63 | 5.88 | 11.88 |
| • | • | TC-3 | 30A | 60A-250V | H, K, R | 5.88 | 6.12 | 0.63 | 5.88 | 11.88 |
| • | • | TC-3 | 30A | 30A-600V | J | 5.75 | 6.12 | 0.63 | 5.88 | 11.88 |
| • | • | TD-1 | 60A | No Fuse | — | 6.38 | 6.75 | 0.63 | 6.75 | 12.75 |
| • | • | TD-2 | 60A | 30A-600V | H, K, R | 8.50 | 6.75 | 0.63 | 6.75 | 12.75 |
| • | • | TD-2 | 60A | 60A-250V | H, K, R | 6.50 | 6.75 | 0.63 | 6.75 | 12.75 |
| • | • | TD-3 | 60A | 60A-600V | H, K, R | 9.00 | 6.75 | 0.63 | 6.75 | 12.75 |
| • | • | TD-3 | 60A | 60A-600V | J | 6.38 | 6.75 | 0.63 | 6.75 | 12.75 |
| • | • | TE-1 | 100A | No Fuse | — | 4.75 | 8.50 | 0.63 | 6.50 | 12.50 |
| • | • | TE-2 | 100A | 100A-250V | H, K, R | 7.50 | 8.50 | 0.63 | 6.50 | 12.50 |
| • | • | TE-2 | 100A | 100A-600V | H, K, R | 9.50 | 8.50 | 0.63 | 6.50 | 12.50 |
| • | • | TE-2 | 100A | 100A-600V | J | 6.25 | 8.50 | 0.63 | 6.50 | 12.50 |
| • | • | TE-3 | 100A | 200A-600V | J | 13.75 | 8.50 | 0.63 | 6.50 | 12.50 |
| • | • | TF-1 | 200A | No Fuse | — | 5.50 | 11.75 | 0.63 | 5.12 | 11.12 |
| • | • | TF-2 | 200A | 200A-250V | H, K, R | 11.50 | 11.75 | 0.63 | 5.12 | 11.12 |
| • | • | TF-2 | 200A | 200A-600V | H, K, R | 14.00 | 11.75 | 0.63 | 5.12 | 11.12 |
| • | • | TF-2 | 200A | 200A-600V | J | 10.12 | 11.75 | 0.63 | 5.12 | 11.12 |
| • | • | TF-3 | 200A | 400A-600V | J | 14.50 | 11.75 | 0.63 | 5.12 | 11.12 |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 | col6 | col7 | col8 | col9 | col10 |
|---|---|---|---|---|---|---|---|---|---|
| Fits Enclosure Depth | Fits Enclosure Depth | Square D Type Number | Amp Rating | Space Occupied | Space Occupied | When A=60.13 P | When A=72.13 P | ||
| 60.13 | 72.13 | Square D Type Number | Amp Rating | Frame Size | L | M | N | When A=60.13 P | When A=72.13 P |
| • | • | RG-1 | 75A | GJL | 3.53 | 3.87 | 0.63 | 6.69 | 12.69 |
| • | • | RG-1 | 100A | GJL | 3.53 | 3.87 | 0.63 | 6.69 | 12.69 |
| • | • | RN-1 | 100A | FAL, FHL | 5.12 | 5.38 | 0.63 | 6.88 | 12.88 |
| • | • | RP-1 | 250A | KAL, KHL | 7.12 | 5.75 | 0.63 | 7.56 | 13.56 |
| • | RR-1 | 400A | LAL, LHL, Q4L | 7.62 | 8.88 | 0.63 | — | 9.25 |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 | col6 | col7 | col8 |
|---|---|---|---|---|---|---|---|
| Fits Enclosure Depth | Fits Enclosure Depth | Square D Type Number | Amp Rating | Fuse Clip | Fuse Class | Disconnect Height "X" | Disconnect Width "Y" |
| A=60.13 | A=72.13 | Square D Type Number | Amp Rating | Fuse Clip | Fuse Class | Disconnect Height "X" | Disconnect Width "Y" |
| P | P | Square D Type Number | Amp Rating | Fuse Clip | Fuse Class | Disconnect Height "X" | Disconnect Width "Y" |
| • | • | TCN-30 | 30A | No Fuse | — | 5.90 | 6.20 |
| • | • | TCF-30 | 30A | 30A-250V | H, K, R | 7.50 | 6.20 |
| • | • | TCF-33 | 30A | 30A-600V | H, K, R | 10.15 | 6.20 |
| • | • | TCF-33 | 30A | 60A-250V | H, K, R | 8.15 | 6.20 |
| • | • | TCF-33 | 30A | 30A-600V | J | 7.50 | 6.20 |
| • | • | TDN-60 | 60A | No Fuse | — | 5.90 | 6.20 |
| • | • | TDF-60 | 60A | 30A-600V | H, K, R | 10.15 | 6.20 |
| • | • | TDF-60 | 60A | 60A-250V | H, K, R | 8.15 | 6.20 |
| • | • | TDF-63 | 60A | 60A-600V | H, K, R | 10.65 | 6.20 |
| • | • | TDF-63 | 60A | 60A-600V | J | 7.50 | 6.20 |
| • | • | TEN-10 | 100A | No Fuse | — | 5.90 | 6.20 |
| • | • | TEF-10 | 100A | 100A-250V | H, K, R | 10.35 | 6.20 |
| • | • | TEF-10 | 100A | 100A-600V | H, K, R | 10.35 | 6.20 |
| • | • | TEF-10 | 100A | 100A-600V | J | 10.35 | 6.20 |
2UD, 2UDF & 2UDCP
| col1 | col2 | col3 | col4 | col5 | col6 | col7 |
|---|---|---|---|---|---|---|
| Fits Enclosure Depth | Fits Enclosure Depth | |||||
| A=60.13 | A=72.13 | Circuit Breaker | Circuit Breaker | |||
| P | P | Cable Type Switch | Amp Rating | Frame Type | Height "X" | Width "Y" |
| • | • | 9422 CGJ30 | 75A | GJL | 4.75 | 3.50 |
| • | • | 9422 CEJ30 | 100A | GJL | 4.75 | 3.50 |
| • | • | 9422 CFA30 | 100A | FAL,FHL | 6.00 | 4.50 |
| • | • | 9422 CKA30 | 250A | KAL,KHL | 8.00 | 4.50 |
| • | • | 9422 CLA30 | 400A | LAL,LHL,Q4L | 11.00 | 6.00 |